Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01374 ELE-Aging Inspection9/1/20169/1/20169/2/2016 7:50:45 AM CANC
too busy
ELE13-01366 ELE-Aging Inspection9/1/20169/1/20169/2/2016 7:50:35 AM CANC
too busy
ELE13-01339 ELE-Aging Inspection9/1/20169/1/20169/2/2016 7:50:24 AM CANC
too busy
ELE13-01273 ELE-Aging Inspection9/1/20169/1/20169/2/2016 7:50:00 AM CANC
too busy
ELE16-00089 Final9/1/20169/1/20169/1/2016 2:16:40 PMPPART
4th floor temp occ ok
ELE16-00089 Electrical Rough-In9/1/20169/1/20169/1/2016 2:15:46 PMPPASS
Call Rafael for inspection of 4th floor Clearwater. Phone #: ###-#### Inspection requested via web by Rafael Castillo
GBAD level 3 transformer ok to energize, lobby ceiling ok cover other the area with core and shell permit wiring, it is marked on print.
ELE15-03901 Electrical Rough-In8/31/20169/1/20169/1/2016 2:13:59 PMPPASS
Call Pierce for inspection of office furniture connections on the 8th floor (partial only for the furniture on the 8th floor, more to come). Phone #: ###-#### Inspection requested via web by Rafael Castillo
verified connections and wiring of office furniture(plug testedas well) 8th floor N&W areas noted on print ok,E side still to needs to be finished.
ELE16-02439 Final8/31/20169/1/20169/1/2016 1:58:08 PMPPASS
Install 1 cantilever mounted wall sign reading Deli. ALL PRIMARY POWER BY OTHERS
Phone #: ###-#### Inspection requested via web by Ken Olsen
final ok
ELE16-02320 Final9/1/20169/1/20169/1/2016 12:32:30 PMPFAIL
Garage door will be unlocked out back Phone #: ###-#### Inspection requested via web by daniel bibikov
406.5 receptacles shall be securely mounted(washer and other recept in laundry in-op)
110.3(b) shall not exceed manufactors specifications (main for sub-panel is in a max load 50 amp location in main)
422.30 Disconnect required for dishwasher&furnace
ELE16-02730 Electrical Rough-In8/31/20169/1/20169/1/2016 11:47:39 AMPPASS
UG Early pm if possible please Phone #: ###-#### Inspection requested via web by Kerri Hamilton
s.w of building underground ok cover
ELE16-00089 Electrical Rough-In8/31/20169/1/20169/1/2016 11:01:15 AMANR
Call Rafael for TCO final of only the 4th floor in the Clearwater side of building. Phone #: ###-#### Inspection requested via web by Rafael Castillo
Will need blank covers on all lv boxes and trim out outlet for drinking fountain, field identification for panels as well
ELE16-01402 Final8/31/20169/1/20169/1/2016 10:51:57 AMAPASS
Install 1 free standing monument sign with Message Center. ALL PRIMARY POWER BY OTHERS. Phone #: ###-#### Inspection requested via web by Ken Olsen
monument sign final ok
ELE15-00495 Electrical Rough-In8/31/20169/1/20169/1/2016 10:51:25 AMAPASS
Wall cover inspection. 4th floor elevator shaft wall in GBAD.
Contact is Mark Gibson ###-#### Phone #: ###-#### Inspection requested via web by Toby Groves
4th floor elevator wall ok cover
ELE16-01134 Electrical Rough-In8/31/20169/1/20169/1/2016 12:00:00 AMAPASS
Stair 1, level 6 Phone #: ###-#### Inspection requested via web by Clint Tate
Discussed with Bobbi about layout with receptacles in rooms and having to comply with 210.52 for layout. Stair 1 level 6 walls ok cover