Inspections for the day of: Monday, December 1, 2014.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-03271 Permanent Service12/1/201412/1/201412/1/2014 4:12:10 PMPPASS
Aaron// ###-####- Per Daryl Degrange
PS, UG, RC, OK
ELE14-03274 Electrical Rough-In12/1/201412/1/201412/1/2014 1:42:26 PMPPASS
Wall Cover. Home owner''s name is Ed. Rough in remaining electrical in basement. Original rough in was done during original build. Call Buster (RME) with any questions. Thanks Phone #: ###-#### Inspection requested via web by Buster Bowen
Basement RI ok to cover
ELE14-03303 Final12/1/201412/1/201412/1/2014 1:18:31 PMPPASS
Brent Phone #: ###-####
FInal OK
ELE14-03303 Permanent Service12/1/201412/1/201412/1/2014 1:18:17 PMPPASS
Brent Phone #: ###-####
PS, OH, N, OK
ELE14-03296 Temporary Service12/1/201412/1/201412/1/2014 12:49:00 PMPCANC
Phone #: ###-#### Inspection requested via web by daniel bibikov
wrong inspection
ELE14-03296 Rough-In Permanent Service12/1/201412/1/201412/1/2014 12:47:01 PMPFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
210.52 outlet required hallway over 10 feet, entry
300.4A(1) nm cable protection through bored holes, nail plates
BCC 4.05 all work ready for inspection requested, missing mud rings
ELE14-03295 Rough-In Permanent Service12/1/201412/1/201412/1/2014 12:45:25 PMPCANC
Phone #: ###-#### Inspection requested via web by daniel bibikov
wrong inspection
ELE14-03295 Temporary Service12/1/201412/1/201412/1/2014 12:45:11 PMPFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
590.6 GFI protections required for construction service
ELE14-02283 Final12/1/201412/1/201412/1/2014 11:39:09 AMPPASS
access is lock box, 8125 Phone #: ###-#### Inspection requested via web by Charles Davis
FInal OK
ELE12-03055 ELE-Aging Inspection12/1/201412/1/201412/1/2014 8:44:45 AM DONE
Spoke to contractor, project has stopped. Watch for new electrical contractor on project
ELE12-02398 ELE-Aging Inspection12/1/201412/1/201412/1/2014 8:34:57 AM DONE
Spoke to Terry, he will try to arrange for final
ELE14-03293 Permanent Service11/30/201412/1/201412/1/2014 8:26:07 AMADONE
Phone #: ###-#### Inspection requested via web by steve sellers
PS, OH, N, OK
ELE14-03288 Permanent Service12/1/201412/1/201412/1/2014 12:00:00 AMPPASS
Aaron// ###-####- Per Daryl Degrange
PS, UG, RC, OK