Inspections for the day of: Wednesday, December 18, 2019.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM19-04171 Groundwork12/18/201912/18/201912/18/2019 2:55:45 PMPPART
Underground rain drains. if questions call Glen @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann. pipng up to the 8" underground roof drains ok to cover. 8" is leaking at bands on the reducing wye and will be replaced
PLM19-05384 Other12/17/201912/18/201912/18/2019 10:38:02 AMAPART
Please call Jake Prior to arriving so he can be found onsite. ###-####


this is a conference inspection Phone #: ###-#### Inspection requested via web by Nicholas Paige
1. Page P2.1B shows 2" vents running horizontal more than 40 feet. Change to 2-1/2 or 3".
2. The existing drinking fountain was plumbed without a vent. Repipe to include a vent.
3. The men's rr urinals are wet vented on-top of the woman's wc's. Change carriers to 3' or re-pipe off the carriers.
PLM19-05357 Water Heater Final12/16/201912/18/201912/18/2019 9:54:43 AMAPASS
Re-inspection. Hasib will be on site 8am to put gas under test, correct "B" vent issues. Will be ready by 9 ish. Phone #: ###-#### Inspection requested via web by Scott Sparrell
PLM19-04879 Groundwork12/17/201912/18/201912/18/2019 9:27:42 AMAPASS
Meet on site Phone #: ###-#### Inspection requested via web by Ben Davis
PLM19-00625 Final12/17/201912/18/201912/18/2019 9:07:32 AMAPASS
homeowner should be home, if no answer push up garage door on left. Phone #: ###-#### Inspection requested via web by Tobi Wilson
PLM19-05391 Groundwork12/17/201912/18/201912/18/2019 8:43:50 AMAPASS
Phone #: ###-#### Inspection requested via web by robert goodson