MEC19-03945
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 3:52:00 PM | P | PASS |
|
|
INSTALLER SCOTT ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
|
MEC19-03510
| Rough-in | 9/5/2019 | 9/5/2019 | 9/5/2019 3:13:43 PM | P | FAIL |
|
|
Joe Phone #: ###-#### 1- fresh air can not come from register can route to plenum at furnace 2- insulation shield garage laying against b vent 3- secure outside air duct away from b vent in chase 2nd floor
left sticker front window
|
MEC19-03510
| Pressure Test | 9/5/2019 | 9/5/2019 | 9/5/2019 3:12:05 PM | P | PASS |
|
|
Joe Phone #: ###-####- 20lb gas pass- 5lb flue pass- equipment will set on final
|
MEC19-03932
| Rough-in | 9/5/2019 | 9/5/2019 | 9/5/2019 3:11:15 PM | P | PASS |
|
|
Joe Phone #: ###-####- R/I ok
|
MEC19-02477
| Final | 9/5/2019 | 9/5/2019 | 9/5/2019 3:10:01 PM | P | PASS |
|
|
|
MEC19-03950
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 2:38:21 PM | P | PASS |
|
|
Please call Dave on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok- 5lb flue pass
|
MEC19-03840
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 11:20:50 AM | A | PASS |
|
|
please call darrel for entry 208 392 5886 Phone #: ###-#### Inspection requested via web by Jeremy lehosit
|
MEC19-02478
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 10:46:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rachael Moore- gas piping final ok- will install unit heaters at later date
|
MEC19-03636
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 10:16:25 AM | A | PASS |
|
|
The unit should be locked but there is also a lockbox code REB Phone #: ###-#### Inspection requested via web by Joseph Profitt- a/c coil gas piping ok
|
MEC19-01679
| Rough-in | 9/4/2019 | 9/5/2019 | 9/5/2019 9:57:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- Area B only 6 class rooms seal ok- ok for insulation all 6 classrooms area B only- approved drawings onsite
|
MEC19-01210
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 9:14:09 AM | A | PASS |
|
|
Ductblast witness @ 9AM per Brian City inspector AC: 2018 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- duct blast test pass
|
MEC19-03750
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 8:36:54 AM | A | PASS |
|
|
830am- 208- ###-####- electric furnace a/c coil ok
|
MEC19-03932
| Rough-in | 9/4/2019 | 9/5/2019 | 9/5/2019 8:22:02 AM | A | FAIL |
|
|
Joe Phone #: ###-#### 1- dryer vent outside wall- need to remove horzontal framing and reroute inside of wall 2- exhaust 1st floor needs framing opened up where enters attic in garage duct pinched
left correction notice front window
|
MEC19-02841
| Final | 9/4/2019 | 9/5/2019 | 9/5/2019 8:14:46 AM | A | PASS |
|
|
VINNIE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC19-03780
| Final | 8/28/2019 | 9/5/2019 | 9/5/2019 12:00:00 AM | P | CANC |
|
|
Mark ###-####
|
MEC19-02841
| Rough-in | 9/4/2019 | 9/5/2019 | 9/4/2019 5:29:47 PM | A | CANC |
|
|
VINNIE ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza
|