Inspections for the day of: Tuesday, August 20, 2019.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02879 ELE-Aging Inspection8/20/20198/20/20198/20/2019 3:41:41 PM FAIL
contractor needs to schedule final or update on progress of job
ELE19-03115 Permanent Service8/20/20198/20/20198/20/2019 3:40:02 PMPNR
Street Lighting Pedestal Phone #: ###-#### Inspection requested via web by Kevin Burke...
missing parts...rescheduled to next day
ELE19-03104 Electrical Rough-In8/19/20198/20/20198/20/2019 3:26:19 PMPPASS
Please call Luke before arrival. Phone #: ###-#### Inspection requested via web by Kevin Perez....
ok to cover...new kitchen layout and mst bath layout...existing circuits used
excluding cover for fireplaces x 2...need rough inspection once installed
ELE19-02372 Final8/19/20198/20/20198/20/2019 1:51:49 PMPPASS
verify breaker labelling and fuse size for charging stations...Rob ###-####....
fuses reduced to MOP nameplate and breakers labelled...ok to final
ELE19-00030 Electrical Rough-In8/20/20198/20/20198/20/2019 1:17:49 PMPPASS
Rough-in inspection for the southeast corner of showroom and mezzanine.
Wade Luthy, lead journeyman on-site, ###-#### Phone #: ###-#### Inspection requested via web by Bryan Atkins....
front floor deck showrm SE corner furniture pwr
mezzanine breakroom/kitchen area and room walls and hardlid...ok to cover
ELE17-02916 ELE-Aging Inspection8/20/20198/20/20198/20/2019 1:00:59 PM FAIL
contractor making no attempt scheduling required inspections
ELE19-02542 Electrical Rough-In8/20/20198/20/20198/20/2019 12:47:24 PMPPASS
Underground conduits for parking lot. Phone #: ###-#### Inspection requested via web by Dan Cox....ok to cover
ELE19-03099 Electrical Rough-In8/19/20198/20/20198/20/2019 12:22:38 PMPPASS
Access around back. I should be there. No dogs. Phone #: ###-#### Inspection requested via web by Craig Korell...
rough ok to cover
ELE19-03118 Final8/20/20198/20/20198/20/2019 11:33:30 AMPPASS
not sure what type of inspection is needed here. Intermountain Gas, fixed network install. Mike Pugh is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce...no fututre inspection needed...unmetered and no access do to height of disconnect on pole
ELE19-03118 Permanent Service8/20/20198/20/20198/20/2019 11:32:18 AMPPASS
not sure what type of inspection is needed here. Intermountain Gas, fixed network install. Mike Pugh is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce....
unmetered service with disconnect....disconnect located 20ft up on pole...#6 solid ground to ground rod...rigid conduit with weather head...unable to verify anything else without access up pole
p/s new ok
ELE18-01889 Electrical Rough-In8/20/20198/20/20198/20/2019 10:55:26 AMAPASS
roof top units....
6 units...4 units ok
2 units...panel H1A breaker space 246 and 135 need downsized to 70A....check at future inspection
ELE18-02523 Electrical Rough-In8/19/20198/20/20198/20/2019 10:50:09 AMAPASS
roof Phone #: ###-#### Inspection requested via web by Debby Pierce....
3 mini split units need fuses down sized to 20A...check future inspection
ELE19-02993 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:21:18 AMAPASS
This request is also for the house meter for the whole building for outside lights and outside outlets. Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough in ok to cover
house service will be removed off building and done by other means so only one service drop per building
p/s u/g new ok
ELE19-02992 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:18:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough in ok to cover
p/s u/g new ok
ELE19-02991 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:18:17 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough in ok to cover
p/s u/g new ok
ELE19-02990 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:17:43 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough in ok to cover
p/s u/g new ok
ELE19-02989 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:17:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough ok to cover
p/s u/g new ok
ELE19-02988 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:16:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough ok to cover
p/s u/g new ok
ELE19-02986 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:15:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough ok to cover
p/s u/g new ok
ELE19-01316 Permanent Service8/19/20198/20/20198/20/2019 10:08:32 AMPCANC
Permanent service for streets light pedestal. Phone #: ###-#### Inspection requested via web by Kevin Burke....needed to pull new permit for work...contractor notified
ELE19-01316 Final8/19/20198/20/20198/20/2019 10:05:02 AMAPASS
exterior final...complete final for building ok
ELE19-03073 Final8/16/20198/20/20198/19/2019 10:51:54 PMACANC
Please contact Barry Spencer with any questions or timeline. ###-#### Phone #: ###-#### >> Inspection requested via web by Rob Maes Inspection cancelled from web by: Rob Maes