MEC20-01939
| Final | 7/6/2020 | 7/8/2020 | 7/8/2020 3:23:25 PM | P | FAIL |
|
|
Please call Jon when on the way. Thank you!! Phone #: ###-#### Inspection requested via web by Denise Colin- drain/s off mini split need ran in 3/4" pvc with barbed fitting to flex drain and to approved location
|
MEC20-02690
| Final | 7/1/2020 | 7/8/2020 | 7/8/2020 2:24:25 PM | P | PASS |
|
|
INSTALLER DUSTIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-02790
| Rough-in | 7/8/2020 | 7/8/2020 | 7/8/2020 1:13:14 PM | P | FAIL |
|
|
Josh ###-####. Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need city approved prints onsite for inspection- seal on misc duct ok ok to insulate- need plenum rated insulation-
|
MEC20-01422
| Final | 7/7/2020 | 7/8/2020 | 7/8/2020 10:31:10 AM | A | FAIL |
|
|
Field super: DAryl Thomas gate code 1957 Phone #: ###-#### Inspection requested via web by Lisa Whitney- need duct blast completed- rest is good
|
MEC20-02403
| Final | 7/1/2020 | 7/8/2020 | 7/8/2020 9:38:10 AM | A | FAIL |
|
|
Please call ahead to Megan @ ###-#### when headed out to the residence Phone #: ###-#### Inspection requested via web by Sarah Small- condenser does not meet minimum 3 feet clearance to natural gas regulator- condenser needs turned 180 degrees to get electrical away from regulator-lineset will needs supported 3.5 inches above ground- will need locking caps on a/c service ports at final- recall in when condenser has been moved
|
MEC19-05423
| Mec-Aging Inspection | 7/8/2020 | 7/8/2020 | 7/8/2020 9:10:04 AM | | CANC |
|
|
permit expired
|
MEC19-05421
| Mec-Aging Inspection | 7/8/2020 | 7/8/2020 | 7/8/2020 9:09:35 AM | | FAIL |
|
|
contractor needs to schedule final inspection and make sure high temp silicone was used- only did pressure test previous inspection- permit will expire next aging if no activity
|
MEC19-05423
| DOC - Permit Expired | 7/8/2020 | 7/8/2020 | 7/8/2020 9:06:34 AM | A | PASS |
|
|
permit pulled at wrong address- permit expired
|
MEC20-02408
| Rough-in | 7/6/2020 | 7/8/2020 | 7/8/2020 8:56:37 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- arma flex needs all rips and tears fixed bare copper showing in wall at floor second floor- missing seal supply boot above back door
left notice
|
MEC20-02408
| Pressure Test | 7/6/2020 | 7/8/2020 | 7/8/2020 8:55:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-02409
| Rough-in | 7/6/2020 | 7/8/2020 | 7/8/2020 8:54:35 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- gas gauge wont zero out- flue test at zero- missing seal all supply boots first floor and line set needs adjusted one boot not laying flat against ceiling
left notice
|
MEC20-02409
| Pressure Test | 7/6/2020 | 7/8/2020 | 7/8/2020 8:51:40 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- gas gauge wont zero out- flue test at zero
|