Inspections for the day of: Friday, July 12, 2019.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02831 Rough-in7/12/20197/12/20197/12/2019 3:57:35 PMPPASS
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor
MEC19-02831 Pressure Test7/12/20197/12/20197/12/2019 3:55:33 PMPPASS
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20 lb gas pass tagged meter location- 5lb flue pass
MEC19-02925 Final7/9/20197/12/20197/12/2019 3:37:42 PMPPASS
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC19-02832 Final7/11/20197/12/20197/12/2019 2:44:42 PMPPASS
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC19-02787 Pressure Test7/11/20197/12/20197/12/2019 1:37:21 PMPFAIL
This is ready for 3 inspections altogether including underground, pressure test and manu home connect final. Contact Buck at ###-#### with questions. Phone #: ###-#### Inspection requested via web by jamie berg- gas piping need approved manufactured flex gas line installed at side of mobile home can not be hard tie in- dont see a/c- will need to get inside unit to check coil and drains- lineset needs ran- retest system when flex connector is installed on gas line
MEC19-02973 Rough-in7/11/20197/12/20197/12/2019 1:19:57 PMPPASS
There is a lock box at the front door, code is 208 Phone #: ###-#### Inspection requested via web by Arcadio Martinez- R/I ok- will need to add 10" damper to supply line where sidewall register is by final- need approved prints onsite at final- contractor will be onsite for roof access at final
MEC19-02727 Rough-in7/11/20197/12/20197/12/2019 12:01:40 PMAFAIL
We need both 60lb an 20lb pressure tests please. If any questions please call Jeff Creek at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek
1- need to seal all supply and retun air registers-
2- supply duct in garage joists is below joists and insulated to r8
3- fresh air can not come from register can needs to be from plenum
4- b vent in garage at ceiling needs 1" clearance to wood and attic needs draft stop installed and firecaulked
5- house needs 2 gable end vents in attic to draw combustion air from attic for laundry room
6- framing needs completed around supply/return and b vent chase and draft stop installed around supply and return ducting
7- need fresh air to upstairs downstairs unit didnt see any
8- need nail plate on dryer duct at ceiling
9- south furnace model # does not match man j need to submit whats installed 10- R/A panning in garage needsremoved and ran in pipe and insulated to r6 unconditioned space-
left notice front window
MEC19-02958 Pressure Test7/11/20197/12/20197/12/2019 11:51:44 AMAPASS
60# on 3/4 line. 20# on manifold. Thanks. Phone #: ###-#### Inspection requested via web by Don Headrick
- 60lb gas pas- 20lb gas pass- will look at piping on other mechanical inspection
MEC19-01765 Final7/11/20197/12/20197/12/2019 11:35:43 AMAFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak-
1- need duct blast test completed and stickered
2- resubmit man j for approval of condenser brand used and have new approved man j onsite
3- b vent for 2 water heaters is undersized for 80000 btu need to reconfigure and install new
4
primay drain off coil to drain has backgrade
MEC19-01378 Final7/11/20197/12/20197/12/2019 11:26:36 AMAFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- need to resubmit man j condenser is different brand name and have approved man j onsite
2- need protection post installed in garage in front of supply duct where zone damper is
MEC19-02994 Final7/12/20197/12/20197/12/2019 11:07:57 AMAPART
Phone #: ###-#### Inspection requested via web by claude croy- need to add bath fan to permit and pay fee to final out
MEC19-02994 Rough-in7/12/20197/12/20197/12/2019 11:07:14 AMAPASS
Phone #: ###-#### Inspection requested via web by claude croy- R/I ok- need to add bath fan to permit and pay fee
MEC19-02727 Pressure Test7/11/20197/12/20197/12/2019 10:57:30 AMAPASS
We need both 60lb an 20lb pressure tests please. If any questions please call Jeff Creek at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek- 60lb gas pass tagged meter- 20lb gas pass- 5lb flue pass
MEC19-02181 Rough-in7/11/20197/12/20197/12/2019 9:58:00 AMAPASS
bathrooms and offices, Robert is your contact. Phone #: ###-#### Inspection requested via web by stan lillquist- 2 fire/smoke damper framong and clearances ok, ok for angles- seal on ducts in classrooms, offices and bathrooms ok- ok to cover- still need to look at linesets for a/cs and minisplits- ok for ceiling grid
MEC19-02971 Final7/11/20197/12/20197/12/2019 9:20:09 AMANR
Phone #: ###-#### Inspection requested via web by Robert J Mahler- per conversation with GC onsite- one fan needs move in master bath to accomendate grill- call in when all fans are ready and need ladder onsite to access attic
MEC19-02420 Final7/8/20197/12/20197/12/2019 9:08:32 AMAFAIL
Please call Dan on way to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- primary and secondary drains and arma flex need to be 6" clearance to single wall flue
MEC19-02938 Rough-in7/11/20197/12/20197/12/2019 8:46:00 AMAPASS
Mechanical Gas fireplace rough in inspection Phone #: ###-#### Inspection requested via web by Dan Otero
MEC19-01632 Final7/12/20197/12/20197/12/2019 8:36:23 AMAPASS
Call before you are on your way if possible for access 208 631 6575 Inspection requested via web by jeff jedlick
MEC19-02831 Rough-in7/11/20197/12/20197/12/2019 8:11:43 AMAFAIL
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor- need approved manual j onsite couldnt find one- few items went over with installer havent been fixed see yesterday notes
MEC19-02831 Pressure Test7/11/20197/12/20197/12/2019 8:10:39 AMAFAIL
With Rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- need flue under test- 20lb gas pass
MEC19-02841 Rough-in7/11/20197/12/20197/12/2019 8:10:09 AMAPASS
VINNIE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-02974 Rough-in7/11/20197/12/20197/12/2019 8:09:55 AMAPASS
VINNIE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC18-03877 Mec-Aging Inspection7/12/20197/12/20197/12/2019 7:56:49 AM CANC
MEC18-03877 DOC - Permit Expired7/12/20197/12/20197/12/2019 7:56:38 AMPPASS
work done under another permit
MEC19-02832 Final7/8/20197/12/20197/11/2019 7:34:20 AMPCANC
installer Travis ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt