ELE19-01113
| Final | 8/23/2019 | 8/23/2019 | 8/23/2019 2:22:58 PM | P | PART |
|
|
Please call with any questions. Thanks Mark Phone #: ###-#### Inspection requested via web by Eric Brown Unablel to check upstairs. Steps were just finished and said to stay off until 8/24/19.
|
ELE19-01465
| Rough-In Permanent Service | 8/22/2019 | 8/23/2019 | 8/23/2019 1:56:46 PM | A | PASS |
|
|
David Phone #: ###-#### 2 meter pack, but only 1 service drop. p/s o/h rec ok
|
ELE19-03103
| Final | 8/23/2019 | 8/23/2019 | 8/23/2019 1:34:41 PM | P | PASS |
|
|
wes Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Ok final. Labeling present where needed.
|
ELE19-03152
| Rough-In Permanent Service | 8/23/2019 | 8/23/2019 | 8/23/2019 1:34:16 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman p/s u/g n ok
|
ELE19-02907
| Final | 8/23/2019 | 8/23/2019 | 8/23/2019 12:34:56 PM | P | PASS |
|
|
Mitch- call for acess 30 min before Phone #: ###-#### Ok final. Panels labeled.
|
ELE19-02868
| Permanent Service | 8/22/2019 | 8/23/2019 | 8/23/2019 12:12:23 PM | A | FAIL |
|
|
Aaron ###-####. Talked to Aaron, he is going to meet onsite in the morning and unlock mandoor to garage. Evidently a deceased person was in house for long period of time and also owner quite a few cats. I will not go through the house. Need to verify grounding electrode system, and main water coming in/water heater bonding.
|
ELE19-03139
| Final | 8/22/2019 | 8/23/2019 | 8/23/2019 11:21:32 AM | P | CANC |
|
|
Contact Preston Seay with any questions ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Talked to Preston, wont be ready until Monday
|
ELE17-03287
| Final | 8/22/2019 | 8/23/2019 | 8/23/2019 11:07:41 AM | A | CANC |
|
|
Sharrie Phone #: ###-####
|
ELE19-01408
| Final | 8/22/2019 | 8/23/2019 | 8/23/2019 11:01:40 AM | A | PASS |
|
|
Call rick for access 5-10 min prior Phone #: ###-#### Inspection requested via web by mike brown Ok final kitch, 2 bath GFI's, and utility.
|
ELE19-03148
| Final | 8/21/2019 | 8/23/2019 | 8/23/2019 11:01:10 AM | A | PASS |
|
|
Reach out to Preston Seay with any questions. ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Ok final. Labels needed are present.
|
ELE19-03059
| Final | 8/21/2019 | 8/23/2019 | 8/23/2019 10:57:55 AM | A | PASS |
|
|
Contact Preston Seay with any questions. ###-#### Phone #: ###-#### Inspection requested via web by Rob Maes Ok final. Line side connection.
|
ELE19-03153
| Electrical Rough-In | 8/23/2019 | 8/23/2019 | 8/23/2019 10:57:29 AM | A | PASS |
|
|
call for access Phone #: ###-#### Inspection requested via web by steve sellers Ok cover mstr bed, bath, closet.
|
ELE19-00627
| Electrical Rough-In | 8/22/2019 | 8/23/2019 | 8/23/2019 10:44:13 AM | A | PASS |
|
|
Pool house rough inspection Phone #: ###-#### Inspection requested via web by Dave Conrad Ok cover pool room bathroom and dressing room. In wall splice done on conductors feeding sub panel in hallway outside bath. The splice is 600v shrink tube rated for indoor and outdoor use. Conductors are connected by irreversible crimps, and individually heat shrinked, then all heat shrinked as a whole.
|
ELE19-02954
| Conference | 8/22/2019 | 8/23/2019 | 8/22/2019 1:19:54 PM | A | DONE |
|
|
Check exterior Phone #: ###-#### Inspection requested via web by Josh Reeder Met with Josh on 8/22/19 to discuss service location. Existing service to be replaced with new in same location. There are 2 windows, 1 on each side of overhead mast. 230.9(A) Ex. states that conductors that are run above top of window shall be permitted to be less than 3ft. Both windows do not open in upward motion. They both open in like 2 doors. With windows open, you could reach conductors.
|