ELE19-01124
| Electrical Rough-In | 6/24/2019 | 6/24/2019 | 6/24/2019 4:04:35 PM | P | PASS |
|
|
Electrical rough in for accessory structure. Please call with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore... rough ok to cover minus laundry area circuit needs fixed and one added discussed location of mini split disconnect
|
ELE19-01124
| Rough-In Permanent Service | 6/24/2019 | 6/24/2019 | 6/24/2019 4:00:06 PM | P | NR |
|
|
Electrical rough in for accessory structure. Please call with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore... service not ready at this time...discussed what needed done for next inspection
|
ELE19-02210
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 2:31:14 PM | P | PASS |
|
|
Aaron Phone #: ###-####.... battery backup added to solar ok new panel replacing existing-same size exterior disconnect added using existing riser and meter base power on at time of final and all working ok to final
|
ELE16-03205
| ELE-Aging Inspection | 6/24/2019 | 6/24/2019 | 6/24/2019 1:44:09 PM | | DONE |
|
|
still needs completed
|
ELE18-01191
| Final | 6/24/2019 | 6/24/2019 | 6/24/2019 1:39:51 PM | P | FAIL |
|
|
contractor needs to get access and schedule final...previous final failed and contractor making no effort to rectify
|
ELE15-03810
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 1:32:49 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Louis Keller...ok to final
|
ELE19-01031
| Final | 6/24/2019 | 6/24/2019 | 6/24/2019 12:53:18 PM | P | FAIL |
|
|
Jason is contact person. Gate code 7011 Phone #: ###-#### Inspection requested via web by Sherry Allen... 1) Available Fault Current label at service needs done 2) meter needs installed before final can be given
|
ELE19-02339
| Permanent Service | 6/24/2019 | 6/24/2019 | 6/24/2019 12:21:51 PM | P | FAIL |
|
|
turn on permanent service // Randy Phone #: ###-####... 1) Available Fault Current label needs applied to meter pack 2) breakers at meter pack need permanent and weather resistant labelling
|
ELE19-01212
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 12:08:41 PM | A | NR |
|
|
We are looking for a temp occupancy final, please contact Mike Hastings ###-####. Thank you, Sean Phone #: ###-#### Inspection requested via web by Kevin Perez... exposed wires at multiple locations...unable to ok...rescheduled for next day AM...contractor will notify when ready
|
ELE19-02310
| Electrical Rough-In | 6/21/2019 | 6/24/2019 | 6/24/2019 11:23:51 AM | A | NH |
|
|
Call Kaleb for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg... no access...contact given has been notified
|
ELE19-00651
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 11:11:59 AM | A | FAIL |
|
|
garage code 0555 Phone #: ###-#### Inspection requested via web by Jay Hutchison... 1) furnace needs disconnect...not within sight of OCPD 2)outlet in garage cabinet needs properly attached to box with proper arc protection..box resessed 3) east outlet in garage needs proper attachment to bos...tightened 4) ironing board outlet shows open ground 5) oven breaker does not match nameplate rating 6) can in master bedroom not operational 7) no access to master bath and closet at time of inspection 8) all bedroom circuits shall have AFCI protection 9) all openings in bedrooms shall have AFCI protection-switches for back patio lights
|
ELE19-02300
| Rough-In Permanent Service | 6/21/2019 | 6/24/2019 | 6/24/2019 10:05:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Heideman... rough ok to cover..p/s u/g new ok
|
ELE19-02213
| Electrical Rough-In | 6/23/2019 | 6/24/2019 | 6/24/2019 9:38:18 AM | A | PASS |
|
|
2nd 6 units Phone #: ###-#### Inspection requested via web by Kevin Burke.... units 105,106,205,206,305,306...ok to cover
|
ELE19-01997
| Final | 6/20/2019 | 6/24/2019 | 6/24/2019 9:03:55 AM | A | PASS |
|
|
Inspection requested via web by BRS Permitting ...Labelling, disconnect and OCPD ok to final
|
ELE18-04053
| Electrical Rough-In | 6/21/2019 | 6/24/2019 | 6/24/2019 8:39:15 AM | A | PASS |
|
|
Contact: Mike Mulvahill Phone #: ###-#### Inspection requested via web by Deb Gooden... electrical rm and fire riser rm ok
|
ELE19-02125
| Final | 6/20/2019 | 6/24/2019 | 6/24/2019 7:12:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rob Maes...was finaled on 6/21/19
|