ELE19-02362
| Rough-In Permanent Service | 9/6/2019 | 9/6/2019 | 9/6/2019 2:38:55 PM | P | PASS |
|
|
Units 108 and 109 Phone #: ###-#### Inspection requested via web by Cevyn Recla Ok cover units 108-109 p/s u/g n ok
|
ELE19-03185
| Electrical Rough-In | 9/5/2019 | 9/6/2019 | 9/6/2019 2:00:18 PM | P | PASS |
|
|
Contact is Josh Smith Phone #: ###-#### Inspection requested via web by Candy Magly Ok cover dance rm wall, and practice rm wall
|
ELE19-03345
| Permanent Service | 9/6/2019 | 9/6/2019 | 9/6/2019 1:52:00 PM | P | PASS |
|
|
For future energize service inspection, a permanent service needs to be requested. p/s o/h rec ok
|
ELE19-03345
| Final | 9/6/2019 | 9/6/2019 | 9/6/2019 1:48:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Steven Ragan Ok final new meter base install.
|
ELE19-03339
| Permanent Service | 9/6/2019 | 9/6/2019 | 9/6/2019 1:47:31 PM | P | PASS |
|
|
Mast fell off home last night. We are hoping to have it up by 11:00 so Idaho Power can reconnect. Phone #: ###-#### Inspection requested via web by Tyler Bowen p/s o/h rec ok
|
ELE19-03200
| Electrical Rough-In | 9/6/2019 | 9/6/2019 | 9/6/2019 1:17:07 PM | P | PASS |
|
|
Roughed in for solar on roof. Roughed in EMT from roof down to future surface mount inverter location. Phone #: ###-#### Inspection requested via web by Jesse Simpson Ok cover EMT for solar.
|
ELE19-03112
| Rough-In Permanent Service | 9/5/2019 | 9/6/2019 | 9/6/2019 1:16:39 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok cover. 1 hr fire barrier will be 5/8 sheetrock walls and lid to seperate spaces. 2 meters on structure. Panel on warm wall will also have 5/8. p/s u/g n ok both meters.
|
ELE19-02843
| Electrical Rough-In | 9/6/2019 | 9/6/2019 | 9/6/2019 1:07:55 PM | P | PASS |
|
|
Under tile floor heat upstairs master bathroom Phone #: ###-#### Inspection requested via web by steve sellers Ok cover flr heat up.
|
ELE19-02336
| Final | 9/4/2019 | 9/6/2019 | 9/6/2019 1:07:23 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Same Electric Ok final. Island was removed.
|
ELE19-03199
| Electrical Rough-In | 9/6/2019 | 9/6/2019 | 9/6/2019 12:41:56 PM | P | PASS |
|
|
Repair electrical outlets in house, extended bathroom circuit, and well pump circuit Phone #: ###-#### Inspection requested via web by Kendra Lanham Ok cover. Everything is to be fished in.
|
ELE19-03254
| Final | 9/5/2019 | 9/6/2019 | 9/6/2019 12:03:29 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley Ok final 1 light.
|
ELE19-01061
| Final | 9/5/2019 | 9/6/2019 | 9/6/2019 12:03:09 PM | A | PASS |
|
|
Please contact Caleb with any questions ###-####. OK to enter property. The keys are in the dryer vent by the split duct unit in the back, to the right of the back door of Unit B. Phone #: ###-#### Inspection requested via web by Caleb Gaylord Ok final.
|
ELE19-00977
| Final | 9/5/2019 | 9/6/2019 | 9/6/2019 11:44:08 AM | A | PASS |
|
|
Please call ahead 30 mins for access Phone #: ###-#### Inspection requested via web by John VanZandt Ok final.
|
ELE19-03278
| Rough-In Permanent Service | 9/5/2019 | 9/6/2019 | 9/6/2019 11:20:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nermin Bobaric Ok cover. p/s u/g n ok
|
ELE19-03285
| Electrical Rough-In | 9/4/2019 | 9/6/2019 | 9/6/2019 10:33:48 AM | A | PASS |
|
|
the homeowner will be there till 12:00, Erin ###-#### Phone #: ###-#### Inspection requested via web by Dale Johnson Ok cover basement utility.
|
ELE17-03287
| Permanent Service | 9/5/2019 | 9/6/2019 | 9/6/2019 10:31:45 AM | A | PASS |
|
|
Cooper Phone #: ###-#### There is a 1 hr fire barrier between units. Need 2nd meter. p/s u/g n ok
|
ELE15-02574
| ELE-Aging Inspection | 9/6/2019 | 9/6/2019 | 9/6/2019 9:31:59 AM | | CANC |
|
|
|
ELE19-02148
| Final | 9/5/2019 | 9/6/2019 | 9/6/2019 9:17:10 AM | A | PASS |
|
|
Inspection requested via web by ERIC CENTERS Ok final.
|
ELE19-03247
| Electrical Rough-In | 9/5/2019 | 9/6/2019 | 9/6/2019 8:43:53 AM | A | PASS |
|
|
inspecting deck covering at back of house, the general will be working there. inspecting conduits in trench. Phone #: ###-#### Inspection requested via web by Taras Shulga Ok cover back patio.
|