Inspections for the day of: Monday, June 15, 2015.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02529 ELE-Aging Inspection6/15/20156/15/20156/22/2015 7:54:30 AM CANC
to busy
ELE13-01033 ELE-Aging Inspection6/15/20156/15/20156/22/2015 7:53:27 AM CANC
to busy
ELE12-02415 ELE-Aging Inspection6/15/20156/15/20156/22/2015 7:53:01 AM CANC
to busy
ELE15-01769 Electrical Rough-In6/15/20156/15/20156/15/2015 3:54:45 PMPPASS
CODE #1122 Phone #: ###-#### Inspection requested via web by Eric Schroeder
ELE15-01725 Permanent Service6/15/20156/15/20156/15/2015 3:17:25 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov p/s u/g n ok
ELE15-01770 Electrical Rough-In6/15/20156/15/20156/15/2015 3:13:08 PMPFAIL
Phone #: ###-#### Inspection requested via web by daniel 300.4 bored holes wire must mantain 1 1/4 from nearest edge 314.7 (c) not less then 1/4in of sheathing inside box or clamp 300.3 cables installed parrellel with framing must have 1 1/4 min from edge of framing member
ELE15-01477 Electrical Rough-In6/15/20156/15/20156/15/2015 1:58:27 PMPPASS
would like call ahead; Mike Phone #: ###-#### rough-in ok cover
ELE15-01772 Electrical Rough-In6/15/20156/15/20156/15/2015 1:29:32 PMPPASS
Please call half an hour in advance of inspection to insure access. Thanks Shaun 9416264 Phone #: ###-#### Inspection requested via web by Shaun Kirkman rough-in kitchen and 2nd floor office ok cover
ELE15-01775 Electrical Rough-In6/15/20156/15/20156/15/2015 1:10:39 PMPNR
lighting retrofit rough in for warehouse lights Phone #: ###-#### Inspection requested via web by Tim Dunlop not ready no wothing to inspect
ELE15-01771 Temporary Service6/15/20156/15/20156/15/2015 12:57:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Larry Richardson t/s o/h n ok
ELE15-01774 Electrical Rough-In6/15/20156/15/20156/15/2015 12:37:48 PMPCANC
Allan Phone #: ###-#### needed r/i and p/s
ELE15-01774 Rough-In Permanent Service6/15/20156/15/20156/15/2015 12:37:02 PMPPASS
Allan Phone #: ###-#### rough-in ok p/s u/g n ok
ELE15-01592 Permanent Service6/15/20156/15/20156/15/2015 12:14:15 PMAPASS
please call first thing this morning to schedule for service change inspection
rick ###-#### Phone #: ###-#### Inspection requested via web by mike brown p/s o/h n rec ok
ELE15-01754 Final6/11/20156/15/20156/15/2015 10:08:48 AMACANC
Lock box at back door, code is 7771, Powder room is located at front of house next to front entry. Edison circuit serves GFI''s in powder room and in other bathroom. Existing lighting circuit used for light and exhaust fan. Phone #: ###-#### Inspection requested via web by Troy Cobb needed rough-in
ELE15-01754 Electrical Rough-In6/15/20156/15/20156/15/2015 10:04:45 AMPPASS
Lock box at back door, code is 7771, Powder room is located at front of house next to front entry. Edison circuit serves GFI''s in powder room and in other bathroom. Existing lighting circuit used for light and exhaust fan. Phone #: ###-#### Inspection requested via web by Troy Cobb rough-in powder bath ok cover
ELE15-01768 Electrical Rough-In6/15/20156/15/20156/15/2015 9:50:40 AMAPASS
Please call 30 minutes before heading to the house I have to call home owner to meet you. Thank you Phone #: ###-#### Inspection requested via web by Jay Symonds addition to mstr bed ok cover
ELE15-01066 Electrical Rough-In6/14/20156/15/20156/15/2015 9:40:03 AMAPASS
Inspection for cover; Back of house, second floor deck. Builders are going to take out window/install new doorway onto deck. Siding is removed. Homeowner will be there. His name is Jim /

Inspect: Re-routed wires, added 2 exterior light, 1 switch, 1 outside outlet, 1 inside outlet for layout.
Thank you,
Lonnie Phone #: ###-#### Inspection requested via web by Lonnie Sorichta back patio off master rough-in ok cover
ELE15-00840 Electrical Rough-In6/14/20156/15/20156/15/2015 9:24:21 AMAPASS
Please inspect floor heat in master bathroom Phone #: ###-#### Inspection requested via web by Shaun Kirkman flr heat rough in ok cover
ELE14-03515 Final6/12/20156/15/20156/15/2015 9:23:21 AMAPASS
Phone #: ###-#### Inspection requested via web by kendall bender final ok