Inspections for the day of: Friday, September 17, 2010.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01360 ELE-Aging Inspection9/17/20109/17/20109/20/2010 6:21:23 AM DONE
suc
ELE09-00253 ELE-Aging Inspection9/17/20109/17/20109/20/2010 6:20:38 AM DONE
see doc expire
ELE10-02024 Electrical Rough-In9/16/20109/17/20109/17/2010 2:57:01 PMPCANC
Contact: Shane Korte - Late afternoon inspection if possible please Phone #: ###-#### >> Inspection requested via web by Deb Gooden yalked to electrician, needed several more hours before ready, will call for early Monday
ELE10-01957 Electrical Rough-In9/16/20109/17/20109/17/2010 2:52:06 PMAFAIL
Reham Phone #: ###-#### met owner, needs to provide 1 1/4" for holes and nm cable on studs, staple nm within 8" of box
ELE10-02065 Final9/17/20109/17/20109/17/2010 2:33:01 PMAFAIL
ALL THE UP TO THE END OF 36TH Phone #: ###-#### >> Inspection requested via web by Bob Glenn called, left correction notice, NEC 250.24(C) shall install main bonding jumper, fee due Note corrections shall be made in 5 working days
ELE10-02063 Rough-In Permanent Service9/16/20109/17/20109/17/2010 1:57:25 PMAFAIL
call for access Phone #: ###-#### >> Inspection requested via web by John VanZandt called left correction notice, NEC 408.4 shall provide circuit directory, 110.12(A) shall close openings in panel, 250.52(A)(1) shall use interior metal water piping for grounding electrode, 250.56 rod electrodes shall be 6' apart, 210.52 shall provide receptace for closet wall over 2', 110.14(A) shall connect all strands copper to lug at service, 334.15 shall protect cable at water heater and provide disconnect, NOTE corrections shall be made in 5 working days
ELE09-01136 Electrical Rough-In9/16/20109/17/20109/17/2010 1:01:51 PMAPASS
Chauncey Phone #: ###-#### corrections made, ri ok
ELE10-01354 Permanent Service9/16/20109/17/20109/17/2010 12:01:39 PMPPASS
Nick is the contact his no. is ###-####. Phone #: ###-#### >> Inspection requested via web by Shawna Gates p/s u/g rec ok
ELE10-01611 Final9/16/20109/17/20109/17/2010 11:33:05 AMAPART
Please contact our Wireman Rod at ###-#### at the site and he will escort you to the 2ND Floor. We would like a Final inspection for the work completed throughout the 2ND Floor with the exception of the Library. Thank you. Phone #: ###-#### >> Inspection requested via web by Clint Tate ok for all but library, panel signs, no card
ELE10-01818 Electrical Rough-In9/16/20109/17/20109/17/2010 11:01:45 AMAPASS
wiring for the garage outback, the code to get in is 1221, any questions please call, thx, Terry W. Phone #: ###-#### >> Inspection requested via web by Stephen Kren ri garage only- need service equipment, grounding and inspection, called contractor
ELE10-01767 Final9/17/20109/17/20109/17/2010 8:25:36 AMADONE
cell ###-#### Phone #: ###-#### >> Inspection requested via web by Mark M see prior request, 9-16-10