Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-02362 Electrical Rough-In2/17/20152/18/20152/18/2015 3:12:03 PMPPASS
We are requesting a ceiling cover inspection for tomorrow 2/18/15 in the pm. Our contact is Luke @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
Ceiling cover ok, 5 rooms
ELE15-00151 Electrical Rough-In2/18/20152/18/20152/18/2015 2:34:30 PMPPASS
Can you please call ahead so I can make sure the house is unlocked for you if I am not there. Thanks, Mark Phone #: ###-#### Inspection requested via web by Mark Hennequin
RI OK to cover, kitchen and bath area, basement romex will need strapping and securing for final
ELE15-00264 Rough-In Permanent Service2/18/20152/18/20152/18/2015 2:13:06 PMPPASS
Corrections have been made Phone #: ###-#### Inspection requested via web by Shaun Kirkman
corrections made, RI OK, PS, UG, N, OK
ELE12-01598 Final2/17/20152/18/20152/18/2015 1:43:40 PMPPASS
Jennifer-call for access Phone #: ###-####
Final OK
ELE14-03505 Final2/18/20152/18/20152/18/2015 1:27:41 PMPPASS
Access from back ally Phone #: ###-#### Inspection requested via web by Brad Girard
FInal OK
ELE15-00386 Conference2/18/20152/18/20152/18/2015 1:10:16 PMADONE
Questions about outlet locations. Phone #: ###-#### Inspection requested via web by Eric Brown
Discussed outlet placement in wet bar area, flat countertop with sliding window all the way to countertop. WHen window is fully open, outlets to each side will be within 2 foot of wall opening.
ELE14-03475 Final2/18/20152/18/20152/18/2015 12:42:59 PMANR
Phone #: ###-#### Inspection requested via web by Darryn Coburn
BCC 4.5.26 Trim out inspection, all items need to be working and installed.
ELE12-00913 ELE-Aging Inspection2/18/20152/18/20152/18/2015 11:49:30 AM DONE
Too busy
ELE12-02301 ELE-Aging Inspection2/18/20152/18/20152/18/2015 11:48:49 AM DONE
Too Busy
ELE14-03384 Final2/17/20152/18/20152/18/2015 11:47:17 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn
called Darryn
110.3.B listed or labeled equipment shall be installed in accordance with instructions, lockouts all fell off with panel cover
110.12 A Unused openings shall be closed, panel
210.5 Ungrounded conductors shall be permanently identified
422.11 e overcurrent protection shall not exceed that marked on appliance
408.4 Every circuit shall be legibly identified to its purpose, and accurately identified.
ELE14-03544 Rough-In Permanent Service2/17/20152/18/20152/18/2015 11:01:35 AMAPASS
Kevin Phone #: ###-####
RI OK, PS, UG, N< OK
ELE14-03447 Electrical Rough-In2/17/20152/18/20152/18/2015 10:34:14 AMAPASS
Rough in inspection for floor heat - You can call Darrel Kubik @ ###-#### Phone #: ###-#### Inspection requested via web by Charmel Kubik
Floor heat cable, upstairs master bath OK to cover
ELE14-02968 Final2/17/20152/18/20152/18/2015 10:26:33 AMAFAIL
Fred// please call before Phone #: ###-####
Met homeowner, upstairs receptacles required to be tamper resistant, all dwellings.
ELE15-00198 Final2/17/20152/18/20152/18/2015 10:15:08 AMAFAIL
back shop is open Phone #: ###-#### Inspection requested via web by David Nelson
contractors voice mail was full, could not leave message
408.4 every circuit shall be legibly identified for its purpose
334.12 B 4 NM cable not permitted in wet or damp locations
422.11 overcurrent protections device rating shall not exceed rating marked on the appliance
312.5 C cable shal l be secured to the cabinet
ELE14-03296 Final2/18/20152/18/20152/18/2015 9:39:19 AMAFAIL
Garage code 3283
Thank you Phone #: ###-#### Inspection requested via web by daniel bibikov
BCC 4.05.26 Trim out inspections, all items are to be working, outlet in master bath has no power
BCC
ELE15-00412 Temporary Service2/16/20152/18/20152/18/2015 8:36:53 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt
TS, UG, N, OK