Inspections for the day of: Wednesday, December 23, 2009.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-01162 ELE-Aging Inspection12/23/200912/23/200912/24/2009 1:55:05 PM NR
job still under construction
ELE08-00372 ELE-Aging Inspection12/23/200912/23/200912/24/2009 1:53:10 PM DONE
see final per jms
ELE09-01494 ELE-Aging Inspection12/23/200912/23/200912/24/2009 12:53:02 PM DONE
no activity, suc
ELE08-00262 ELE-Aging Inspection12/23/200912/23/200912/24/2009 12:24:01 PM DONE
no activity, see doc expire
ESC09-00501 General Inspection12/23/200912/23/200912/23/2009 4:05:29 PMPPART
looked ok, 460 will find out about rp
ELE09-02403 Final12/23/200912/23/200912/23/2009 3:48:46 PMPPASS
Mike Phone #: ###-#### ok to final, no esc this project
ELE09-02422 Electrical Rough-In12/23/200912/23/200912/23/2009 3:43:11 PMPPASS
Can you please call me ten minutes before you get there so I can see if I can meet you at the job. Thanks, Mark Phone #: ###-#### Internet Inspection Request from: Mark Hennequin called, left message, talked to builder, ri ok up and down, no esc this project
ESC09-00711 General Inspection12/23/200912/23/200912/23/2009 3:28:38 PMPPASS
looked ok
ESC09-00480 General Inspection12/23/200912/23/200912/23/2009 3:27:47 PMPPASS
looked ok
ELE09-02451 Final12/23/200912/23/200912/23/2009 2:32:32 PMPPASS
Phone #: ###-#### Internet Inspection Request from: PAT MILLER ok to final, no esc this project
ELE09-02181 Permanent Service12/23/200912/23/200912/23/2009 2:02:05 PMPFAIL
Could you please call me ten minutes before you get there to see if I can meet you if possible. Thanks, Mark Phone #: ###-#### Internet Inspection Request from: Mark Hennequin called, left message, left correction notice, NEC 334.15(B) nm cable shall be protected from physical damage at sub-panel, 110.26 shall provide work space about sub-panel, and no water pipe below service panel, 250.24(A) shall run gec to grounded electrode terminal bar, 250.53(G) electrodes shall be installed such that 8' of length is in contact with soil, no esc this project
ELE09-02260 Electrical Rough-In12/23/200912/23/200912/23/2009 1:01:44 PMPFAIL
TONY Phone #: ###-#### met electrician, left correction notice, BCC 4-05-33(A),(B) all equipment shall be listed by a nationally recognized testing laboratory, NEC 110.3(A) (1) equipment shall be suitable for installation and use in conformity with the provisions of this code
GCE09-00046 GCE-Rough-In12/22/200912/23/200912/23/2009 10:39:33 AMAPASS
Contact Zane @ ###-#### ri ok walls and ceiling
ELE09-02259 Electrical Rough-In12/22/200912/23/200912/23/2009 9:50:36 AMACANC
Jason- call 30 mins prior to going Phone #: ###-#### see conference
ELE09-02259 Conference12/23/200912/23/200912/23/2009 9:36:26 AMADONE
Jason- call 30 mins prior to going Phone #: ###-#### talked to owner about free length of conductor, no broken boxes, 1 1/4", ground metal boxes, outside receptacle shall not be on kitchen small appliance circuit, told to fix and recall
ELE09-01814 Final12/23/200912/23/200912/23/2009 9:26:41 AMAPASS
Please give me half an hour notice so that I can insure access Thanks Shaun ###-#### Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman owner moved in, could not check every receptacle, ok to final
ELE09-01101 Final12/22/200912/23/200912/23/2009 8:31:15 AMAPASS
Contact: Neil Ramsey Phone #: ###-#### Internet Inspection Request from: Deb Gooden ok to final, no card to sign, no esc this project