Inspections for the day of: Friday, December 15, 2017.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03096 ELE-Aging Inspection12/15/201712/15/201712/21/2017 10:55:12 AM PASS
Sign present with disconnect on left side.
ELE17-02033 Final12/15/201712/15/201712/15/2017 1:35:32 PMPPASS
Garage code 0813 Phone #: ###-#### Inspection requested via web by cal crosby Ok final.
ELE17-04005 Permanent Service12/15/201712/15/201712/15/2017 12:46:17 PMPPASS
Inspect Meter pedestal for Boise City Street Light. Phone #: ###-#### Inspection requested via web by Chase Sessions p/s u/g n ok. Talked to contractor and mentioned to him that AFC is needed for final.
ELE17-01794 Final12/14/201712/15/201712/15/2017 12:13:56 PMAPASS
Homeowners will be home all morning. If you have any questions please call Luke ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clay Morgan Ok final. GFI test on floor heat functions properly.
ELE07-02791 ELE-Aging Inspection12/15/201712/15/201712/15/2017 11:42:56 AM DONE
Please set up a time with homeowner and schedule a final inspection.
ELE13-02985 Final12/15/201712/15/201712/15/2017 11:41:26 AMPPASS
Looked at at 1140 on 12/15/17. Labeling at meters present. Ok final.
ELE17-02780 Electrical Rough-In12/15/201712/15/201712/15/2017 10:58:31 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M Ok cover ceiling throughout.
ELE17-02024 Final12/14/201712/15/201712/15/2017 9:31:56 AMAPASS
Shane Phone #: ###-#### Ok final. Switch used for 240v heater came with unit from manufacturer.
ELE17-03845 Electrical Rough-In12/14/201712/15/201712/15/2017 9:07:42 AMAPASS
It''s wide open, please call Tony with any questions. Thank You! Phone #: ###-#### Inspection requested via web by Clay Morgan Ok cover. Permanent service not called in. I added a p/s inspection.
ELE17-03845 Permanent Service12/15/201712/15/201712/15/2017 9:06:55 AMPPASS
p/s u/g n ok
ELE17-03559 Electrical Rough-In12/15/201712/15/201712/15/2017 9:06:12 AMANR
Please call or text me at ###-#### and I can be there in 15 minutes. Thanks, Jim Hinen Inspection requested via web by James Hinen
1. Wires need to be stapled 1-1/4 away from face of studs.
2. Connectors needed for recess cans.
3. Wires for recess cans need to be secured to studs.
4. Grounds and neutrals need to be made up at all box locations.
ELE17-04028 Electrical Rough-In12/13/201712/15/201712/15/2017 8:30:32 AMAPASS
As early as possible would be appreciated. Thanks. Phone #: ###-#### Inspection requested via web by Matt Frey Ok cover 2 baths, closet and utility area. Needs ground screw for dryer outlet and KO seal. Also told Matt he needed to add an outlet between sinks in mstr bath as they are installing one outlet inside medicine cabinet left of vanity. These items can be checked when floor heat is inspected.
ELE17-04185 Final12/14/201712/15/201712/15/2017 7:38:45 AMAPASS
Darren ###-#### p/s u/g n ok. Looked at on 12/14/17. Talked to Darren, electrician, conduit running on top of building is being changed to a different layout.