Inspections for the day of: Tuesday, January 21, 2020.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM20-00245 Water and/or Sewer1/20/20201/21/20201/21/2020 4:30:36 PMPPASS
Phone #: ###-#### Inspection requested via web by john brown
PLM20-00245 DOC - Permit Finaled1/21/20201/21/20201/21/2020 4:30:04 PMPPASS
PLM20-00037 Plumbing Rough-in1/20/20201/21/20201/21/2020 4:07:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Steven Troxel water repipe
PLM19-05298 Groundwork1/20/20201/21/20201/21/2020 3:54:37 PMPPART
Area C (NE corner) sanitary and storm drain Phone #: ###-#### Inspection requested via web by Preston Langdon. ok to cover
PLM19-04795 Final1/21/20201/21/20201/21/2020 3:44:59 PMPPASS
Zach Phone #: ###-####
PLM20-00189 Water and/or Sewer1/21/20201/21/20201/21/2020 3:25:36 PMPCANC
Tech Henry will be on site Phone #: ###-#### Inspection requested via web by Andrea Grigsby
ok to cover
PLM20-00189 DOC - Permit Finaled1/21/20201/21/20201/21/2020 3:25:17 PMPPASS
burst. tested ok to cover
PLM19-03122 Plumbing Rough-in1/21/20201/21/20201/21/2020 3:12:10 PMPPART
Phone #: ###-#### Inspection requested via web by Julie Danible. water in walls center baths ok
PLM20-00175 Final1/16/20201/21/20201/21/2020 2:52:39 PMPNH
Craig ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
PLM20-00257 Water and/or Sewer1/21/20201/21/20201/21/2020 2:44:30 PMPPART
Phone #: ###-#### Inspection requested via web by Tom Maxwell. water and sewer ok
PLM20-00173 Final1/16/20201/21/20201/21/2020 2:11:14 PMPNR
Thanks Daryl. Lock box is by A/C code is 2100 key is to the front door.
Phone #: ###-#### Inspection requested via web by Jeffrey Hankins
PLM20-00088 Plumbing Rough-in1/21/20201/21/20201/21/2020 2:03:02 PMPPASS
Late as possible, please. Phone #: ###-#### Inspection requested via web by Troy Pherigo
PLM19-01784 Other1/17/20201/21/20201/21/2020 1:38:46 PMAPEND
Conferance
PLM19-02248 Plumbing Rough-in1/17/20201/21/20201/21/2020 12:39:30 PMAPART
MARC IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. gym r-in dwv/water and roof drains
PLM19-04679 Final1/21/20201/21/20201/21/2020 12:21:21 PMAPASS
1977 garage code Phone #: ###-#### Inspection requested via web by Jason Gale
PLM20-00222 Water and/or Sewer1/17/20201/21/20201/21/2020 12:14:06 PMAPART
Phone #: ###-#### Inspection requested via web by Jennifer Alcala. water svc and 3" drain ground work
PLM20-00022 Water Heater Final1/20/20201/21/20201/21/2020 12:00:21 PMAFAIL
Phone #: ###-#### Inspection requested via web by Scott Wickstrom. Cannot use a non-shielded band in the house.
PLM20-00247 Water and/or Sewer1/21/20201/21/20201/21/2020 11:44:26 AMAPASS
Joel Phone #: ###-#### Inspection requested via web by Nick Kuklish
PLM20-00158 Water Heater Final1/15/20201/21/20201/21/2020 11:09:48 AMAPASS
Call Chuck in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
PLM20-00243 Plumbing Rough-in1/20/20201/21/20201/21/2020 10:58:23 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Madrigal
PLM20-00233 Water Heater Final1/20/20201/21/20201/21/2020 10:36:36 AMAFAIL
James will be available Phone #: ###-#### Inspection requested via web by Andrea Grigsby
1. Pipe the T&P outside or to an approved drain.
2. The double check needs certified.
3. The expansion tank on the water svc is defective.
PLM19-03891 Groundwork1/20/20201/21/20201/21/2020 10:20:01 AMAPART
Please call Judah at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
north end eye wash and floor drain
PLM19-03183 Plumbing Rough-in1/20/20201/21/20201/21/2020 10:05:55 AMAPART
Please call prior to arrival. Phone #: ###-#### Inspection requested via web by RM Mechanical. 2 ds rr rins and mech wall north
PLM19-05148 Final1/18/20201/21/20201/21/2020 9:40:17 AMAFAIL
Contract will be on site Phone #: ###-#### Inspection requested via web by Jerry Downer
The dishwasher drain shall be loop to the high point of the cabinet
PLM20-00244 Plumbing Rough-in1/20/20201/21/20201/21/2020 9:24:07 AMAPASS
Inspection requested via web by David Stephenson
PLM20-00176 Plumbing Rough-in1/18/20201/21/20201/21/2020 9:14:02 AMAPASS
Phone #: ###-#### Inspection requested via web by David Stephenson
PLM19-04831 Final1/18/20201/21/20201/21/2020 9:13:45 AMAPASS
Garage code is 1957. Phone #: ###-#### Inspection requested via web by David Stephenson
PLM19-04796 Groundwork1/18/20201/21/20201/21/2020 8:53:18 AMAPART
Sand/Oil Interceptor Phone #: ###-#### Inspection requested via web by Preston Langdon. start 24hr test