Inspections for the day of: Friday, August 23, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01113 Final8/23/20198/23/20198/23/2019 2:22:58 PMPPART
Please call with any questions. Thanks Mark Phone #: ###-#### Inspection requested via web by Eric Brown Unablel to check upstairs. Steps were just finished and said to stay off until 8/24/19.
ELE19-01465 Rough-In Permanent Service8/22/20198/23/20198/23/2019 1:56:46 PMAPASS
David Phone #: ###-#### 2 meter pack, but only 1 service drop. p/s o/h rec ok
ELE19-03103 Final8/23/20198/23/20198/23/2019 1:34:41 PMPPASS
wes Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Ok final. Labeling present where needed.
ELE19-03152 Rough-In Permanent Service8/23/20198/23/20198/23/2019 1:34:16 PMAPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman p/s u/g n ok
ELE19-02907 Final8/23/20198/23/20198/23/2019 12:34:56 PMPPASS
Mitch- call for acess 30 min before Phone #: ###-#### Ok final. Panels labeled.
ELE19-02868 Permanent Service8/22/20198/23/20198/23/2019 12:12:23 PMAFAIL
Aaron ###-####. Talked to Aaron, he is going to meet onsite in the morning and unlock mandoor to garage. Evidently a deceased person was in house for long period of time and also owner quite a few cats. I will not go through the house. Need to verify grounding electrode system, and main water coming in/water heater bonding.
ELE19-03139 Final8/22/20198/23/20198/23/2019 11:21:32 AMPCANC
Contact Preston Seay with any questions ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Talked to Preston, wont be ready until Monday
ELE17-03287 Final8/22/20198/23/20198/23/2019 11:07:41 AMACANC
Sharrie Phone #: ###-####
ELE19-01408 Final8/22/20198/23/20198/23/2019 11:01:40 AMAPASS
Call rick for access 5-10 min prior Phone #: ###-#### Inspection requested via web by mike brown Ok final kitch, 2 bath GFI's, and utility.
ELE19-03148 Final8/21/20198/23/20198/23/2019 11:01:10 AMAPASS
Reach out to Preston Seay with any questions. ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Ok final. Labels needed are present.
ELE19-03059 Final8/21/20198/23/20198/23/2019 10:57:55 AMAPASS
Contact Preston Seay with any questions. ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Ok final. Line side connection.
ELE19-03153 Electrical Rough-In8/23/20198/23/20198/23/2019 10:57:29 AMAPASS
call for access Phone #: ###-#### Inspection requested via web by steve sellers Ok cover mstr bed, bath, closet.
ELE19-00627 Electrical Rough-In8/22/20198/23/20198/23/2019 10:44:13 AMAPASS
Pool house rough inspection Phone #: ###-#### Inspection requested via web by Dave Conrad Ok cover pool room bathroom and dressing room. In wall splice done on conductors feeding sub panel in hallway outside bath. The splice is 600v shrink tube rated for indoor and outdoor use. Conductors are connected by irreversible crimps, and individually heat shrinked, then all heat shrinked as a whole.
ELE19-02954 Conference8/22/20198/23/20198/22/2019 1:19:54 PMADONE
Check exterior Phone #: ###-#### Inspection requested via web by Josh Reeder Met with Josh on 8/22/19 to discuss service location. Existing service to be replaced with new in same location. There are 2 windows, 1 on each side of overhead mast. 230.9(A) Ex. states that conductors that are run above top of window shall be permitted to be less than 3ft. Both windows do not open in upward motion. They both open in like 2 doors. With windows open, you could reach conductors.