Inspections for the day of: Wednesday, August 15, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02951 Conference8/14/20188/15/20188/15/2018 3:17:37 PMPPASS
Call half hour before to meet // Albert Phone #: ###-####... home owner licensed electrician..discussed requirements for new bedroom addition..also service upgrade-requiring move meter to meet 3ft clearance from gas meter..discussed multiple options for new circuits and service upgrade
ELE18-02423 Electrical Rough-In8/15/20188/15/20188/15/2018 2:13:02 PMPPART
ceiling rough-in above grid. Dustin is the site foreman Phone #: ###-#### Inspection requested via web by Kerri Hamilton...entry "cloud" cover only
ELE18-02563 Electrical Rough-In8/15/20188/15/20188/15/2018 1:16:39 PMPPASS
fireplace install...ok to cover...rough complete
ELE18-03118 Temporary Service8/15/20188/15/20188/15/2018 1:05:18 PMPPASS
Phone #: ###-#### Inspection requested via web by ron spen cer...

t/s u/g n ok
ELE18-03030 Rough-In Permanent Service8/15/20188/15/20188/15/2018 12:37:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Barbara Szurgot....
corrections made...verify junction box in ceiling for sub feeds at final as well as panel inside is made into a sub panel...heated tile floor will need seperate rough in inspection...
p/s u/g ok to connect...being relocated
ELE18-00346 Final8/15/20188/15/20188/15/2018 11:37:00 AMPPASS
Call prior to going Phone #: 2083425188 >> Inspection requested via mobile web by Chris Hopkins ...job complete...ok to final
ELE18-00346 Electrical Rough-In8/14/20188/15/20188/15/2018 11:36:38 AMAPASS
Call prior to going Phone #: 2083425188 >> Inspection requested via mobile web by Chris Hopkins ..UL listings and disconnects verified
ELE18-02022 Final8/14/20188/15/20188/15/2018 11:35:30 AMAPASS
call 15 mins heads up- Richard Phone #: ###-####...met with contractor and discussed scope of work and what needed to be inspected...proper straping of conduit, LV wires off grid, and all junction boxes accessible...job complete ok to final
ELE18-02043 Conference8/14/20188/15/20188/15/2018 10:20:16 AMAPASS
Spoke with Tom and confirmed process to set up conference inspection before beginning work to upgrade from 100 amp panel to 200 amp panel. Phone #: ###-#### Inspection requested via web by Jason Anderson...went over requirements for service change...uffer ground be updated with multi branch circuits need updated 1-2 pole 20 and 1-2 pole 15...pamphlet given...owener competent
ELE18-03105 Final8/15/20188/15/20188/15/2018 9:21:24 AMAPASS
Wire new attic fan. Please FINAL Phone #: ###-#### Inspection requested via web by Stuart Welton...complete..ok to final
ELE18-03105 Electrical Rough-In8/14/20188/15/20188/15/2018 9:20:52 AMAPASS
Wire new attic fan. Please FINAL Phone #: ###-#### Inspection requested via web by Stuart Welton...used existing circuit of old ventalation fan with switch...12/2 romex in attic...ok
ELE18-02477 Final8/14/20188/15/20188/15/2018 9:18:52 AMAPASS
Yolanda Phone #: ###-####...ok to final