Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-00492 Rough-In Permanent Service2/25/20152/25/20152/26/2015 12:52:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason Wicks
Kitchen OK to cover, PS, OH, RC, OK
ELE15-00450 Temporary Service2/24/20152/25/20152/25/2015 3:03:15 PMPPART
brian Phone #: ###-####
inspection on meter to get power, still need to see wiring to trailers.
TS, UG, N, OK
ELE09-02259 ELE-Aging Inspection2/25/20152/25/20152/25/2015 2:43:29 PM DONE
left message
ELE10-01957 ELE-Aging Inspection2/25/20152/25/20152/25/2015 2:40:05 PM DONE
Spoke to owner, still under construction, but close
ELE14-03285 Electrical Rough-In2/25/20152/25/20152/25/2015 2:38:11 PMPPASS
Eric Phone #: ###-####
corrections made, RI OK
ELE14-03458 Final2/25/20152/25/20152/25/2015 2:25:05 PMPCANC
ROUGH-IN ON GARAGE Phone #: ###-#### Inspection requested via web by John VanZandt
Wrong inspection, needed RI not final
ELE14-03458 Electrical Rough-In2/25/20152/25/20152/25/2015 2:24:23 PMPPASS
ROUGH-IN ON GARAGE Phone #: ###-#### Inspection requested via web by John VanZandt


OK to cover Garage,

For service to garage, 250.32 (B) Ungrounded Systems. The equipment of an ungrounded
separately derived system shall be grounded and bonded as
specified in 250.30(B)(1) through (B)(3).
(1) Grounding Electrode Conductor. A grounding electrode
conductor, sized in accordance with 250.66 for the
largest derived ungrounded conductor (s) or set of derived
ungrounded conductors, shall be used to connect the metal
enclosures of the derived system to the grounding electrode
as specified in 250.30(A)(5) or (6), as applicable. This connection
shall be made at any point on the separately derived
system from the source to the first system disconnecting
means. If the source is located outside the building or structure
supplied, a grounding electrode connection shall be
made in compliance with 250.30(C).
ELE15-00488 Final2/24/20152/25/20152/25/2015 1:36:07 PMPFAIL
Wood spa on upper deck. Phone #: ###-#### Inspection requested via web by Kotton Corder
680.22 (3) Other Receptacles, Location. Other receptacles shall
be not less than 1.83 m (6 ft) from the inside walls of a
pool.
680.22. B (3) Existing Installations. Existing luminaires and lighting
outlets located less than 1.5 m (5 ft) measured horizontally
from the inside walls of a pool shall be not less than
1.5 m (5 ft) above the surface of the maximum water level,
shall be rigidly attached to the existing structure, and shall
be protected by a ground-fault circuit interrupter.
680.26 (7) Fixed Metal Parts. All fixed metal parts shall be bonded
including, but not limited to, metal-sheathed cables and raceways,
metal piping, metal awnings, metal fences, and metal
door and window frames
680.26(C) Pool Water. Where none of the bonded parts is in
direct connection with the pool water, the pool water shall
be in direct contact with an approved corrosion-resistant
conductive surface that exposes not less than 5800 mm2
(9 in.2) of surface area to the pool water at all times. The
conductive surface shall be located where it is not exposed
to physical damage or dislodgement during usual pool activities,
and it shall be bonded in accordance with
680.26(B)
ELE15-00487 Electrical Rough-In2/25/20152/25/20152/25/2015 12:33:52 PMPPASS
Phone #: ###-#### Inspection requested via web by John VanZandt
ri OK to cover, kitchen, master bath, laundry, new panel, misc basement areas, smokes
ELE14-03542 Final2/24/20152/25/20152/25/2015 10:54:00 AMAPASS
Call ###-#### for access Phone #: ###-#### Inspection requested via web by Heath Thomas
Final OK
ELE14-03540 Final2/24/20152/25/20152/25/2015 10:14:45 AMAPASS
Call ###-#### for access Phone #: ###-#### Inspection requested via web by Heath Thomas
FInal OK
ELE14-03296 Final2/24/20152/25/20152/25/2015 9:35:18 AMAPASS
Garage code 3283 thank you Phone #: ###-#### Inspection requested via web by daniel bibikovs
corrections made, Final OK
ELE14-03383 Final2/25/20152/25/20152/25/2015 9:16:19 AMAPASS
Please call Scott ###-#### 1/2 prior for access to the home. Phone #: ###-#### Inspection requested via web by Buster Bowen
FInal oK
ELE15-00069 Final2/25/20152/25/20152/25/2015 9:06:17 AMACANC
Rough in on office and bathroom remodel Phone #: ###-#### Inspection requested via web by daniel bibikov
needed ri
ELE15-00069 Electrical Rough-In2/25/20152/25/20152/25/2015 9:05:56 AMPPASS
Rough in on office and bathroom remodel Phone #: ###-#### Inspection requested via web by daniel bibikov
Called daniel to immedeiately remove grounded receptacles from ungrounded circuit.
RI OK to cover