Inspections for the day of: Thursday, October 10, 2019.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02842 Final10/10/201910/10/201910/10/2019 2:07:09 PMPPASS
Garage is 5477 Phone #: ###-#### Inspection requested via web by Ryan Wilson...ok to final
ELE19-02736 Final10/10/201910/10/201910/10/2019 2:06:08 PMPPASS
Garage code is 5477 Phone #: ###-#### Inspection requested via web by Ryan Wilson...
corrections made..ok to final
ELE19-03706 Electrical Rough-In10/10/201910/10/201910/10/2019 1:25:28 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Jennings...rough in ok to cover...
intersystem bond needs installed-check at final..
discussed with contractor the combination of inspection types R, RP/S, P/S
ELE19-03706 Permanent Service10/10/201910/10/201910/10/2019 1:23:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Jennings...
p/s u/g new ok
ELE19-03818 Electrical Rough-In10/9/201910/10/201910/10/2019 11:06:11 AMAPASS
Underground and Bonding Inspection On Pool Phone #: ###-#### Inspection requested via web by Louis Keller...
underground and bond wire at pool equipment rm only...ok to cover
remaining underground and bonding of pool will require future inspection
ELE19-03881 Electrical Rough-In10/9/201910/10/201910/10/2019 10:17:51 AMAPASS
Underground inspection for hot tub - it is in the back yard and there is not fence - so Inspector can get in. Phone #: ###-#### Inspection requested via web by Winters LLC...
ok to cover...feed to hot tub and yard outlet feeds
ELE19-03828 Final10/9/201910/10/201910/10/2019 9:42:05 AMAFAIL
Homeowner''s will be home. Phone #: ###-#### Inspection requested via web by Dean Gernaat..
1) OCPD on new A/C shall match nameplate rating
2) furnace wiring shall be brought to code...no code violation shall be retained...OCPD rated for furnace, wiring protected from physical damage, and removed wiring shall be completely removed and disconnected
ELE19-03737 Electrical Rough-In10/9/201910/10/201910/10/2019 9:05:35 AMAPASS
Thank you! Phone #: ###-#### Inspection requested via web by BRS Permitting...UL listed equipment...platform for panel will be installed...contractor aware of
ELE19-03363 Final10/9/201910/10/201910/10/2019 8:30:28 AMAPASS
The permit packet is between the house and the disconnect. Phone #: ###-#### Inspection requested via web by Amy Simms...labelling, disconnect, and OCPD ok
ELE18-03414 Final10/10/201910/10/201910/10/2019 8:29:36 AMAPASS
job complete...ok to final