ELE17-02380
| ELE-Aging Inspection | 7/10/2019 | 7/10/2019 | 7/10/2019 3:49:19 PM | | PASS |
|
|
DOC expired
|
ELE17-02380
| DOC - Permit Expired | 7/10/2019 | 7/10/2019 | 7/10/2019 3:49:03 PM | P | PASS |
|
|
permit expired...no activity in 180 days
|
ELE19-02534
| Conference | 7/9/2019 | 7/10/2019 | 7/10/2019 3:45:39 PM | P | PASS |
|
|
Tom, I spoke to you this morning about my unfinished basement. Since I work during the day, can you text me with the latest time you can meet on Wednesday and I can meet you at my house. Phone #: ###-#### Inspection requested via web by Daniel Grover... discussed wiring of new basement pamphlet given...homeowner competent
|
ELE18-03476
| Final | 7/9/2019 | 7/10/2019 | 7/10/2019 2:08:18 PM | P | NR |
|
|
Zack- inspection for admond area Phone #: ###-####... areas checked off in rough inspection...see notes
|
ELE18-03476
| Electrical Rough-In | 7/10/2019 | 7/10/2019 | 7/10/2019 2:07:10 PM | P | PASS |
|
|
Zack- inspection for admond area Phone #: ###-####...areas approved as finaled...Admin up to line 16 ok to occupy
|
ELE18-04786
| Final | 7/10/2019 | 7/10/2019 | 7/10/2019 1:32:36 PM | P | FAIL |
|
|
Garage code 8671 Phone #: ###-#### Inspection requested via web by Kotton Corder... 1) all walls 2ft or larger shall have an outlet 2) all romex under 8ft ran horizontally shall be protected from physical damage 3) outlet shall be installed within 3ft of bath sink 4) a seperate circuit needs ran to ea disposal.. no load shall not exceed 80 percent of circuit
|
ELE19-02542
| Electrical Rough-In | 7/10/2019 | 7/10/2019 | 7/10/2019 12:07:36 PM | P | PASS |
|
|
UFER ground inspection Phone #: ###-#### Inspection requested via web by Dan Cox.. bare copper uffer ground ok to cover
|
ELE18-04652
| Final | 7/9/2019 | 7/10/2019 | 7/10/2019 11:19:25 AM | A | PASS |
|
|
Final inspection request. Homeowner will be on site all morning. Phone #: ###-#### Inspection requested via web by Tyler Stewart... work complete...ok to final
|
ELE19-02522
| Final | 7/9/2019 | 7/10/2019 | 7/10/2019 10:36:23 AM | A | PASS |
|
|
Please call Juan with any questions Phone #: ###-#### Inspection requested via web by William Salts...existing circuits used or modified/fused ...ok to final
|
ELE19-02526
| Electrical Rough-In | 7/9/2019 | 7/10/2019 | 7/10/2019 10:00:13 AM | A | PASS |
|
|
Nick Phone #: ###-####... UL listed equipment verified...solar kit engineered and guaranteed...purchased from GoGreenSolar company discussed future inspections breaker in panel will need access for final
|
ELE19-02526
| Conference | 7/9/2019 | 7/10/2019 | 7/10/2019 9:53:51 AM | A | PASS |
|
|
Nick Phone #: ###-####... solar install requirements...homeowner competent in work
|
ELE19-02499
| Conference | 7/8/2019 | 7/10/2019 | 7/10/2019 9:05:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by GABE BEAL... discussed wiring of sun room and required outlets...work had been started...outlets will be removed off dining room circuit and use living room circuit...not requiring outlet be added on wall where existing rock is instsalled...pamphlet given
|
ELE19-01824
| Final | 7/9/2019 | 7/10/2019 | 7/10/2019 8:25:04 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt... 1) OCPD on A/C not matching nameplate or manufacturers requirement 2) A/C needs hooked up...wiring needs completed
|
ELE19-02524
| Final | 7/9/2019 | 7/10/2019 | 7/9/2019 2:00:55 PM | A | CANC |
|
|
Kelly Phone #: ###-####... did perm service inspection previous day...not ready for final
|