Inspections for the day of: Thursday, July 11, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02955 Final7/10/20197/11/20197/11/2019 3:51:04 PMPPASS
Please call Maddie on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co ok
MEC19-01558 Final7/10/20197/11/20197/11/2019 3:23:30 PMPPASS
code is 1027 Phone #: ###-#### Inspection requested via web by Joseph Profitt- final ok
MEC19-02831 Rough-in7/11/20197/11/20197/11/2019 2:38:29 PMPFAIL
Add. P test. Phone #: ###-#### Inspection requested via web by Joe Taylo- need approved man j onsite for inspection- need crawl completed- gas line into fire place needs secured- need to pan off all wood in R/A path and seal- need to fix 10" return above furenace inner liner showing- need 10 mil inert tape on gas penetration- remove hangers on csst to range and secure to floor and add nail plate bathroom side at floor
MEC19-02831 Pressure Test7/11/20197/11/20197/11/2019 2:36:01 PMAPART
Add. P test. Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass- need to see flue under test max 15lb gauge- will tag gas line when flue test witnessed
MEC19-02954 Final7/10/20197/11/20197/11/2019 2:09:48 PMPPASS
Please call Rob on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co ok
MEC19-02920 Rough-in7/11/20197/11/20197/11/2019 1:44:33 PMPFAIL
Joshua Phone #: ###-####- need uv protection on lineset outside at a/c location
MEC19-02212 Final7/11/20197/11/20197/11/2019 1:18:39 PMPPASS
Vinny is sup on-site: ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza-
MEC19-02952 Final7/10/20197/11/20197/11/2019 12:50:42 PMPPASS
Please contact owner Mark prior to arrival. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- final ok
MEC19-02957 Final7/10/20197/11/20197/11/2019 11:22:43 AMPPART
kitchen hood // James Phone #: ###-####- need all appliance set into place under class 1 hood- need air balance report onsite for all hoods- left side of north hood needs 18" ss panels installed in ceiling can not have ceiling tile within 18" went over with general onsite- need to uv protect arma flex on roof and seal water tight on line set penetration- call in when ready- dishwasher hood ok-
MEC18-05917 Final7/10/20197/11/20197/11/2019 11:19:05 AMPPART
partial final Phone #: ###-#### Inspection requested via web by Nicholas Paige- need to set up above ceiling temp test- need all appliances under class 1 hood set into place and flex gas piping hooked up- walked rest of job all good- few items for final
MEC19-01632 Final7/11/20197/11/20197/11/2019 9:53:40 AMAFAIL
Call me with any questions 208 631 6575 Inspection requested via web by jeff jedlick- need automatic timers installed on both units on energy star fans just has regular switch installed- need approved manual J onsite couldnt find any-
MEC19-02917 Rough-in7/10/20197/11/20197/11/2019 9:25:47 AMAPASS
cover inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- need to install access doors on both exhaust fan transitions to access electrical by final- call in final when ready
MEC19-02254 Final7/10/20197/11/20197/11/2019 8:38:15 AMAPASS
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
MEC19-02254 Card not on site to sign7/11/20197/11/20197/11/2019 8:38:01 AMPPASS
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- no card onsite to sign
MEC18-03813 Mec-Aging Inspection7/11/20197/11/20197/11/2019 8:05:12 AM CANC
MEC18-03813 DOC - Permit Expired7/11/20197/11/20197/11/2019 8:05:04 AMAPASS
no activity
MEC18-05725 Mec-Aging Inspection7/11/20197/11/20197/11/2019 8:04:09 AM FAIL
contractor shall schedule a flue test witness and correction- permit will expire next aging if no activity
MEC18-05728 Mec-Aging Inspection7/11/20197/11/20197/11/2019 8:03:03 AM FAIL
contractor shall schedule a flue test witness- permit will expire next aging if no activity
MEC18-03796 Mec-Aging Inspection7/11/20197/11/20197/11/2019 8:02:16 AM CANC
MEC18-03796 DOC - Permit Expired7/11/20197/11/20197/11/2019 8:02:01 AMAPASS
no activity