Inspections for the day of: Friday, October 4, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM19-04218 Final10/3/201910/4/201910/4/2019 4:06:12 PMANR
Contact will be Eric Sonner. Please contact him before inspection Phone #: ###-#### Inspection requested via web by JT Waters
PLM19-04249 Water and/or Sewer10/4/201910/4/201910/4/2019 2:35:41 PMPPASS
Please call number provided before you go over for inspection. Number is for Rob, licensed plumber on the job Phone #: ###-#### Inspection requested via web by McKenna Haycock
PLM19-04249 DOC - Permit Finaled10/4/201910/4/201910/4/2019 2:35:33 PMPPASS
PLM18-05271 Plumbing Rough-in10/4/201910/4/201910/4/2019 2:07:56 PMPNH
Contact: Robert Church ###-#### Phone #: ###-#### Inspection requested via web by Brent Lacy
no answer and no details left on the notes as to what I'm supposed to be inspecting. could not find anyone on the job. reschedule
PLM19-04241 Final10/4/201910/4/201910/4/2019 1:50:58 PMPPASS
Phone #: ###-#### Inspection requested via web by Matt Jones
PLM19-04199 Final10/3/201910/4/201910/4/2019 1:21:04 PMPPASS
Have corrected - The PVB must be 12" above the highest outlet.
Raise or change to an RP Phone #: ###-#### Inspection requested via web by Lana Howard
PLM19-02387 Plumbing Rough-in10/3/201910/4/201910/4/2019 12:55:24 PMAFAIL
Call ahead to meet // Randy Phone #: ###-####
use shielded bands or remove cast and replace with abs glue joints
PLM19-03656 Groundwork10/4/201910/4/201910/4/2019 12:34:04 PMAPART
Good morning. If is possible for late morning.
Thanks Phone #: ###-#### Inspection requested via web by julio sagrero
grease drain stub-in and mechanical room ok to cover
PLM19-04205 Final10/2/201910/4/201910/4/2019 12:18:37 PMAFAIL
Please call Linda 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby
solder the mip adapter on the t&p drain line
PLM19-04227 Water and/or Sewer10/3/201910/4/201910/4/2019 12:01:05 PMAPART
Phone #: ###-#### Inspection requested via web by Scott Wickstrom
certify backflow. ok to cover
PLM19-02382 Final10/3/201910/4/201910/4/2019 11:23:31 AMAFAIL
Phone #: ###-#### Inspection requested via web by Eric Roberts
cannot use flex p-trap and the trap outlet must be level with the drain. no s trap
PLM19-00032 Final10/4/201910/4/201910/4/2019 11:07:32 AMAFAIL
1. wh flex min 18" to pex
2. ks trap arm defective
PLM19-00031 Final10/4/201910/4/201910/4/2019 11:05:12 AMACANC
284
PLM19-00027 Final10/3/201910/4/201910/4/2019 10:49:00 AMAPART
143 ok
PLM19-00024 Final10/3/201910/4/201910/4/2019 10:47:31 AMAFAIL
117 one slip joint on outlet
PLM19-00028 Final10/3/201910/4/201910/4/2019 10:46:17 AMAPART
156, 250, 355 ok
PLM19-00030 Final10/3/201910/4/201910/4/2019 10:44:45 AMAFAIL
one slip joint allowed on outlet of trap. both units
PLM19-00032 Final10/3/201910/4/201910/4/2019 10:42:59 AMAFAIL
One slip-joint on the outlet of the trap allowed.
PLM19-00031 Final10/3/201910/4/201910/4/2019 10:41:55 AMAFAIL
The water heater electrical isn't connected
PLM19-04025 Plumbing Rough-in10/3/201910/4/201910/4/2019 9:31:02 AMPPASS
Phone #: ###-#### Inspection requested via web by Jason Gonzalez