Inspections for the day of: Thursday, October 18, 2018.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-00717 ELE-Aging Inspection10/18/201810/18/201810/23/2018 12:38:30 PM FAIL
final inspection needs scheduled by contractor..contact has been made
ELE18-03996 Final10/18/201810/18/201810/18/2018 3:43:25 PMPPASS
bldg ON-1...ok to final
ELE18-03995 Final10/18/201810/18/201810/18/2018 3:42:59 PMPPASS
bldg ON...ok to final
ELE18-03990 Final10/18/201810/18/201810/18/2018 3:42:26 PMPPASS
bldg A...ok to final
ELE18-02922 Final10/17/201810/18/201810/18/2018 3:41:51 PMPPASS
final for bldg P Phone #: ###-#### Inspection requested via web by Todd Hall...ok to final
ELE13-00373 ELE-Aging Inspection10/18/201810/18/201810/18/2018 2:19:04 PM PASS
permit expired
ELE13-00373 DOC - Permit Expired10/18/201810/18/201810/18/2018 2:18:45 PMPPASS
multiple remodels have been done since permit pulled...remodels have permits by other contractors...expiring permit
ELE18-02549 Final10/18/201810/18/201810/18/2018 2:10:31 PMPPASS
Call for access Phone #: ###-#### Inspection requested via web by John VanZandt...ok to final
ELE18-02550 Final10/18/201810/18/201810/18/2018 2:10:04 PMPPASS
Call for access Phone #: ###-#### Inspection requested via web by John VanZandt...ok to final
ELE18-04006 Electrical Rough-In10/18/201810/18/201810/18/2018 1:59:33 PMPPASS
need cover for walls and ceiling owner should be there Phone #: ###-#### Inspection requested via web by dennis mcneely...ok to cover-new bedroom and bathroom off living rm
MIS18-00406 ELE-Conference10/17/201810/18/201810/18/2018 1:36:20 PMANH
working without permits Phone #: ###-####..
no one home added correction notice for electrical...contractor showed up while in my car...i motioned to him to speak with me while he was at front door and he ignored me and walked inside and closed door...would not answer door after...checked license plate and plate number references company name- AC TO Z...called mech inspector and plumbing inspector and informed them of situation
ELE18-03989 Conference10/17/201810/18/201810/18/2018 12:13:08 PMAPASS
Mark Phone #: ###-####...discussed the raising of his riser...going from a 6ft riser to 10ft riser to get clearance over new gazebo...riser replacement only...discussed wire size and am ok with ID PWR reconnecting before inspection if need be
ELE18-03990 Final10/17/201810/18/201810/18/2018 11:18:25 AMACANC
final for bldg A Phone #: ###-#### Inspection requested via web by Todd Hall...moved to next day AM
ELE18-03985 Final10/17/201810/18/201810/18/2018 11:07:25 AMAPASS
Robert Phone #: ###-####...ok to final
ELE18-03965 Rough-In Permanent Service10/17/201810/18/201810/18/2018 10:48:01 AMAPASS
Please call first
If I cannot answer. The key is under the blue recycle bin in the back of the building. Phone #: ###-#### Inspection requested via web by Eddy Udry....
verify at final labelling outside and inside panel/junction is completely sealed
p/s o/h reconnect ok
ELE18-03592 Final10/17/201810/18/201810/18/2018 10:26:09 AMANR
Please call our office when on the way so we can let the homeowner aware and call Wayne with any questions at ###-####. Phone #: ###-#### Inspection requested via web by William Salts...rescheduled for next day 10/19/18 for AM
ELE18-02295 Electrical Rough-In10/17/201810/18/201810/18/2018 10:16:04 AMAPASS
Partial rough in inspection. Phone #: ###-#### Inspection requested via web by Debby Pierce...GYM west offices walls ok to cover...discussed vestibules of GYM and bonding LV rack
ELE18-00849 Final10/17/201810/18/201810/18/2018 9:44:27 AMAPART
Please call 30 minutes ahead if possible. Bob is our site contact Phone #: ###-#### Inspection requested via web by Graham Estep..
left to inspect: circuit #8, GFI protection for vending, GFI within 6ft sink upstairs QC rm, convur, work tables fed off poles, misc equipment, panel rm-panels, LV rack bond..
temp occupency given
ELE18-02300 Electrical Rough-In10/18/201810/18/201810/18/2018 8:40:48 AMAPASS
Gym walls for cover and roof penetrations Phone #: ###-#### Inspection requested via web by Jason Parke...ok to cover designated areas...discussed 2 vestibules in GYM that need built once sheeted and sheetrock-1 E-light in ea
ELE18-03965 Permanent Service10/16/201810/18/201810/18/2018 7:42:26 AMPCANC
please call so i can get you in
###-#### Phone #: ###-#### Inspection requested via web by Eddy Udry...scheduled for AM as well