Inspections for the day of: Friday, June 17, 2016.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01360 Electrical Rough-In6/15/20166/17/20166/17/2016 3:16:01 PMPCANC
Final inspection on 200 AMP service scheduled for the same afternoon. Phone #: ###-#### Inspection requested via web by Steven Reames
not ready
ELE16-01591 Final6/15/20166/17/20166/17/2016 3:15:00 PMPCANC
Attempting to schedule rough-in/final inspection on hot tub portion around same time. Phone #: ###-#### Inspection requested via web by Steven Reames
needed r/i and not ready at this time
ELE16-01591 Electrical Rough-In6/17/20166/17/20166/17/2016 3:14:50 PMPPASS
Attempting to schedule rough-in/final inspection on hot tub portion around same time. Phone #: ###-#### Inspection requested via web by Steven Reames
underground for pool ok cover
ELE16-01873 Final6/17/20166/17/20166/17/2016 2:58:22 PMPCANC
final for electrical on the remodel Phone #: ###-#### Inspection requested via web by Shane Dale
Needed r/i
ELE16-01873 Electrical Rough-In6/17/20166/17/20166/17/2016 2:57:54 PMPFAIL
final for electrical on the remodel Phone #: ###-#### Inspection requested via web by Shane Dale
348.30 FMC shall be securely fastened within 12" of a box and not exceed 4 1/2'
300.4(2) notches in wood where a cable is ran through it shall have a listed nail plate to protect form physical damage
ELE16-01165 Electrical Rough-In6/17/20166/17/20166/17/2016 2:09:06 PMPPASS
Wall and soffit cover. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen
Walls and soffits as noted on print ok cover
ELE16-01902 Electrical Rough-In6/15/20166/17/20166/17/2016 1:49:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Patrick Paz
kitchen and laundry rough-in ok cover
ELE16-01686 Final6/17/20166/17/20166/17/2016 1:27:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Patrick Paz
Final for up bath ok
ELE16-01924 Conference6/17/20166/17/20166/17/2016 1:03:58 PMPDONE
Micah Phone #: ###-####
Discussed service change requirments. changing overhead to u/g. will call for another conference once has full scope of work figured out.
ELE16-01844 Final6/17/20166/17/20166/17/2016 11:57:19 AMPCANC
Please call general (Adam ###-####) before heading there. Phone #: ###-#### Inspection requested via web by Barbara Szurgot
Needed r/i
ELE16-01844 Electrical Rough-In6/17/20166/17/20166/17/2016 11:57:12 AMPPASS
Please call general (Adam ###-####) before heading there. Phone #: ###-#### Inspection requested via web by Barbara Szurgot
Kitchen rough-in ok cover
ELE16-00668 Final6/16/20166/17/20166/17/2016 11:43:05 AMAFAIL
Garage code is JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson
Master vanity lights need hung
410.10 lights within 8' of bathtub shall be listed and have proper lamp installed
ELE16-01884 Rough-In Permanent Service6/16/20166/17/20166/17/2016 11:23:18 AMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson
Rough-in ok cover p/s u/g n ok
ELE16-01257 Electrical Rough-In6/17/20166/17/20166/17/2016 10:49:05 AMAPASS
New addition, bathroom floor heat mat. Phone #: ###-#### Inspection requested via web by Jarod Murray
Master bath floor heat only ok cover
ELE16-01440 Permanent Service6/16/20166/17/20166/17/2016 10:28:06 AMAPASS
new panel to replace existing, need permanat service connection Phone #: ###-#### Inspection requested via web by JENNY EMEL
Second ground rod will be looked at for final ID design personnel stated overhead feed was fine p/s o/h rc ok
ELE16-01537 Electrical Rough-In6/16/20166/17/20166/17/2016 10:10:37 AMAPASS
Fourth floor ceilings only Phone #: ###-#### Inspection requested via web by mike brown
4th floor cielings ok cover
ELE16-01491 Electrical Rough-In6/16/20166/17/20166/17/2016 9:29:49 AMAPASS
We are requesting a ceiling rough-in inspection for tomorrow 6/17/16 about mid-morning if possible. Our contact is Rich @ ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate
Areas as noted on EC print cielings ok cover
ELE16-01418 Final6/16/20166/17/20166/17/2016 8:56:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Ryan Wake
Correction fixed final ok
ELE16-01717 Final6/16/20166/17/20166/17/2016 8:29:58 AMAPASS
key box is side or back of building by gas meters and code is 1512 Phone #: ###-#### Inspection requested via web by ron spen cer
Final for front two offices ok(cieling was existing that why there was no cieling inspection done)
ELE13-00373 ELE-Aging Inspection6/17/20166/17/20166/17/2016 7:31:01 AM CANC
too busy
ELE12-02580 ELE-Aging Inspection6/17/20166/17/20166/17/2016 7:30:40 AM CANC
too busy
ELE13-00755 ELE-Aging Inspection6/17/20166/17/20166/17/2016 7:30:21 AM CANC
too busy