Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-04365 Plumbing Rough-in10/17/201810/17/201810/17/2018 3:53:29 PMPPASS
Ramajla Phone #: ###-####
PLM18-03523 Plumbing Rough-in10/17/201810/17/201810/17/2018 3:53:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Johansen-Need to fix reverse grade on vents and missing nailplates& fix leak on vent.
PLM18-01748 Final10/17/201810/17/201810/17/2018 2:52:15 PMPPASS
MEC18-04989 Pressure Test10/16/201810/17/201810/17/2018 2:33:36 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek-20 lb gas test fail.
MEC18-04989 Rough-in10/16/201810/17/201810/17/2018 2:33:15 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek-Missing jump duct in master & need to nailplate condensate.
PLM18-04368 Water and/or Sewer10/17/201810/17/201810/17/2018 2:31:19 PMPPASS
Inspection requested via web by Chase Morgan
PLM18-04368 DOC - Permit Finaled10/17/201810/17/201810/17/2018 2:31:10 PMPPASS
MEC18-03366 Final10/17/201810/17/201810/17/2018 1:55:29 PMPPASS
Garage code #2724 Phone #: ###-#### Inspection requested via web by Debbie Marino
PLM18-03158 Final10/16/201810/17/201810/17/2018 1:42:07 PMPPART
Partial final in servery area Phone #: ###-#### Inspection requested via web by RM Mechanical-Cold wells pass. Temp final ok.
PLM18-04364 Water and/or Sewer10/16/201810/17/201810/17/2018 12:46:22 PMPPASS
Darren Spiers is the foreman if you could give him a call prior to arriving it would be appreciated. Thank you Phone #: ###-#### Inspection requested via web by judy patton
PLM18-04364 DOC - Permit Finaled10/17/201810/17/201810/17/2018 12:46:13 PMPPASS
PLM18-01760 Water and/or Sewer10/17/201810/17/201810/17/2018 12:35:51 PMPPASS
PLM18-01760 DOC - Permit Finaled10/17/201810/17/201810/17/2018 12:35:37 PMPPASS
PLM18-03444 Final10/17/201810/17/201810/17/2018 12:35:20 PMPCANC
call for code Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM18-02295 Final10/16/201810/17/201810/17/2018 11:37:36 AMAPART
Partial Final on 12 of the north end units. Units will be open for inspection. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes-10 of the 12 north rooms pass. Rooms 103 & 104 require an airgap on the T&P above the floor drain.
MEC18-04824 Final10/16/201810/17/201810/17/2018 10:50:33 AMAFAIL
Please call customer prior to arrival ###-####. Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby-Need c/o sensor in basement hallway & need to test pvc flue.
MEC18-04967 Rough-in10/16/201810/17/201810/17/2018 10:36:37 AMAPASS
rough-in Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
MEC18-04967 Pressure Test10/16/201810/17/201810/17/2018 10:36:21 AMAPASS
Gas pipe, furnace flue pipe, water heater flue pipe. Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
MEC18-03129 Pressure Test10/16/201810/17/201810/17/2018 10:15:20 AMAPASS
Pressure test on gas line to pool heater - Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek-60 lb gas test pass.
PLM18-01263 Storm Drains10/16/201810/17/201810/17/2018 9:35:28 AMAPART
Phone #: ###-#### Inspection requested via web by JD Borges-Section of storm drain ok to cover. North side of building left. All piping still needs tested.
PLM18-02010 Final10/16/201810/17/201810/17/2018 9:27:39 AMAPASS
2624 enter Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
MEC18-04892 Rough-in10/16/201810/17/201810/17/2018 8:48:02 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
PLM18-03193 Final10/16/201810/17/201810/17/2018 8:38:43 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jason Gale-T&P requires an airgap above floor drain and no water to toilet on flow thru fire system ?
PLM18-04342 Sprinkler (Final)10/16/201810/17/201810/17/2018 8:34:36 AMAPASS
Phone #: ###-#### Inspection requested via web by Chad Uhlorn
PLM17-03132 PLM-Aging Inspection10/17/201810/17/201810/17/2018 6:24:22 AM PASS
PLM17-03132 DOC - Permit Expired10/17/201810/17/201810/17/2018 6:24:13 AMAPASS
PLM17-01099 PLM-Aging Inspection10/17/201810/17/201810/17/2018 6:23:27 AM PASS
PLM17-01099 DOC - Permit Expired10/17/201810/17/201810/17/2018 6:23:18 AMAPASS
PLM18-00105 PLM-Aging Inspection10/17/201810/17/201810/17/2018 6:22:29 AM PART
No calls
PLM18-04249 Plumbing Rough-in10/16/201810/17/201810/16/2018 3:33:06 PMPCANC
JOB # 20018 Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes Inspection cancelled from web by: Ann Marie Reyes