ELE18-02300
| Electrical Rough-In | 11/5/2018 | 11/5/2018 | 11/5/2018 3:01:58 PM | P | PASS |
|
|
De-energize main switch board, adding 4 breakers and terminating feeders, re-energize approximately 3:30. Will call when getting close to re-energizing Phone #: ###-#### Inspection requested via web by Jason Parke... new sub feeds to existing service ok...4 breakers added
|
ELE18-03172
| Final | 10/31/2018 | 11/5/2018 | 11/5/2018 2:27:09 PM | P | PASS |
|
|
Home owner will be home after. 2:00 Phone #: ###-#### Inspection requested via web by Terry Scott...ok to final
|
ELE18-03498
| Final | 11/5/2018 | 11/5/2018 | 11/5/2018 1:50:30 PM | P | PASS |
|
|
please contact Paul or Chris at ###-#### so we can coordinate access to the school property along w/available cut sheets for inspectors approval. Thank you Phone #: ###-#### Inspection requested via web by CHRIS CARMINE... job complete...ok to final
|
ELE18-03498
| Rough-In Permanent Service | 11/2/2018 | 11/5/2018 | 11/5/2018 1:50:04 PM | P | PASS |
|
|
please contact Paul or Chris at ###-#### so we can coordinate access to the school property along w/available cut sheets for inspectors approval. Thank you Phone #: ###-#### Inspection requested via web by CHRIS CARMINE... UL listing of fixtures verified...exterior fixtures only on building and parking lot
|
ELE18-03729
| Final | 11/4/2018 | 11/5/2018 | 11/5/2018 1:15:11 PM | P | PASS |
|
|
Please call / text for lock box code if no one is home. Phone #: ###-#### Inspection requested via web by Cortney Hopper...ok to final
|
ELE18-03173
| Final | 11/5/2018 | 11/5/2018 | 11/5/2018 12:58:21 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI... 1..hood needs breaker lock out installed-hard wired appliance 2..sub panel needs labelled correctly and legible 3..ground rods shall be minimum 6ft apart stated at time of service inspection and not addressed 4..riser at service shall be strapped withinb3ft
|
ELE18-04045
| Final | 11/2/2018 | 11/5/2018 | 11/5/2018 9:40:59 AM | A | PASS |
|
|
If the customer does not answer the front door the back door will be unlocked for you. Phone #: ###-#### Inspection requested via web by Angela Stears...ok to final
|
ELE18-04181
| Final | 11/2/2018 | 11/5/2018 | 11/5/2018 9:27:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JENNY EMEL... OCPD, disconnect and labelling...ok to final
|
ELE18-04129
| Final | 11/2/2018 | 11/5/2018 | 11/5/2018 9:26:46 AM | A | PASS |
|
|
Please contact Micah at ###-#### so that I can make sure an installer will meet you on site for the inspection. Thanks! Phone #: ###-#### Inspection requested via web by Jesse Simpson ok to final
|
ELE18-04256
| Final | 11/4/2018 | 11/5/2018 | 11/5/2018 8:55:37 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura.... final not ready at this time...need power on for final
|
ELE18-04256
| Permanent Service | 11/5/2018 | 11/5/2018 | 11/5/2018 8:54:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura... p/s u/g new ok
|