Inspections for the day of: Thursday, April 18, 2019.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00149 Final4/18/20194/18/20194/18/2019 2:13:35 PMPPASS
Phone #: ###-#### Inspection requested via web by kendall bender...ok to final
ELE19-01380 Final4/18/20194/18/20194/18/2019 1:39:11 PMPPASS
Corbin Metcalf ###-####
Gate on the right side
Phone #: ###-#### Inspection requested via web by Samatha Solberg...
corrections made...ok to final
ELE19-01402 Rough-In Permanent Service4/18/20194/18/20194/18/2019 1:08:34 PMPPASS
Phone #: ###-#### Inspection requested via web by Don Conley...
rough ok to cover
p/s u/g new ok
ELE18-04742 Final4/18/20194/18/20194/18/2019 12:32:25 PMPFAIL
Please contact Tracy ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Todd Hall...
1) intersystem bond needs installed at service
2) kitchen island needs finished..access to verify outlets, D/W, and microwave
3) master bath GFCI has broken plate
4) all areas with outlets and switches in tile need to be completed
ELE18-04715 Final4/17/20194/18/20194/18/2019 11:47:14 AMAPART
Ron Phone #: ###-####...
2nd floor ok...discussed addressing 1st floor grid...wiring high voltage and low voltage laying on grid
ELE19-01379 Permanent Service4/18/20194/18/20194/18/2019 11:06:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Kotton Corder...
p/s u/g new location ok
ELE18-03476 Rough-In Permanent Service4/17/20194/18/20194/18/2019 10:51:38 AMAPASS
Zack Phone #: ###-####...
area 1 ceilings and area 3 bath hardlids
ELE19-01396 Electrical Rough-In4/17/20194/18/20194/18/2019 10:05:09 AMAPASS
Kitchen only Phone #: ###-#### Inspection requested via web by David Green...
rough in ok to cover
ELE19-00191 Electrical Rough-In4/17/20194/18/20194/18/2019 9:45:40 AMANR
Drew Phone #: ###-####...
changed/scheduled conference
ELE19-00191 Conference4/18/20194/18/20194/18/2019 9:45:15 AMAPASS
Drew Phone #: ###-####...
discussed make up, stapling, and areas needing nailplates
ELE18-03388 Final4/17/20194/18/20194/18/2019 9:16:22 AMAPASS
Ready for electrical final. homeowner is Paul at ###-####. Said anytime would be good. Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer...
ok to final
ELE19-01158 Final4/18/20194/18/20194/18/2019 8:55:59 AMAPASS
Service has been terminated by Idaho Power, ready for final inspection. Gate will be open too access back yard shop, where new service is. Phone #: ###-#### Inspection requested via web by Kurt Carlson...
work on this permit complete
trench from new panel has no pipe or circuit installed at time of inspection...trench is empty
ok to final
ELE19-00770 Electrical Rough-In4/17/20194/18/20194/18/2019 8:32:10 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton....
ok to cover back existing wall, new wall and back offices x 2
ELE19-00538 Final4/17/20194/18/20194/18/2019 7:58:15 AMAPASS
Please call Lynn at ###-#### prior to arrival. Thank you! Phone #: ###-#### Inspection requested via web by Lynn Proctor...
work complete...ok to final
ELE19-01169 Final4/15/20194/18/20194/16/2019 8:28:58 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Rob Maes Inspection cancelled from web by: Rob Maes