Inspections for the day of: Tuesday, December 11, 2018.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-04412 Electrical Rough-In12/11/201812/11/201812/11/2018 3:11:04 PMPPASS
call 15 mins ahead- Craig Phone #: ###-####...
rewire sub panels-garage and basement ok to cover...new dwnstairs living rm wall and dwn stairs bed rm walls ok to cover
ELE17-03573 Final12/10/201812/11/201812/11/2018 1:18:37 PMPPASS
Phone #: ###-#### Inspection requested via web by michael hunt...corrections made...ok to final
ELE18-02300 Electrical Rough-In12/11/201812/11/201812/11/2018 12:55:09 PMPPASS
Hallways ceiling cover Phone #: ###-#### Inspection requested via web by Jason Parke..

hall grid ok
LV tray bonding verified as well
ELE18-04417 Electrical Rough-In12/11/201812/11/201812/11/2018 12:17:36 PMPPASS
Jordan Hill. Phone #: ###-#### Inspection requested via web by Ashley Lanham...
UL listings verified
40A breaker in panel
access side of house for final
ELE18-04638 Final12/11/201812/11/201812/11/2018 11:34:02 AMPPASS
Please call our office number ###-#### when on the way so we can let the customer know. Phone #: ###-#### Inspection requested via web by William Salts...
ok to final
ELE18-04371 Final12/11/201812/11/201812/11/2018 11:07:04 AMPPASS
Phone #: ###-#### Inspection requested via web by Barbara Szurgot...corrections made...ok to final
ELE18-03245 Final12/11/201812/11/201812/11/2018 10:54:36 AMAPASS
final for remodel...corrections made...ok to final
ELE18-04685 Rough-In Permanent Service12/11/201812/11/201812/11/2018 10:47:43 AMPPASS
Trench Inspection... Any questions, call Tom ###-#### Phone #: ###-#### Inspection requested via web by Bonnie Page...

p/s u/g 2 sprinkler timers ok to connect
ELE18-04685 Electrical Rough-In12/11/201812/11/201812/11/2018 10:46:36 AMPPASS
Trench Inspection... Any questions, call Tom ###-#### Inspection requested via web by Bonnie Page...
ok to cover
ELE18-04417 Electrical Rough-In12/10/201812/11/201812/11/2018 10:09:21 AMACANC
Jordan Hill. Phone #: ###-#### Inspection requested via web by Ashley Lanham...rescheduled to PM as per GC
ELE18-04629 Electrical Rough-In12/10/201812/11/201812/11/2018 10:07:04 AMAPASS
Taylor Barton "
###-####" Phone #: ###-#### Inspection requested via web by BRS Permitting...

UL listings verified
breaker in panel or lineside tap depending on homeowner request..panel full with non used 50A breaker...verify fused or nonfused disconnect at final
ELE18-04581 Final12/10/201812/11/201812/11/2018 8:59:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Winters LLC...
ok to final
ELE18-04674 Rough-In Permanent Service12/10/201812/11/201812/11/2018 8:40:06 AMAPASS
Please call when done Phone #: ###-#### Inspection requested via web by Thomas wilson

p/s u/g new ok
ELE18-04639 Rough-In Permanent Service12/10/201812/11/201812/11/2018 6:34:54 AMACANC
>> Inspection requested via web by Dylan Pierce Inspection cancelled from web by: Dylan Pierce
ELE18-04562 Final12/7/201812/11/201812/10/2018 1:03:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Rob Maes...
OCPD, disconnect, and labelling ok