Inspections for the day of: Wednesday, November 27, 2013.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03222 Electrical Rough-In11/27/201311/27/201311/27/2013 3:24:11 PMPPASS
Chris is the contact his cell is ###-####. Phone #: ###-#### >> Inspection requested via web by Mike Basye ri ok anop, 2 walls, not 4, duct in floor, columns
ELE13-02323 Electrical Rough-In11/27/201311/27/201311/27/2013 2:49:38 PMPPASS
304 rough 305 rough 306 rough cover Phone #: ###-#### >> Inspection requested via web by fred lopez ok cover 3 units
ELE13-02835 Electrical Rough-In11/27/201311/27/201311/27/2013 2:48:35 PMPPASS
Need approval to cover trench. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok cover u/g house to garage
ELE13-03243 Final11/27/201311/27/201311/27/2013 2:02:13 PMPPASS
Dan Phone #: ###-#### ok final, signed card
ELE13-02410 Final11/27/201311/27/201311/27/2013 1:58:42 PMPFAIL
Addresses are garage codes Phone #: ###-#### >> Inspection requested via web by TOM BICANDI called, bathroom gfci protection shall operate
ELE13-02051 Final11/27/201311/27/201311/27/2013 1:20:05 PMPPASS
please give me a call half an hour before inspection so that I can meet you and let you in thanks shaun 941 6264 Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman ok final
ELE13-02987 Final11/27/201311/27/201311/27/2013 12:32:36 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Brad Baker ok final, signed card
ELE13-03241 Final11/26/201311/27/201311/27/2013 10:23:40 AMAPASS
Please call Mitch @ ###-#### approx. 45min before getting there & he will meet you for access. Installed heat tapes Phone #: ###-#### >> Inspection requested via web by Amie Rose ok final
ELE13-03241 Electrical Rough-In11/26/201311/27/201311/27/2013 10:08:17 AMAPASS
Please call Mitch @ ###-#### or ###-#### 45 mins before getting there & he will meet you for access. Heat tapes installed. Phone #: ###-#### >> Inspection requested via web by Amie Rose ri ok
ELE13-03288 Rough-In Permanent Service11/26/201311/27/201311/27/2013 9:40:02 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
ELE13-02932 Final11/26/201311/27/201311/27/2013 9:14:23 AMANR
>> Inspection requested via web by Terry Scott called, shall finish by adding faceplates, rest ok
ELE13-03311 Final11/26/201311/27/201311/27/2013 9:13:26 AMACANC
>> Inspection requested via web by Terry Scott see ri
ELE13-03311 Electrical Rough-In11/27/201311/27/201311/27/2013 9:13:15 AMAPASS
>> Inspection requested via web by Terry Scott ri ok
ELE13-02689 Final11/26/201311/27/201311/27/2013 8:37:50 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by George Pascua called, NEC 408.4 circuit directory shall be clear concise and evident for purpose such as room number for receptacles, 210.8(B)(5) receptacle within 6' of sink shall be gfci protected, 406.4(D) receptacle face shall be flush with or project from faceplate, BCC shall install bathroom receptacle, hall lights, and receptacles shall operate near break room, BCC shall post address or suite number
ELE13-03288 Rough-In Permanent Service11/22/201311/27/201311/26/2013 8:04:29 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk