Inspections for the day of: Wednesday, September 8, 2010.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01639 Electrical Rough-In9/8/20109/8/20109/9/2010 12:55:38 PMPFAIL
Ceiling cover and service Phone #: ###-#### >> Inspection requested via web by Ron Zimmerman open boxes, fa people need to finish work in ceiling, remove abandoned lv wiring, provide box supports, close openings in boxes, shall add disconnect for transformer secondary per NEC240.21
ELE10-00946 ELE-Aging Inspection9/8/20109/8/20109/9/2010 6:29:57 AM DONE
suc
ELE09-02485 ELE-Aging Inspection9/8/20109/8/20109/9/2010 6:28:23 AM DONE
see doc expire
ELE09-00033 ELE-Aging Inspection9/8/20109/8/20109/9/2010 6:26:51 AM DONE
see doc expire
ELE10-01964 Electrical Rough-In9/8/20109/8/20109/8/2010 2:57:57 PMPPASS
Jim ###-#### ri ok
ELE10-01966 Permanent Service9/8/20109/8/20109/8/2010 2:57:28 PMPPASS
p/s o/h rec ok, will call for final in am
ELE10-01963 Permanent Service9/8/20109/8/20109/8/2010 2:56:18 PMPPASS
John Phone #: ###-#### p/s o/h rec (new location) ok
ELE10-01963 Electrical Rough-In9/8/20109/8/20109/8/2010 2:56:17 PMPPASS
John Phone #: ###-#### ri ok
ELE10-01963 Electrical Rough-In9/8/20109/8/20109/8/2010 2:56:08 PMPPASS
John Phone #: ###-#### ri ok
ELE10-01948 Final9/8/20109/8/20109/8/2010 2:01:04 PMPCANC
Replaced 100amp service due to wind knocking down mast of existing service. Service is at the rear of the home. The gate to the back is on the left side of the house. Phone #: ###-#### >> Inspection requested via web by Billy Ellison wrong type request, see p/s
ELE10-01948 Permanent Service9/8/20109/8/20109/8/2010 1:46:49 PMPPASS
Replaced 100amp service due to wind knocking down mast of existing service. Service is at the rear of the home. The gate to the back is on the left side of the house. Phone #: ###-#### >> Inspection requested via web by Billy Ellison p/s o/h rec ok, check grounding at final
ELE10-01909 Electrical Rough-In9/8/20109/8/20109/8/2010 1:06:55 PMPFAIL
Dan Phone #: ###-#### left correction notice, BCC all make-up shall be done, NEC 250.86 shall have ground screws in metal boxes, 110.12(A) shall close unused openings, 210.52 shall meet outlet spacing, Note: corrections shall be made within 5 working days
ELE10-01957 Conference9/7/20109/8/20109/8/2010 12:14:21 PMADONE
Reham ###-#### talked about wiring garage and who to do wiring, call for ri for garage and u/g
ELE10-01955 Temporary Service9/7/20109/8/20109/8/2010 11:58:29 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE10-01636 Final9/2/20109/8/20109/8/2010 11:32:44 AMAPASS
Call Ginger ###-#### when on way for access please. Thanks, Andrea. Phone #: ###-#### x0000 >> Inspection requested via web by Andrea Creek called, ok final
ELE10-01944 Final9/7/20109/8/20109/8/2010 10:23:22 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Jim Snodgrass called, ok final, signed card
ELE10-01962 Electrical Rough-In9/7/20109/8/20109/8/2010 9:37:29 AMAPASS
MIke Phone #: ###-#### ok cover ceiling
ELE10-01625 Electrical Rough-In9/7/20109/8/20109/8/2010 9:11:32 AMAPASS
19th Floor Ceiling Inspection. Please Call Steve Harris ###-####. Phone #: ###-#### >> Inspection requested via web by Kevin Perez ok
ELE10-01054 Final9/7/20109/8/20109/8/2010 8:32:15 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Dan Rohl called, ok final
ELE09-00008 ELE-Aging Inspection9/8/20109/8/20109/8/2010 6:50:51 AM DONE
see final
ELE09-00008 Final9/8/20109/8/20109/8/2010 6:50:34 AMAPASS
ok final
ELE10-00053 ELE-Aging Inspection9/8/20109/8/20109/8/2010 6:45:58 AM DONE
see doc expire
ELE10-00053 DOC - Permit Expired9/8/20109/8/20109/8/2010 6:45:45 AMAPASS
no activity
ELE10-01953 Electrical Rough-In9/7/20109/8/20109/7/2010 9:17:07 PMACANC
Underlab conduit inspection Phone #: ###-#### >> Inspection requested via web by Steve Craig Inspection cancelled from web by: Steve Craig