ELE10-00168
| ELE-Aging Inspection | 10/10/2012 | 10/10/2012 | 10/10/2012 2:43:06 PM | | DONE |
|
|
waiting for contractor to call, still under construction
|
ELE10-00275
| ELE-Aging Inspection | 10/10/2012 | 10/10/2012 | 10/10/2012 2:39:45 PM | | DONE |
|
|
still under construction, waiting for call from previous calls
|
ELE10-00196
| ELE-Aging Inspection | 10/10/2012 | 10/10/2012 | 10/10/2012 2:37:59 PM | | DONE |
|
|
waiting for call, still under construction
|
ELE12-02480
| Electrical Rough-In | 10/10/2012 | 10/10/2012 | 10/10/2012 2:32:01 PM | P | PASS |
|
|
daniel Phone #: ###-#### ri ok
|
ELE12-02480
| Final | 10/10/2012 | 10/10/2012 | 10/10/2012 2:31:48 PM | P | PASS |
|
|
daniel Phone #: ###-#### ok final
|
ELE12-02383
| Electrical Rough-In | 10/9/2012 | 10/10/2012 | 10/10/2012 1:54:01 PM | P | NR |
|
|
Ron Phone #: ###-#### shall do make-up, ground metal boxes, flush outside box with finished surface
|
ELE12-02383
| Permanent Service | 10/10/2012 | 10/10/2012 | 10/10/2012 1:22:31 PM | P | PASS |
|
|
Ron Phone #: ###-#### p/s o/h n ok
|
ELE12-02237
| Final | 10/9/2012 | 10/10/2012 | 10/10/2012 1:03:43 PM | P | PASS |
|
|
Last of fixtures to be installed today. Phone #: ###-#### >> Inspection requested via web by Clint Tate ok final, signed card
|
ELE12-01368
| Electrical Rough-In | 10/10/2012 | 10/10/2012 | 10/10/2012 12:18:28 PM | P | NH |
|
|
Jon Phone #: ###-#### called, no answer, left card
|
ELE12-02211
| Electrical Rough-In | 10/10/2012 | 10/10/2012 | 10/10/2012 11:44:00 AM | P | PASS |
|
|
Ceiling only Lockbox code 1946 Phone #: ###-#### >> Inspection requested via web by Jim Williams ok
|
ELE12-02421
| Final | 10/9/2012 | 10/10/2012 | 10/10/2012 10:40:46 AM | A | PASS |
|
|
Duane O''reilly is contact, ###-#### Phone #: ###-#### >> Inspection requested via web by Debby Ellis ok final
|
ELE12-02421
| Electrical Rough-In | 10/10/2012 | 10/10/2012 | 10/10/2012 10:40:03 AM | A | PASS |
|
|
Duane O''reilly is contact, ###-#### Phone #: ###-#### >> Inspection requested via web by Debby Ellis ri ok
|
ELE12-02392
| Permanent Service | 10/9/2012 | 10/10/2012 | 10/10/2012 10:08:07 AM | A | NR |
|
|
kevin Phone #: ###-#### owner still wiring inside, will call for re-connect Friday
|
ELE12-02488
| Electrical Rough-In | 10/9/2012 | 10/10/2012 | 10/10/2012 9:29:29 AM | A | PASS |
|
|
walls Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack walls only ok cover
|
ELE12-02489
| Electrical Rough-In | 10/9/2012 | 10/10/2012 | 10/10/2012 9:28:42 AM | A | PASS |
|
|
walls Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack walls only ok cover
|
ELE12-02068
| Final | 10/10/2012 | 10/10/2012 | 10/10/2012 8:50:24 AM | A | FAIL |
|
|
code 8888 Phone #: ###-#### >> Inspection requested via web by kevin blackmon called, left message, left correction notice, NEC 210.52(D) shall supply receptale within 3' bath sink, 210.52(C) shall supply kitchen sink receptacle within 2' of sink, 210.52(A)(2) shall supply convience receptacle in wall space under bar type counter, BCC all lights shall operate such as pucks in hall
|
ELE12-02211
| Electrical Rough-In | 10/10/2012 | 10/10/2012 | 10/10/2012 8:07:24 AM | A | NH |
|
|
ceiling only Phone #: ###-#### >> Inspection requested via web by Jim Williams left sticker, no one there, called, left message
|