Inspections for the day of: Thursday, May 21, 2020.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-01724 Final5/20/20205/21/20205/21/2020 3:31:02 PMAPASS
The door will be unlocked Phone #: ###-#### Inspection requested via web by Nermin Bobaric Ok final. 15a brkr installed
ELE19-04290 Final5/20/20205/21/20205/21/2020 1:51:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok final areas listed.
ELE20-01613 Electrical Rough-In5/21/20205/21/20205/21/2020 1:09:23 PMPPASS
There will be someone home. If you have any questions please feel free to contact Jason ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Ok cover living room extension, and 2 cans lower back patio. Will probably need floor outlet to left of slider, span is over 6ft. Can look at on final.
ELE19-03017 Electrical Rough-In5/21/20205/21/20205/21/2020 12:21:26 PMPPASS
front entry rough in Phone #: ###-#### Inspection requested via web by Debby Pierce Ok cover ceiling inside main entrance on E side.
ELE20-01732 Permanent Service5/20/20205/21/20205/21/2020 11:59:27 AMPPASS
call first please- if needed I can do a video call
The issue is the conduit for the main feeder has settled ; seperated.
ID Power is doing a disconnect at 9:00.I should be done by 11:00. I am installing a slip joint- so a video call maybe all that is needed. Phone #: ###-#### Inspection requested via web by Eddy Udry Ok final. Expansion coupling installed upside down, IDP already energized. Talked to Eddy about future installs of expansion couplings.
ELE19-04725 Final5/20/20205/21/20205/21/2020 11:31:58 AMPPASS
on site contact if needed
Austin ###-#### Phone #: ###-#### Inspection requested via web by Todd Hall Ok final 4 units.
ELE19-03145 Electrical Rough-In5/21/20205/21/20205/21/2020 10:50:33 AMPPASS
Hard lid ceiling in front of elevator. Phone #: ###-#### Inspection requested via web by Kevin Burke Ok cover hardlid 1st floor N side
ELE20-01658 Temporary Service5/20/20205/21/20205/21/2020 9:45:31 AMAPASS
Phone #: ###-#### Inspection requested via web by Debby Pierce t/s u/g n ok
ELE20-00207 Final5/20/20205/21/20205/21/2020 9:23:12 AMAPASS
garage code is 5354, uninhabited. please call arron with any questions Phone #: ###-#### Inspection requested via web by aaron dill Ok final. Panel blank was needed, contacted electrician and he installed one.
ELE20-01133 Final5/20/20205/21/20205/21/2020 8:50:36 AMAPASS
8181 enter Phone #: ###-#### Inspection requested via web by Dave Brueggemann Ok final. Correction made. Wire landed in box in ceiling with blank cover.