Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-02508 Final8/8/20188/8/20188/8/2018 3:53:56 PMPPASS
MEC18-02507 Final8/8/20188/8/20188/8/2018 3:53:31 PMPPASS
MEC18-01799 Final8/8/20188/8/20188/8/2018 3:23:27 PMPPASS
final - call dave with any questions Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
MEC18-03188 Rough-in8/8/20188/8/20188/8/2018 3:06:49 PMPPASS
Please contact Homeowner in advanced to let know when headed that direction- Teresa @ 208.562.9295

Garage Code: 82840 Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
MEC18-03406 Rough-in8/8/20188/8/20188/8/2018 2:35:54 PMPFAIL
Request for cover upstairs and downstairs bathroom Phone #: ###-#### Inspection requested via web by Beka Hereau- need to finish exhaust duct thru roof and seal- need to seal oval to round off fan and seal both first and second floors and attach with screws- need tranfers first floor thats missing and register installed- talked with installer onsite- recall in when ready
MEC18-03816 Final8/7/20188/8/20188/8/2018 1:56:25 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- RTU final ok
MEC18-02578 Final8/8/20188/8/20188/8/2018 1:28:29 PMPPASS
Please contact Jasper with any questions. Thanks! Phone #: ###-#### Inspection requested via web by Ted Dumont
MEC18-03629 Conference8/7/20188/8/20188/8/2018 11:37:09 AMAPASS
Blast witness @ 11:30 Phone #: ###-#### Inspection requested via web by Randy Hart- duct blast test pass
MEC18-00901 Conference8/7/20188/8/20188/8/2018 11:11:02 AMADONE
Jordan Phone #: ###-####- discussed range ducting, exhaust fan ducting and supply duct in base and main level
MEC18-03733 Final8/7/20188/8/20188/8/2018 9:57:51 AMAPASS
Phone #: ###-#### Inspection requested via web by Ron Arnold- furnace a/c coil ok
MEC18-03737 Pressure Test8/7/20188/8/20188/8/2018 9:23:37 AMAFAIL
900 to 930am- 208- ###-####- gauge wont zero out- at no point can 1 shut off valve have gas on one side and air on other- need to install 2 shutoff valves with open tee between them and use as a sediment trap- leave sediment trap out until after pressure test is completed
MEC18-02475 Final8/6/20188/8/20188/8/2018 8:43:49 AMAPASS
Duct Blast 8:30 am Phone #: ###-#### Inspection requested via web by Debbie Marino- final ok
MEC18-02475 Conference8/6/20188/8/20188/8/2018 8:42:39 AMAPASS
Duct Blast 8:30 am Phone #: ###-#### Inspection requested via web by Debbie Marino- duct blast test pass
MEC17-05191 Mec-Aging Inspection8/8/20188/8/20188/8/2018 8:12:21 AM FAIL
need flu test scheduled and correction fixed and inspection called in
MEC17-05182 Mec-Aging Inspection8/8/20188/8/20188/8/2018 8:11:30 AM FAIL
needs called in for inspection by homeowner