Inspections for the day of: Tuesday, December 4, 2012.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02586 ELE-Aging Inspection12/4/201212/4/201212/10/2012 3:42:53 PM DONE
see final
ELE10-02823 ELE-Aging Inspection12/4/201212/4/201212/6/2012 9:58:32 AM DONE
contractor hasn't asked for final, still under construction
ELE12-02890 Temporary Service12/4/201212/4/201212/4/2012 2:55:46 PMPCANC
>> Inspection requested via web by joel smith see p/s
ELE12-02890 Permanent Service12/4/201212/4/201212/4/2012 2:55:27 PMPPASS
>> Inspection requested via web by joel smith p/s o/h rec ok
ELE12-01368 Electrical Rough-In12/4/201212/4/201212/4/2012 2:39:43 PMPFAIL
Jon-Please call at least 30 mins prior to inspection Phone #: ###-#### met owner, corrections not made, shall provide 6" free conductor length, nailplates, shall not staple nm on edge, shall not reduce ground size, told to fix and recall, should add 4 rooms to permit
ELE12-02696 Electrical Rough-In12/4/201212/4/201212/4/2012 1:57:31 PMPPASS
inspect floor heat cable. please call me to set up time to meet this afternoon. Thanks
Bob Schroder Phone #: ###-#### >> Inspection requested via web by Julie Schroder ok cover floor heat
ELE12-02672 Final12/4/201212/4/201212/4/2012 1:16:59 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Thomas Jenkins called, ok final
ELE12-02924 Permanent Service12/4/201212/4/201212/4/2012 12:15:57 PMPPASS
Electrical panel inspection to restore power, power has been disconnected for more than a year. Phone #: ###-#### >> Inspection requested via web by Harvey Reyna p/s o/h rec ok
ELE12-02924 Final12/4/201212/4/201212/4/2012 12:13:48 PMPPASS
Electrical panel inspection to restore power, power has been disconnected for more than a year. Phone #: ###-#### >> Inspection requested via web by Harvey Reyna ok final
ELE12-02881 Electrical Rough-In12/3/201212/4/201212/4/2012 12:05:43 PMPFAIL
Jon. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy called, left message, trench not opened, told to recall
ELE12-02920 Rough-In Permanent Service12/3/201212/4/201212/4/2012 10:18:12 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Richard Gratiot ri ok, p/s u/g n ok
ELE12-02898 Rough-In Permanent Service12/4/201212/4/201212/4/2012 9:52:33 AMAPASS
Call Dene with any questions
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser ri ok, p/s u/g n ok
ELE12-02251 Final12/3/201212/4/201212/4/2012 9:07:01 AMAPASS
Garage entrance code 1968E Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
ELE12-02895 Temporary Service12/3/201212/4/201212/4/2012 8:37:09 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Alan Lusk called, no job id sticker, can't read address, shall provide gfci protection for 50A receptacle
ELE11-02855 Electrical Rough-In12/3/201212/4/201212/4/2012 8:06:26 AMAPASS
Steve Phone #: ###-#### ok cover ceilings anop, should be last of ceilings