ELE14-03271
| Permanent Service | 12/1/2014 | 12/1/2014 | 12/1/2014 4:12:10 PM | P | PASS |
|
|
Aaron// ###-####- Per Daryl Degrange PS, UG, RC, OK
|
ELE14-03274
| Electrical Rough-In | 12/1/2014 | 12/1/2014 | 12/1/2014 1:42:26 PM | P | PASS |
|
|
Wall Cover. Home owner''s name is Ed. Rough in remaining electrical in basement. Original rough in was done during original build. Call Buster (RME) with any questions. Thanks Phone #: ###-#### Inspection requested via web by Buster Bowen Basement RI ok to cover
|
ELE14-03303
| Final | 12/1/2014 | 12/1/2014 | 12/1/2014 1:18:31 PM | P | PASS |
|
|
Brent Phone #: ###-#### FInal OK
|
ELE14-03303
| Permanent Service | 12/1/2014 | 12/1/2014 | 12/1/2014 1:18:17 PM | P | PASS |
|
|
Brent Phone #: ###-#### PS, OH, N, OK
|
ELE14-03296
| Temporary Service | 12/1/2014 | 12/1/2014 | 12/1/2014 12:49:00 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov wrong inspection
|
ELE14-03296
| Rough-In Permanent Service | 12/1/2014 | 12/1/2014 | 12/1/2014 12:47:01 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 210.52 outlet required hallway over 10 feet, entry 300.4A(1) nm cable protection through bored holes, nail plates BCC 4.05 all work ready for inspection requested, missing mud rings
|
ELE14-03295
| Rough-In Permanent Service | 12/1/2014 | 12/1/2014 | 12/1/2014 12:45:25 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov wrong inspection
|
ELE14-03295
| Temporary Service | 12/1/2014 | 12/1/2014 | 12/1/2014 12:45:11 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 590.6 GFI protections required for construction service
|
ELE14-02283
| Final | 12/1/2014 | 12/1/2014 | 12/1/2014 11:39:09 AM | P | PASS |
|
|
access is lock box, 8125 Phone #: ###-#### Inspection requested via web by Charles Davis FInal OK
|
ELE12-03055
| ELE-Aging Inspection | 12/1/2014 | 12/1/2014 | 12/1/2014 8:44:45 AM | | DONE |
|
|
Spoke to contractor, project has stopped. Watch for new electrical contractor on project
|
ELE12-02398
| ELE-Aging Inspection | 12/1/2014 | 12/1/2014 | 12/1/2014 8:34:57 AM | | DONE |
|
|
Spoke to Terry, he will try to arrange for final
|
ELE14-03293
| Permanent Service | 11/30/2014 | 12/1/2014 | 12/1/2014 8:26:07 AM | A | DONE |
|
|
Phone #: ###-#### Inspection requested via web by steve sellers PS, OH, N, OK
|
ELE14-03288
| Permanent Service | 12/1/2014 | 12/1/2014 | 12/1/2014 12:00:00 AM | P | PASS |
|
|
Aaron// ###-####- Per Daryl Degrange PS, UG, RC, OK
|