ESC09-00407
| General Inspection | 10/21/2009 | 10/21/2009 | 10/21/2009 3:47:00 PM | P | PASS |
|
|
looked ok
|
ESC09-00213
| General Inspection | 10/21/2009 | 10/21/2009 | 10/21/2009 3:45:01 PM | P | PASS |
|
|
looked ok
|
ESC09-00258
| General Inspection | 10/21/2009 | 10/21/2009 | 10/21/2009 3:44:21 PM | P | PASS |
|
|
looked ok
|
ESC09-00401
| General Inspection | 10/21/2009 | 10/21/2009 | 10/21/2009 3:42:35 PM | P | PASS |
|
|
looked ok
|
ELE09-02036
| Electrical Rough-In | 10/21/2009 | 10/21/2009 | 10/21/2009 3:38:16 PM | P | PASS |
|
|
Bob That islsnd is ready for cover and i have removed and sealed and taken care of the items on the ceiling we discussed. The rest of the work i will make availble for your review on final. Thanks Dave Phone #: ###-#### Internet Inspection Request from: jason shifflett ric ok, no esc this project
|
ELE09-02049
| Electrical Rough-In | 10/21/2009 | 10/21/2009 | 10/21/2009 2:56:35 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok, no esc this project
|
ELE09-02049
| Final | 10/21/2009 | 10/21/2009 | 10/21/2009 2:56:23 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final, no esc this project
|
ELE09-02008
| Rough-In Permanent Service | 10/20/2009 | 10/21/2009 | 10/21/2009 2:08:02 PM | P | FAIL |
|
|
Aly Phone #: ###-#### homeowner not doing work, called homeowner, 412, ipco, and city to void permit, told that electrical contractor shall permit and do work, no esc this project
|
ELE09-00845
| Electrical Rough-In | 10/21/2009 | 10/21/2009 | 10/21/2009 1:58:38 PM | P | PASS |
|
|
mike Phone #: ###-#### ric ok
|
ELE09-01695
| Final | 10/21/2009 | 10/21/2009 | 10/21/2009 12:45:56 PM | P | FAIL |
|
|
Daniel Phone #: ###-#### called, left correction notice, NEC 200.7 shall not use white for phase conductor at a/c, 406.4 shall securely mount receptacles, 422.11(A) shall not exceed rating of a/c nameplate for overcurrent protection, 210.52(C)(2)(4) shall add receptacle to left of sink in countertop space
|
ELE09-01886
| Rough-In Permanent Service | 10/20/2009 | 10/21/2009 | 10/21/2009 11:45:12 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Stephen Kren ric ok house and garage, p/s u/g n ok
|
ELE09-01887
| Rough-In Permanent Service | 10/20/2009 | 10/21/2009 | 10/21/2009 10:35:56 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Stephen Kren ric ok house and garage, p/s u/g n ok, no esc this project
|
ELE09-02047
| Electrical Rough-In | 10/20/2009 | 10/21/2009 | 10/21/2009 10:07:36 AM | A | FAIL |
|
|
Tom Phone #: ###-#### called, left correction notice, BCC all commercial wiring shall be in mc cable or conduit and wire- no nm cable, no esc this project
|
ELE09-01607
| Electrical Rough-In | 10/20/2009 | 10/21/2009 | 10/21/2009 9:13:46 AM | A | FAIL |
|
|
Josh Phone #: ###-#### called, left correction notice, NEC 300.14 shall provide minimum 6" free conductor length at boxes, 334.30 shall staple nm cable over panel within 12" of panel, 100.12(B) shall maintain integrity of conductor- no cuts or nicks thru insulation- by panel
|
ELE09-02041
| Conference | 10/20/2009 | 10/21/2009 | 10/21/2009 8:28:26 AM | A | CANC |
|
|
Jeff Pierce Phone #: ###-#### Internet Inspection Request from: Dave Friend see ri
|
ELE09-02041
| Electrical Rough-In | 10/21/2009 | 10/21/2009 | 10/21/2009 8:28:07 AM | A | FAIL |
|
|
Jeff Pierce Phone #: ###-#### Internet Inspection Request from: Dave Friend met contractot, left correction notice to owner, NEC 358.30 emt shall be securely fastened within 3' of termination, 725.25 abandoned low voltage cables shall be removed, 300.11(A) cables shall not be supported by ceiling, BCC no violations shall be retained
|