Inspections for the day of: Tuesday, April 7, 2020.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-01214 Final4/7/20204/7/20204/7/2020 2:08:34 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Ok final.
ELE20-01176 Final4/7/20204/7/20204/7/2020 1:06:11 PMPPASS
shed// Joe *cleared* Phone #: ###-#### Ok final
ELE19-00947 Final4/6/20204/7/20204/7/2020 12:13:12 PMPPART
Partial final Phone #: ###-#### Inspection requested via web by Andy Chambers 2A classrooms.
ELE20-01172 Final4/6/20204/7/20204/7/2020 11:33:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Tom Jenkins Ok final.
ELE20-00494 Final4/7/20204/7/20204/7/2020 11:11:54 AMPPASS
Front door will be unlocked Phone #: ###-#### Inspection requested via web by Kevin Heideman Ok final.
ELE20-01204 Final4/6/20204/7/20204/7/2020 11:11:14 AMAPASS
The school is open after 9 a.m.. Final inspection please. Thank you, Phone #: ###-#### Inspection requested via web by Kyle Lott Ok final. Existing power used to power new card reader.
ELE20-00878 Final4/6/20204/7/20204/7/2020 10:36:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Tom Jenkins Ok final. 2 pole 20a OCP for rooftop minisplit.
ELE20-01217 Electrical Rough-In4/6/20204/7/20204/7/2020 10:01:34 AMAPASS
Phone #: ###-#### Inspection requested via web by William Andrews Ok cover
ELE20-01214 Permanent Service4/7/20204/7/20204/7/2020 9:36:50 AMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk p/s u/g n ok
ELE20-01219 Permanent Service4/6/20204/7/20204/7/2020 8:33:26 AMAFAIL
Dedicated well circuit needs inspected for a separate service to be installed. There is an existing service at the home. This is a second service location for the well using the same physical street address. Dustin ###-#### Phone #: ###-#### Inspection requested via web by Paula Gratiot
1. Expansion coupling upside down.
2. Need ground rod driven. Lugs on transformer are for lifting purposes for IDP, it is not a lug for a GEC although we have been allowing termination for temp poles.
ELE20-01214 Permanent Service4/6/20204/7/20204/7/2020 8:19:02 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk
ELE20-01214 Final4/6/20204/7/20204/7/2020 8:18:57 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk
ELE19-02224 Electrical Rough-In4/6/20204/7/20204/7/2020 5:10:11 AMAPASS
UFER inspection for the on-site generator. Have pictures and will send. If you have questions please call. ###-####. Thanks, Lonny Phone #: ###-#### Inspection requested via web by Lonny Baum Ok cover 3/0 copper for ufer on generator.
ELE20-01222 Final4/6/20204/7/20204/7/2020 5:09:31 AMAPASS
George Stanton Phone #: ###-#### Inspection requested via web by Danielle Henderson Ok final. Looked at job on 4/3. All labels present, 30a 2pole brkr. 200a service.
ELE20-00287 Final4/6/20204/7/20204/6/2020 1:29:36 PMACANC
Phone #: ###-#### >> Inspection requested via web by Tyler Ridley Inspection cancelled from web by: Tyler Ridley
ELE20-01214 Permanent Service4/6/20204/7/20204/6/2020 11:47:55 AMACANC
Ste #7 Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk