Inspections for the day of: Wednesday, August 1, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03764 Final8/1/20188/1/20188/1/2018 4:12:36 PMPNR
Please call on way: Chris ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- still installing- will reschedule
MEC18-03673 Final8/1/20188/1/20188/1/2018 3:36:19 PMPPASS
Please call on way: Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- mini split a/c coil co ok
MEC18-01153 Final8/1/20188/1/20188/1/2018 2:53:44 PMPPASS
Bj. After 1 if possible. Makeup air is in the soffit Inspection requested via web by william kerwin- final ok- corrections made
MEC18-03630 Rough-in7/31/20188/1/20188/1/2018 2:36:47 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart- fireplace R/I ok
MEC18-03629 Rough-in7/31/20188/1/20188/1/2018 2:36:07 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
MEC18-00813 Final8/1/20188/1/20188/1/2018 2:09:26 PMPFAIL
Bj 573 0755 Inspection requested via web by william kerwin- need secondary drain ran- firecaulk all penetrations- need to fix insulation on supply and return
MEC18-03714 Final7/31/20188/1/20188/1/2018 1:29:50 PMPPASS
CUSTOMER PREFERS PM. PLEASE CALL THE CUSTOMER WHEN ON WAY: JASON ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace a/c coil co ok
MEC18-03564 Final7/30/20188/1/20188/1/2018 11:29:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC18-03374 Rough-in7/31/20188/1/20188/1/2018 11:14:37 AMAPASS
inspect duct before cabinets are installed Phone #: ###-#### Inspection requested via web by Tom Bond- R/I ok- will look at range duct on final after cabinets are installed
MEC17-04181 Final7/31/20188/1/20188/1/2018 10:04:31 AMAPART
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- need to run hard pipe on hood thru appliance- need approved drawing of engineering room onsite- Brad will get it
MEC18-02270 Final7/31/20188/1/20188/1/2018 9:30:53 AMAFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- no access- all locked up
MEC18-03738 Final8/1/20188/1/20188/1/2018 9:24:02 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC18-03406 Rough-in7/31/20188/1/20188/1/2018 9:21:44 AMAPART
Rough in in office area - Duct Sealing
Contact Rich Beckstead ###-#### Phone #: ###-#### Inspection requested via web by Beka Hereau- seal on first and second floor ok- ok to insulate- still need RFI issued on plenum walls- do not cover any plenum walls at this time- plenums must use plenum rated materials
MEC17-04980 Mec-Aging Inspection8/1/20188/1/20188/1/2018 9:18:19 AM FAIL
needs final inspection called in