GCE14-00207
| GCE-Temporary Service | 12/17/2014 | 12/17/2014 | 12/17/2014 2:38:46 PM | P | PASS |
|
|
Kevin ###-#### - temp pole insp. temp pole that sits in front of Id Pow transformer #TW-14 TS, UG, N, OK
|
ELE14-03369
| Electrical Rough-In | 12/17/2014 | 12/17/2014 | 12/17/2014 2:29:07 PM | P | PASS |
|
|
Mark Phone #: ###-#### corrections made, RI OK
|
ELE14-03229
| Rough-In Permanent Service | 12/17/2014 | 12/17/2014 | 12/17/2014 2:17:50 PM | P | FAIL |
|
|
Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren 310.15B 4/0 AL SER, 60*, max amp rating is 150 300.4 bored holes, nm shall be protected through bored holes with less than 1 1/4 inch to framing member edge 210.70.3 lighting outlets required, attic space with equipment requiring servicing 334.30 nm cable shall be supported at intervals not exceeding 4 1/2 foot 320.23 NM shall be protected withing 6 feet of attic access spoke to Terry
|
ELE14-03430
| Permanent Service | 12/17/2014 | 12/17/2014 | 12/17/2014 1:08:11 PM | P | PASS |
|
|
If you have any questions, please call Luke at ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan PS, OH, N, oK
|
ELE11-02792
| ELE-Aging Inspection | 12/17/2014 | 12/17/2014 | 12/17/2014 11:09:15 AM | | DONE |
|
|
Spoke to contractor,
|
ELE14-03447
| Rough-In Permanent Service | 12/17/2014 | 12/17/2014 | 12/17/2014 11:06:10 AM | A | PASS |
|
|
Please call Darrel Kubik ###-#### - the contractor scheduled to have the cement delivered this morning at 10:00 am and would like to have the inspection done before it arrives. Thank you Phone #: ###-#### Inspection requested via web by Charmel Kubik Corrections made, RI OK poured ground wire in concrete, ok to cover, PS, UG, N, OK
|
ELE14-03447
| Electrical Rough-In | 12/16/2014 | 12/17/2014 | 12/17/2014 11:05:16 AM | A | CANC |
|
|
Please call Darrel Kubik ###-####(ASAP). The contractor has scheduled to have the concrete poured at 10:00am and the inspection will need to be done before the concrete is poured.. Thank you Phone #: ###-#### Inspection requested via web by Charmel Kubik Called for 2 inspections, cancelled this one, see rough in permanent service
|
ELE14-03369
| Electrical Rough-In | 12/16/2014 | 12/17/2014 | 12/17/2014 10:38:52 AM | A | FAIL |
|
|
Mark Phone #: ###-#### Daryl DeGrange spoke to contractor, not all corrections have been addressed.
|
ELE13-02994
| ELE-Request for Extension | 12/16/2014 | 12/17/2014 | 12/17/2014 9:52:12 AM | A | PASS |
|
|
Mike Phone #: ###-#### Spoke to homeowner, they are moving forward with the renovation, and plan to have RI ready to inspect in near future. Extension given.
|
ELE13-03535
| Final | 12/15/2014 | 12/17/2014 | 12/17/2014 9:45:24 AM | A | PASS |
|
|
Call prior to going Phone #: 2088661213 >> Inspection requested via mobile web by Todd Nelson corrections made, final ok
|
ELE14-03466
| Temporary Service | 12/16/2014 | 12/17/2014 | 12/17/2014 9:26:45 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman 590.6 GFI protection required for temporary power to construction sites called Emmett
|
ELE14-02613
| Final | 12/16/2014 | 12/17/2014 | 12/17/2014 9:11:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard FInal OK
|
ELE14-03229
| Rough-In Permanent Service | 12/16/2014 | 12/17/2014 | 12/17/2014 7:26:40 AM | A | CANC |
|
|
Any questions please let me know, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren Inspection cancelled from web by: Stephen Kren
|