Inspections for the day of: Thursday, September 26, 2019.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04070 Rough-in9/26/20199/26/20199/26/2019 2:31:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz- R/I ok
MEC19-04069 Rough-in9/26/20199/26/20199/26/2019 2:30:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz- R/I ok
MEC19-04068 Rough-in9/26/20199/26/20199/26/2019 2:29:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz- R/I ok
MEC19-04067 Rough-in9/26/20199/26/20199/26/2019 2:28:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz- R/I ok
MEC19-04091 Rough-in9/26/20199/26/20199/26/2019 1:52:17 PMPFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley
1- missing transfer register in bedroom 2 and 4
2- 2nd drain needs ran
3- need range ducting installed ??
4- need nail plate bedroom 3 at ceiling on 3/4" pvc drain
5- b vent for water heater at roof needs 1" clearance to combustibles
6- need to insulate register can R/A where 6" outside air duct was removed
7- need to insulate outside air filter box in attic

left correction n otice front window
MEC19-04091 Pressure Test9/26/20199/26/20199/26/2019 1:48:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass- tagged meter location
MEC19-04115 Rough-in9/26/20199/26/20199/26/2019 1:48:25 PMPFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley-
1- need to insulate outside air filter box in attic
2- supply register in master bedroom just hanging in ceiling
3- 6" fresh/outside air can not come from register can needs tied into R/A plenum at furnace
4- need 4" b vent 90 at furnace location in attic

left notice front entry window
MEC19-04115 Pressure Test9/26/20199/26/20199/26/2019 1:45:57 PMPPASS
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass
MEC19-04245 Final9/26/20199/26/20199/26/2019 1:36:46 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-03277 Final9/25/20199/26/20199/26/2019 11:35:05 AMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:30 . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok- 5lb flue test pass
MEC19-04134 Pressure Test9/26/20199/26/20199/26/2019 11:23:46 AMPCANC
Please call Dave when on the way! ###-#### Thank you! Phone #: ###-#### >> Inspection requested via web by Rick Borg Inspection cancelled from web by: Rick Borg
MEC19-04134 Final9/26/20199/26/20199/26/2019 11:23:44 AMPCANC
Please call Dave to ensure install is complete. Thank you! ###-#### Phone #: ###-#### >> Inspection requested via web by Rick Borg Inspection cancelled from web by: Rick Borg
MEC19-04246 Conference9/26/20199/26/20199/26/2019 11:14:18 AMPDONE
Phone #: 2088718789 >> Inspection requested via mobile web by Albert- exterior wall framing ok- discussed height of hood and stainless steel panels on wall
MEC19-03839 Final9/19/20199/26/20199/26/2019 10:42:42 AMAPASS
Call Lindsey in route to inspection ###-####-- she is available after 9-930
Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok
MEC19-03775 Final9/25/20199/26/20199/26/2019 10:13:40 AMAPASS
Final Inspection - Contact Buck ###-#### Phone #: ###-#### Inspection requested via web by jamie berg- final ok
MEC19-01412 Final9/25/20199/26/20199/26/2019 9:52:09 AMAPASS
please call prior to arriving for access
Phone #: ###-#### Inspection requested via web by Nicholas Paige- final ok
MEC19-03121 Final9/25/20199/26/20199/26/2019 9:39:41 AMAPASS
Please contact the Office or Shivani Sami directly at ###-#### for access to apt # 3001-201. Thank you! Phone #: ###-#### Inspection requested via web by David or K Cole- furnace coil co ok
MEC18-05886 Pressure Test9/25/20199/26/20199/26/2019 9:21:51 AMAPASS
Brad Phone #: ###-####- 20lb gas pass- need 3/4" pvc drain ran to washer location from furnace with condensate pump by final- air balance to- R/I ok
MEC19-04254 Pressure Test9/24/20199/26/20199/26/2019 9:04:31 AMAPASS
PLEASE CONTACT OWNER PAUL PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- 20lb gas pass
MEC19-04254 Final9/26/20199/26/20199/26/2019 9:04:04 AMAPASS
PLEASE CONTACT OWNER PAUL PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
MEC19-04233 Final9/24/20199/26/20199/26/2019 8:40:14 AMAFAIL
Please call Steve prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- condensate needs routed to approved location- talked with Josh about this
MEC19-03450 Final9/24/20199/26/20199/24/2019 3:39:31 PMPCANC
Please contact homeowner, David, at number provided with ETA when you are on your way, just to ensure he is home. Thanks! If you have any trouble, call Alyssa at ###-####. Phone #: ###-#### >> Inspection requested via web by Alyssa Cromwell Inspection cancelled from web by: Alyssa Cromwell
MEC19-03277 Final9/24/20199/26/20199/24/2019 3:30:31 PMACANC
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:30. Contact for Right Now is Mary ###-####
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette