Inspections for the day of: Tuesday, September 24, 2019.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04088 Conference9/23/20199/24/20199/24/2019 4:12:13 PMPDONE
Please call 30 minutes before anticipated arrival. Phone number is area code ###-#### Phone #: ###-#### Inspection requested via web by David Compton- discussed fireplace installation per instructions
MEC19-04127 Pressure Test9/23/20199/24/20199/24/2019 3:52:28 PMPCANC
Call Kurtis ###-#### to meet you, 15 to 20 minute heads up if possible, house is vacant, gas pressure test on back patio at meter, fan vents have been roughed in Phone #: ###-#### Inspection requested via web by John Bertram- 20lb gas pass whole system
MEC19-04127 Rough-in9/24/20199/24/20199/24/2019 3:51:50 PMPPASS
Call Kurtis ###-#### to meet you, 15 to 20 minute heads up if possible, house is vacant, gas pressure test on back patio at meter, fan vents have been roughed in Phone #: ###-#### Inspection requested via web by John Bertram- R/I ok- need to insulate all bare metal in garage, attic and crawl space on new ducting by final- dryer vent wall needs firred out- need insulation shield on water heater/furnace b vent with 1" clearance in attic- condensate drain needs to be 3/4" pvc to outside
MEC19-03902 Final9/24/20199/24/20199/24/2019 3:26:20 PMPPASS
Robert Phone #: ###-####- furnace a/c coil co ok
MEC19-03902 Rough-in9/24/20199/24/20199/24/2019 3:25:56 PMPCANC
Robert Phone #: ###-####
MEC19-03986 Rough-in9/24/20199/24/20199/24/2019 2:58:08 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC19-03986 Pressure Test9/24/20199/24/20199/24/2019 2:57:46 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass- tagged meter location
MEC19-04080 Final9/24/20199/24/20199/24/2019 2:15:49 PMPPASS
final - call dave Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
MEC19-02586 Final9/23/20199/24/20199/24/2019 2:06:05 PMPPASS
please Joe call 30 min prior Phone #: ###-#### Inspection requested via web by Andrea Grigsby- a/c coil co ok
MEC19-04246 Rough-in9/24/20199/24/20199/24/2019 1:52:05 PMPPART
bathroom fan // Albert Phone #: ###-####- bath fan ok- ok to sheetrock- need light test scheduled for grease duct- need hood clearances
MEC19-03277 Final9/23/20199/24/20199/24/2019 1:38:00 PMAFAIL
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:30 AM . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette- flue not holding pressure
MEC17-03568 Conference9/24/20199/24/20199/24/2019 1:35:33 PMPDONE
Barbara Phone #: ###-####- discussed gas piping,, exhaust fans electric heater dryer duct- exhaust and dryer ducting ok- need installation instruction on fireplace to see if ul listed
MEC19-02864 Rough-in9/24/20199/24/20199/24/2019 12:27:51 PMPPASS
rough Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- insulation ok- ok for grid
MEC19-02375 Final9/23/20199/24/20199/24/2019 12:15:44 PMPPASS
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- final ok- card signed
MEC19-04214 Rough-in9/23/20199/24/20199/24/2019 11:21:34 AMAPART
cover inspection - call luke Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on ducts above 2 bsthrooms ok- ok to insulate- recall in when insulated before sheetrock- initialed approved prints
MEC19-01919 Final9/23/20199/24/20199/24/2019 11:15:19 AMAPART
Steve is the contact, Air balance sent via email. Phone #: ###-#### Inspection requested via web by stan lillquist- equipment under class 1 hood doesnt meet clearances will need relocated- Rest is good- Steve knows along with general contractor- temp occupancy ok- Steve will coordinate with me
MEC19-01412 Final9/24/20199/24/20199/24/2019 11:13:56 AMAPART
need to secure gas piping to supports on roof- equipment under class 1 hood doesnt meet clearances will need relocated- temp occupancy ok- will look at this on other mech final
MEC19-03146 Final9/24/20199/24/20199/24/2019 11:12:40 AMAPART
equipment under class 1 hood doesnt meet clearances- talked with general onsite- class 1 curb has vents covered- temp occupancy ok- will look at on other mech final
MEC19-04206 Rough-in9/23/20199/24/20199/24/2019 9:53:58 AMAPART
Greg Phone #: ###-####- Ok to sheetrock- ducting only in crawl- will look at crawl duct on next inspection when ducting installed- recall in when ready
MEC19-03642 Rough-in9/23/20199/24/20199/24/2019 9:31:07 AMAPASS
coil / ac / lineset / condensate drain line Phone #: ###-#### Inspection requested via web by Joseph Profitt- R/I ok- need to level condenser pad by final
MEC19-03642 Pressure Test9/23/20199/24/20199/24/2019 9:30:07 AMAPASS
underground gas line Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass- ok to backfill underground- tagged meter location
MEC19-03906 Rough-in9/23/20199/24/20199/24/2019 9:15:03 AMAPASS
Kai ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC19-04232 Pressure Test9/23/20199/24/20199/24/2019 8:58:06 AMAPASS
Gage at gas meter in front of shop.
Gates open Phone #: ###-#### Inspection requested via web by anthony allen- 60lb gas pass from meter thru garage and underground to pool heater shed- will need to see regulators installed and operational at final-
MEC19-02641 Final9/20/20199/24/20199/24/2019 8:20:20 AMAPASS
Please call Amanda 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby- a/c coil co ok