Inspections for the day of: Friday, August 23, 2019.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-03602 Pressure Test8/23/20198/23/20198/23/2019 3:48:24 PMPPASS
Inspection requested via web by Aaron Alandt- 20lb gas pass tagged meter location
MEC19-03618 Final8/19/20198/23/20198/23/2019 3:18:30 PMPPASS
Please call the Owner, Jason at ###-#### with a 30 minute heads up arrival time. Thank you! Phone #: ###-#### Inspection requested via web by David or K Cole- furnace a/c coil co ok
MEC19-03783 Rough-in8/22/20198/23/20198/23/2019 2:40:03 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need approved man j onsite for inspection
MEC19-02063 Rough-in8/22/20198/23/20198/23/2019 2:13:43 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brad Knapton-
1- need to submit man j to city for approval and have approved man j onsite for inspection
2- crawl needs completedon R/I and air balance will need to be done on new ducting at final
3- need to add 1 exhaust fan and duct work to permit and pay fee
4- no gas test found

left notice
MEC19-03677 Rough-in8/22/20198/23/20198/23/2019 1:45:25 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
1- need to finish insulation on R/A in attic bare metal showing
2- arma flex thru exterior penetration needs fixed bare copper showing
3- need approved man j onsite
4- wye branch in attic has tape on it not maintaining insulation value 12x8 to 8x6 by R/A can in living room

left notice
MEC19-03677 Pressure Test8/22/20198/23/20198/23/2019 1:42:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location
MEC19-03767 Final8/22/20198/23/20198/23/2019 1:07:48 PMPPASS
Please call Jeremy on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
MEC19-03557 Final8/21/20198/23/20198/23/2019 12:41:45 PMPFAIL
Please call Tracy prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c coil co ok- need right size fuses in disconnect has 35 needs 25 max
MEC19-03598 Final8/22/20198/23/20198/23/2019 11:30:29 AMAPASS
Homeowner Pam Brassfield ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c coil co ok
MEC19-02496 Conference8/22/20198/23/20198/23/2019 11:12:43 AMADONE
Gas Fireplace stone framing consult. Melinda Hughes ###-#### Phone #: ###-#### Inspection requested via web by Melinda Hughes- other mech contractor will pull permit for fireplace and its ok to install hardy board over existing opening per fireplace company- will need fireplace inspection completed before any rock/stone can be installed- ok for hardy board
MEC19-03418 Final8/23/20198/23/20198/23/2019 10:44:38 AMPCANC
Call Robert in route to inspection ###-#### Phone #: ###-#### >> Inspection requested via web by Justin Osterhout Inspection cancelled from web by: Justin Osterhout
MEC19-03778 Final8/22/20198/23/20198/23/2019 10:21:38 AMAPASS
home owner would like 10:00 call before coming Phone #: ###-#### Inspection requested via web by Kim Lithander- a/c coil co ok
MEC19-03552 Final8/16/20198/23/20198/23/2019 9:47:24 AMAPASS
please call our lead installer Jonah 30-40 mins prior so he can have flue under pressure and ready when you arrive Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co ok- 5lb flue pass
MEC19-03785 Rough-in8/23/20198/23/20198/23/2019 9:31:42 AMAFAIL
Need partial Rough-in for dryer vent on back wall. Need ok to cover. Inspection requested via web by Floyd Floyd Peek- dryer vent ran in 3.5" wall- wall needs firred out dryer has to maintain 4" round- duct outside of framing
MEC19-03586 Final8/22/20198/23/20198/23/2019 8:37:40 AMAFAIL
Please call the customer, Tim, when on way at ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- flue on furnace in crawl needs grade from furnace to chimney trapped over piping
MEC19-02776 Final8/23/20198/23/20198/23/2019 8:21:04 AMAPASS
final ok- card signed
MEC19-02181 Final8/23/20198/23/20198/23/2019 8:19:51 AMAPASS
Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- final ok- card signed
MEC19-00137 Mec-Aging Inspection8/23/20198/23/20198/23/2019 7:50:10 AM FAIL
contractor needs to schedule inspection with homeowner- permit will expire next aging if no activity