Inspections for the day of: Wednesday, July 8, 2020.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-01939 Final7/6/20207/8/20207/8/2020 3:23:25 PMPFAIL
Please call Jon when on the way. Thank you!! Phone #: ###-#### Inspection requested via web by Denise Colin- drain/s off mini split need ran in 3/4" pvc with barbed fitting to flex drain and to approved location
MEC20-02690 Final7/1/20207/8/20207/8/2020 2:24:25 PMPPASS
INSTALLER DUSTIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
MEC20-02790 Rough-in7/8/20207/8/20207/8/2020 1:13:14 PMPFAIL
Josh ###-####. Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need city approved prints onsite for inspection- seal on misc duct ok ok to insulate- need plenum rated insulation-
MEC20-01422 Final7/7/20207/8/20207/8/2020 10:31:10 AMAFAIL
Field super: DAryl Thomas
gate code 1957 Phone #: ###-#### Inspection requested via web by Lisa Whitney- need duct blast completed- rest is good
MEC20-02403 Final7/1/20207/8/20207/8/2020 9:38:10 AMAFAIL
Please call ahead to Megan @ ###-#### when headed out to the residence Phone #: ###-#### Inspection requested via web by Sarah Small- condenser does not meet minimum 3 feet clearance to natural gas regulator- condenser needs turned 180 degrees to get electrical away from regulator-lineset will needs supported 3.5 inches above ground- will need locking caps on a/c service ports at final- recall in when condenser has been moved
MEC19-05423 Mec-Aging Inspection7/8/20207/8/20207/8/2020 9:10:04 AM CANC
permit expired
MEC19-05421 Mec-Aging Inspection7/8/20207/8/20207/8/2020 9:09:35 AM FAIL
contractor needs to schedule final inspection and make sure high temp silicone was used- only did pressure test previous inspection- permit will expire next aging if no activity
MEC19-05423 DOC - Permit Expired7/8/20207/8/20207/8/2020 9:06:34 AMAPASS
permit pulled at wrong address- permit expired
MEC20-02408 Rough-in7/6/20207/8/20207/8/2020 8:56:37 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- arma flex needs all rips and tears fixed bare copper showing in wall at floor second floor- missing seal supply boot above back door

left notice
MEC20-02408 Pressure Test7/6/20207/8/20207/8/2020 8:55:10 AMAPASS
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagged meter location- 5lb flue pass
MEC20-02409 Rough-in7/6/20207/8/20207/8/2020 8:54:35 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- gas gauge wont zero out- flue test at zero- missing seal all supply boots first floor and line set needs adjusted one boot not laying flat against ceiling

left notice
MEC20-02409 Pressure Test7/6/20207/8/20207/8/2020 8:51:40 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- gas gauge wont zero out- flue test at zero