Inspections for the day of: Monday, June 24, 2019.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01124 Electrical Rough-In6/24/20196/24/20196/24/2019 4:04:35 PMPPASS
Electrical rough in for accessory structure. Please call with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore...
rough ok to cover minus laundry area
circuit needs fixed and one added
discussed location of mini split disconnect
ELE19-01124 Rough-In Permanent Service6/24/20196/24/20196/24/2019 4:00:06 PMPNR
Electrical rough in for accessory structure. Please call with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore...
service not ready at this time...discussed what needed done for next inspection
ELE19-02210 Final6/21/20196/24/20196/24/2019 2:31:14 PMPPASS
Aaron Phone #: ###-####....
battery backup added to solar ok
new panel replacing existing-same size
exterior disconnect added
using existing riser and meter base
power on at time of final and all working
ok to final
ELE16-03205 ELE-Aging Inspection6/24/20196/24/20196/24/2019 1:44:09 PM DONE
still needs completed
ELE18-01191 Final6/24/20196/24/20196/24/2019 1:39:51 PMPFAIL
contractor needs to get access and schedule final...previous final failed and contractor making no effort to rectify
ELE15-03810 Final6/21/20196/24/20196/24/2019 1:32:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Louis Keller...ok to final
ELE19-01031 Final6/24/20196/24/20196/24/2019 12:53:18 PMPFAIL
Jason is contact person. Gate code 7011
Phone #: ###-#### Inspection requested via web by Sherry Allen...
1) Available Fault Current label at service needs done
2) meter needs installed before final can be given
ELE19-02339 Permanent Service6/24/20196/24/20196/24/2019 12:21:51 PMPFAIL
turn on permanent service // Randy Phone #: ###-####...
1) Available Fault Current label needs applied to meter pack
2) breakers at meter pack need permanent and weather resistant labelling
ELE19-01212 Final6/21/20196/24/20196/24/2019 12:08:41 PMANR
We are looking for a temp occupancy final, please contact Mike Hastings ###-####. Thank you,
Sean Phone #: ###-#### Inspection requested via web by Kevin Perez...
exposed wires at multiple locations...unable to ok...rescheduled for next day AM...contractor will notify when ready
ELE19-02310 Electrical Rough-In6/21/20196/24/20196/24/2019 11:23:51 AMANH
Call Kaleb for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg...
no access...contact given has been notified
ELE19-00651 Final6/21/20196/24/20196/24/2019 11:11:59 AMAFAIL
garage code 0555 Phone #: ###-#### Inspection requested via web by Jay Hutchison...
1) furnace needs disconnect...not within sight of OCPD
2)outlet in garage cabinet needs properly attached to box with proper arc protection..box resessed
3) east outlet in garage needs proper attachment to bos...tightened
4) ironing board outlet shows open ground
5) oven breaker does not match nameplate rating
6) can in master bedroom not operational
7) no access to master bath and closet at time of inspection
8) all bedroom circuits shall have AFCI protection
9) all openings in bedrooms shall have AFCI protection-switches for back patio lights
ELE19-02300 Rough-In Permanent Service6/21/20196/24/20196/24/2019 10:05:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Kevin Heideman...
rough ok to cover..p/s u/g new ok
ELE19-02213 Electrical Rough-In6/23/20196/24/20196/24/2019 9:38:18 AMAPASS
2nd 6 units Phone #: ###-#### Inspection requested via web by Kevin Burke....
units 105,106,205,206,305,306...ok to cover
ELE19-01997 Final6/20/20196/24/20196/24/2019 9:03:55 AMAPASS
Inspection requested via web by BRS Permitting
...Labelling, disconnect and OCPD ok to final
ELE18-04053 Electrical Rough-In6/21/20196/24/20196/24/2019 8:39:15 AMAPASS
Contact: Mike Mulvahill Phone #: ###-#### Inspection requested via web by Deb Gooden...
electrical rm and fire riser rm ok
ELE19-02125 Final6/20/20196/24/20196/24/2019 7:12:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Maes...was finaled on 6/21/19