Inspections for the day of: Wednesday, August 28, 2019.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-03648 Final8/21/20198/28/20198/28/2019 4:04:42 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace gas piping co ok-
MEC19-03648 Pressure Test8/21/20198/28/20198/28/2019 4:04:05 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass whole system tagged meter location- 5lb flue pass-
MEC19-03784 Final8/28/20198/28/20198/28/2019 4:02:34 PMPPASS
MEC19-03784 Conference8/27/20198/28/20198/28/2019 4:01:59 PMPPASS
Inspection requested via web by Mike Deleve- 20lb gas pass whole system- tagged meter location
MEC19-02063 Rough-in8/28/20198/28/20198/28/2019 3:47:46 PMPPART
OK to cover pending man j- will need another R/I inspection completed as soon as man j approved and onsite
MEC19-00266 Final8/28/20198/28/20198/28/2019 2:58:21 PMPCANC
Jake is the contact Phone #: ###-#### Inspection requested via web by stan lillquist0 see R/I notes-
MEC19-00266 Rough-in8/28/20198/28/20198/28/2019 2:57:58 PMPFAIL
Jake is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- unit heater fluing needs to be minimum 5 feet from paraphet wall flues installed are all 4 feet ish- on sheet m-3 note 13 gives dimensions per engineer to maintain 5 feet-
MEC19-03846 Pressure Test8/27/20198/28/20198/28/2019 2:32:18 PMPFAIL
Phone #: ###-#### Inspection requested via web by Nick Drake-- 2# system needs tested on 100lb gauge at 60psi- need to added other mechanical to permit by R/I ie range, bath fans, any other mechanical being installed and pay fee
MEC19-03781 Final8/22/20198/28/20198/28/2019 2:01:09 PMPPASS
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC19-03785 Rough-in8/28/20198/28/20198/28/2019 1:32:24 PMPFAIL
Inspection requested via web by Floyd Floyd Peek- no access locked up
MEC19-03244 Final8/28/20198/28/20198/28/2019 1:27:08 PMPCANC
Charle Phone #: ###-####- should have been r/i inspection- call in final when ready
MEC19-03244 Rough-in8/28/20198/28/20198/28/2019 1:26:42 PMPPASS
Charle Phone #: ###-####- fireplace, bath ex and ducting in crawl ok- ok to cover
MEC19-03780 Final8/22/20198/28/20198/28/2019 12:38:22 PMPCANC
Call ahead to Mark Hatfield @ ###-#### Phone #: ###-#### Inspection requested via web by Nicole Smith- per phone call with Mark rescheduled for 9-5-19 in pm
MEC19-02512 Rough-in8/28/20198/28/20198/28/2019 12:30:29 PMPPART
Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist- column 4 thru 8 insulation and registers ok- ok for sheetrock this area only- seal on duct column 2 thru 4 supply and r/a ok- ok to insulate- still need to look at exhaust ducting
MEC19-00869 Final8/27/20198/28/20198/28/2019 11:28:31 AMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney- final ok
MEC19-03845 Final8/27/20198/28/20198/28/2019 10:54:05 AMACANC
Please contact Joey @ ###-#### to coordinate access. Phone #: ###-#### Inspection requested via web by Joey Hickman- per phone with Joey will reschedule added exhaust to scope of work needs vented-
MEC19-03817 Final8/26/20198/28/20198/28/2019 10:44:06 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- electric furnace heat pump coil ok
MEC19-03850 Final8/27/20198/28/20198/28/2019 10:10:07 AMAPASS
Please call client David prior to arrival. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- a/c coil co ok
MEC19-03803 Rough-in8/27/20198/28/20198/28/2019 9:42:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Brian Preece- fireplace R/I ok- need to turn gas valve 180 degree for easy access to turn off/on by final
MEC19-03851 Rough-in8/27/20198/28/20198/28/2019 9:13:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- fireplace R/I ok
MEC19-03814 Pressure Test8/28/20198/28/20198/28/2019 8:28:15 AMAPASS
Please call Carroll when heading to her home ###-#### Inspection requested via web by Floyd Floyd Peek- 20lb gas pass to range
MEC19-03814 Final8/28/20198/28/20198/28/2019 8:27:55 AMAPASS
Please call Carroll when heading to her home ###-#### Inspection requested via web by Floyd Floyd Peek
MEC19-00273 Mec-Aging Inspection8/28/20198/28/20198/28/2019 7:53:17 AM FAIL
contractor needs to schedule inspection if works complete- permit will expire next aging if no activity
MEC19-03754 Final8/27/20198/28/20198/28/2019 7:52:07 AMACANC
PLEASE CALL ROBERT WHEN 30 MINS IN ROUTE Phone #: ###-#### >> Inspection requested via web by Rick Montgomery Inspection cancelled from web by: Rick Montgomery