ELE15-02257
| Temporary Service | 7/21/2015 | 7/22/2015 | 7/23/2015 12:58:10 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
|
ELE15-01698
| Final | 7/22/2015 | 7/22/2015 | 7/22/2015 2:39:09 PM | P | FAIL |
|
|
Homeowners will be on site. Phone #: ###-#### Inspection requested via web by Paula Gratiot 210.12 (a) arc fault protection for required for bedrooms
|
ELE15-02218
| Electrical Rough-In | 7/21/2015 | 7/22/2015 | 7/22/2015 2:09:34 PM | P | PASS |
|
|
I''ll be ready by noon. Phone #: ###-#### Inspection requested via web by Andy Derrick kitchen rough-in ok cover
|
ELE15-02015
| Electrical Rough-In | 7/21/2015 | 7/22/2015 | 7/22/2015 1:49:25 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JENNY EMEL cieling rough-in ok cover
|
ELE15-02183
| Final | 7/20/2015 | 7/22/2015 | 7/22/2015 1:17:51 PM | A | PASS |
|
|
Hey Eric, Just a heads up, the home owner will not be home, so give me a call a couple hours before you head out, and I''ll meet you there. 850.8965
But here''s what you''ll be checking out -
10 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 275 watt Suniva panels, ETL listed.
A single home run, in metal conduit, is ran from the solar array to the knife switch, located next to meter base on west side of home. From the knife switch to breaker in main panel, at the bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are permanently marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service grounding electrode in the main panel.
Thanks Phone #: ###-#### Inspection requested via web by Ryan King final for photovoltaic system ok
|
ELE15-02183
| Electrical Rough-In | 7/22/2015 | 7/22/2015 | 7/22/2015 1:17:11 PM | P | PASS |
|
|
Hey Eric, Just a heads up, the home owner will not be home, so give me a call a couple hours before you head out, and I''ll meet you there. 850.8965
But here''s what you''ll be checking out -
10 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 275 watt Suniva panels, ETL listed.
A single home run, in metal conduit, is ran from the solar array to the knife switch, located next to meter base on west side of home. From the knife switch to breaker in main panel, at the bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are permanently marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service grounding electrode in the main panel.
Thanks Phone #: ###-#### Inspection requested via web by Ryan King rough-in for photovoltaic verified ul listing and grounding ok
|
ELE15-01343
| Electrical Rough-In | 7/22/2015 | 7/22/2015 | 7/22/2015 12:37:57 PM | P | PASS |
|
|
Floor heat install After 2:00 if possible Phone #: ###-#### Inspection requested via web by Emmet Bushman rough-in master floor heat ok cover
|
ELE15-02020
| Final | 7/22/2015 | 7/22/2015 | 7/22/2015 12:23:11 PM | P | PASS |
|
|
Mitch Phone #: ###-#### service change final ok
|
ELE15-01704
| Electrical Rough-In | 7/22/2015 | 7/22/2015 | 7/22/2015 11:02:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jarod Murray rough-in ok cover
|
ELE15-02255
| Electrical Rough-In | 7/21/2015 | 7/22/2015 | 7/22/2015 10:42:59 AM | A | PASS |
|
|
Some one will be home, if you have any questions, please call Calvin. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan basement remodel rough-in ok cover
|
ELE15-02227
| Electrical Rough-In | 7/21/2015 | 7/22/2015 | 7/22/2015 10:23:06 AM | A | PASS |
|
|
Jim Phone #: ###-#### kitchen-dinning room-bath-back bedroom rough-in ok cover
|
ELE15-02099
| Permanent Service | 7/21/2015 | 7/22/2015 | 7/22/2015 10:01:39 AM | A | PASS |
|
|
Was pull for temp service when it should have been a Permanent Service. Fees are due before permit can be finaled. If questions please call Darly D ###-#### PermanPhone #: ###-#### Inspection requested via web by Krista Ratterree p/s o/h n ok
|
ELE15-02254
| Final | 7/21/2015 | 7/22/2015 | 7/22/2015 10:00:33 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov no access homeowner not home
|