Inspections for the day of: Tuesday, September 3, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02747 Final8/30/20199/3/20199/3/2019 3:53:10 PMPPASS
Philip Phone #: ###-####- furnace a/c coil co ok
MEC19-03932 Rough-in9/3/20199/3/20199/3/2019 3:52:13 PMPNR
add p test Phone #: ###-#### Inspection requested via web by Joe Taylor-
MEC19-03932 Pressure Test9/3/20199/3/20199/3/2019 3:48:47 PMPPASS
add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass-- 5lb flue pass
MEC19-02830 Final9/3/20199/3/20199/3/2019 3:46:21 PMPCANC
Joe Phone #: ###-####- furnace prepped for painting- recall in when plastic removed
MEC19-03931 Final9/3/20199/3/20199/3/2019 3:07:23 PMPFAIL
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need access to roof- riser door locked up
MEC18-05977 Final9/3/20199/3/20199/3/2019 2:29:33 PMPPASS
garage 2000 Phone #: ###-#### Inspection requested via web by ted roy- both units ok
MEC19-03652 Rough-in9/3/20199/3/20199/3/2019 1:50:20 PMPPASS
light test - call Luke Phone #: ###-#### Inspection requested via web by Brandon Sorensen- light test pass- ok for 1st and 2nd layer fire wrap
MEC19-03211 Rough-in9/3/20199/3/20199/3/2019 1:01:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
MEC19-03845 Final9/2/20199/3/20199/3/2019 12:19:29 PMPPASS
Call for Joey got access. Phone #: ###-#### Inspection requested via web by Joey Hickman
MEC19-03911 Final8/30/20199/3/20199/3/2019 11:11:38 AMAPASS
Client is available after 2:30 anytime.
If prior to that time, please call 30 minutes in advance so client can meet you there. POC Christina Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co ok
MEC18-03082 Final8/30/20199/3/20199/3/2019 10:27:10 AMAPASS
garage sliding door is unlocked Phone #: ###-#### Inspection requested via web by Randy Hart
MEC19-03752 Final8/29/20199/3/20199/3/2019 10:13:00 AMAPASS
call in advance Phone #: ###-#### Inspection requested via web by Nicholas Paige
MEC19-03908 Final8/30/20199/3/20199/3/2019 9:27:30 AMAFAIL
Phone #: ###-####- class 2 hoods shall over hang 6" minimum all sides of equipment- need to install duct work per prints missing registers- is exhaust duct from class 2 hood SS per prints- will need air balance report also
MEC19-03852 Rough-in8/30/20199/3/20199/3/2019 9:00:29 AMAPART
Jake is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist- seal on exhaust, supply and R/A ok- ok to insulate- needs to see exhaust fans installed before cover- need to verify flex connectors at unit on supply and R/A per drawings
MEC19-03687 Final9/2/20199/3/20199/3/2019 8:41:24 AMAFAIL
Retro fit on existing home. Phone #: ###-#### Inspection requested via web by Chris Gonzalez- need to insulate R/A bare metal in garage to R-6 excluding filter access door- need to provide co detector near bedrooms- need right size fuses in a/c disconnect- need sediment trap between gas shut off and appliance
MEC18-05168 Mec-Aging Inspection9/3/20199/3/20199/3/2019 8:09:34 AM CANC
MEC18-05168 DOC - Permit Expired9/3/20199/3/20199/3/2019 8:09:27 AMAPASS
no activity
MEC18-05164 Mec-Aging Inspection9/3/20199/3/20199/3/2019 8:08:48 AM CANC
MEC18-05164 DOC - Permit Expired9/3/20199/3/20199/3/2019 8:08:41 AMAPASS
no activity
MEC17-05182 Mec-Aging Inspection9/3/20199/3/20199/3/2019 8:08:08 AM CANC
needs called in for R/I inspection