Inspections for the day of: Wednesday, October 10, 2012.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00168 ELE-Aging Inspection10/10/201210/10/201210/10/2012 2:43:06 PM DONE
waiting for contractor to call, still under construction
ELE10-00275 ELE-Aging Inspection10/10/201210/10/201210/10/2012 2:39:45 PM DONE
still under construction, waiting for call from previous calls
ELE10-00196 ELE-Aging Inspection10/10/201210/10/201210/10/2012 2:37:59 PM DONE
waiting for call, still under construction
ELE12-02480 Electrical Rough-In10/10/201210/10/201210/10/2012 2:32:01 PMPPASS
daniel Phone #: ###-#### ri ok
ELE12-02480 Final10/10/201210/10/201210/10/2012 2:31:48 PMPPASS
daniel Phone #: ###-#### ok final
ELE12-02383 Electrical Rough-In10/9/201210/10/201210/10/2012 1:54:01 PMPNR
Ron Phone #: ###-#### shall do make-up, ground metal boxes, flush outside box with finished surface
ELE12-02383 Permanent Service10/10/201210/10/201210/10/2012 1:22:31 PMPPASS
Ron Phone #: ###-#### p/s o/h n ok
ELE12-02237 Final10/9/201210/10/201210/10/2012 1:03:43 PMPPASS
Last of fixtures to be installed today. Phone #: ###-#### >> Inspection requested via web by Clint Tate ok final, signed card
ELE12-01368 Electrical Rough-In10/10/201210/10/201210/10/2012 12:18:28 PMPNH
Jon Phone #: ###-#### called, no answer, left card
ELE12-02211 Electrical Rough-In10/10/201210/10/201210/10/2012 11:44:00 AMPPASS
Ceiling only
Lockbox code 1946 Phone #: ###-#### >> Inspection requested via web by Jim Williams ok
ELE12-02421 Final10/9/201210/10/201210/10/2012 10:40:46 AMAPASS
Duane O''reilly is contact, ###-#### Phone #: ###-#### >> Inspection requested via web by Debby Ellis ok final
ELE12-02421 Electrical Rough-In10/10/201210/10/201210/10/2012 10:40:03 AMAPASS
Duane O''reilly is contact, ###-#### Phone #: ###-#### >> Inspection requested via web by Debby Ellis ri ok
ELE12-02392 Permanent Service10/9/201210/10/201210/10/2012 10:08:07 AMANR
kevin Phone #: ###-#### owner still wiring inside, will call for re-connect Friday
ELE12-02488 Electrical Rough-In10/9/201210/10/201210/10/2012 9:29:29 AMAPASS
walls Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack walls only ok cover
ELE12-02489 Electrical Rough-In10/9/201210/10/201210/10/2012 9:28:42 AMAPASS
walls Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack walls only ok cover
ELE12-02068 Final10/10/201210/10/201210/10/2012 8:50:24 AMAFAIL
code 8888 Phone #: ###-#### >> Inspection requested via web by kevin blackmon called, left message, left correction notice, NEC 210.52(D) shall supply receptale within 3' bath sink, 210.52(C) shall supply kitchen sink receptacle within 2' of sink, 210.52(A)(2) shall supply convience receptacle in wall space under bar type counter, BCC all lights shall operate such as pucks in hall
ELE12-02211 Electrical Rough-In10/10/201210/10/201210/10/2012 8:07:24 AMANH
ceiling only Phone #: ###-#### >> Inspection requested via web by Jim Williams left sticker, no one there, called, left message