ELE14-03420
| Rough-In Permanent Service | 12/15/2014 | 12/16/2014 | 12/16/2014 3:41:02 PM | P | FAIL |
|
|
reinspect service clearances, recess cans outside, crawl access, kitchen island wiring Phone #: ###-#### Inspection requested via web by Emmet Bushman WUI zone fire area, recessed can boxes must be fire caulked at openings
|
ELE12-02467
| ELE-Aging Inspection | 12/16/2014 | 12/16/2014 | 12/16/2014 1:22:55 PM | | DONE |
|
|
Spoke to John, will research project for final
|
ELE12-02504
| ELE-Aging Inspection | 12/16/2014 | 12/16/2014 | 12/16/2014 1:19:26 PM | | DONE |
|
|
Spoke to company, they will investigate project
|
ELE14-03331
| Final | 12/16/2014 | 12/16/2014 | 12/16/2014 1:16:08 PM | P | PASS |
|
|
The access code is 3902 The panel cover is secured and ready for the final insp, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Final OK
|
ELE14-03153
| Final | 12/16/2014 | 12/16/2014 | 12/16/2014 1:01:57 PM | P | PASS |
|
|
Please call half hour before. Need to meet you with key. Thanks Phone #: ###-#### Inspection requested via web by mark hood Final OK
|
ELE14-02751
| Final | 12/15/2014 | 12/16/2014 | 12/16/2014 12:19:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jarod Murray Final OK
|
ELE14-03447
| Electrical Rough-In | 12/15/2014 | 12/16/2014 | 12/16/2014 10:58:27 AM | A | FAIL |
|
|
Any questions, please call Darrel Kubik ###-#### Phone #: ###-#### Inspection requested via web by Charmel Kubik Phone number listed is non-working 300.4A1 Nm through bored holes shall have protection where edge of hole is less than 1 1/4 inch from edge of framing member
BCC all work shall be finished and ready for inspection, wire and box hanging directly from ceilning and not made up
|
ELE14-02853
| Conference | 12/15/2014 | 12/16/2014 | 12/16/2014 10:13:03 AM | A | DONE |
|
|
discuss usable wall space Phone #: ###-#### Inspection requested via web by ERIC CENTERS Open railing wall space, discussed useable wall space with concrete floor, contractor to put outlet at both ends of open rail to cover wall space.
|
ELE14-03452
| Final | 12/15/2014 | 12/16/2014 | 12/16/2014 9:37:12 AM | A | PASS |
|
|
Shop at southeast of property 4 8'' fluorescents and 2 coaches Phone #: ###-#### Inspection requested via web by Cindie Swaim Final OK
|
ELE14-01776
| Final | 12/15/2014 | 12/16/2014 | 12/16/2014 9:23:32 AM | A | PASS |
|
|
Inspection requested via web by steve ragan Final OK
|
ELE14-02464
| Final | 12/15/2014 | 12/16/2014 | 12/16/2014 9:01:24 AM | A | FAIL |
|
|
Garage code is JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson 422.30 Disconnecting means required on all permanently installed appliances 250.148 metal boxes shall be grounded my means of grounding screw left message for Zane
|