PLM18-04911
| Plumbing Rough-in | 12/11/2018 | 12/12/2018 | 12/12/2018 3:00:49 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
PLM18-04513
| Final | 12/12/2018 | 12/12/2018 | 12/12/2018 2:38:27 PM | P | PASS |
|
|
Please call Brian before entry Phone #: ###-#### Inspection requested via web by Tom Maxwell
|
PLM18-05152
| Groundwork | 12/12/2018 | 12/12/2018 | 12/12/2018 2:25:00 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tom Maxwell
|
PLM18-02639
| Final | 12/12/2018 | 12/12/2018 | 12/12/2018 2:10:20 PM | P | PASS |
|
|
The house is open. Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac
|
PLM18-03304
| Final | 12/12/2018 | 12/12/2018 | 12/12/2018 1:37:10 PM | P | PART |
|
|
Call for access Also a pressure test for gas to range Phone #: ###-#### Inspection requested via web by Brandon Rohricht-20 lb gas test pass. Water heater in crawl needs to be on a level plateform at least 3" above the ground.
|
PLM18-05114
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 1:11:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Grigsby-20 lb gas test pass.
|
PLM18-03486
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 1:05:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Smith
|
PLM18-05155
| Groundwork | 12/11/2018 | 12/12/2018 | 12/12/2018 12:43:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rob Bristol
|
PLM18-04430
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 11:18:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK
|
PLM18-05152
| Groundwork | 12/11/2018 | 12/12/2018 | 12/12/2018 10:56:11 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Tom Maxwell-Can only have 4 fixture units on a 2" horizontal wet vent.
|
PLM18-05130
| Groundwork | 12/11/2018 | 12/12/2018 | 12/12/2018 10:43:49 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers-Need to uncover for inspection.
|
PLM18-05133
| Groundwork | 12/11/2018 | 12/12/2018 | 12/12/2018 10:38:57 AM | A | PASS |
|
|
One of us should be onsite, if not please call me at ###-####. Thanks. Phone #: ###-#### Inspection requested via web by Josh Johnson
|
PLM18-03800
| Final | 12/12/2018 | 12/12/2018 | 12/12/2018 9:40:22 AM | A | PASS |
|
|
Call for access Phone #: ###-#### Inspection requested via web by Brandon Rohricht
|
PLM18-01463
| Final | 12/10/2018 | 12/12/2018 | 12/12/2018 9:30:56 AM | A | PASS |
|
|
Garage code is 1957. Phone #: ###-#### Inspection requested via web by David Stephenson
|
PLM18-05153
| Groundwork | 12/11/2018 | 12/12/2018 | 12/12/2018 9:12:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rob Bristol
|
PLM18-05150
| Sprinkler (Final) | 12/11/2018 | 12/12/2018 | 12/12/2018 8:53:50 AM | A | PASS |
|
|
Sprinkler Backflow- installed on stub installed by plumber through wall Phone #: ###-#### Inspection requested via web by Chad Uhlorn
|
PLM18-05149
| Sprinkler (Final) | 12/11/2018 | 12/12/2018 | 12/12/2018 8:46:16 AM | A | PASS |
|
|
Sprinkler Backflow- installed on stub installed by plumber through wall Phone #: ###-#### Inspection requested via web by Chad Uhlorn
|
PLM18-03229
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 8:29:21 AM | A | NR |
|
|
2124 enter Phone #: ###-#### Inspection requested via web by Ann Marie Reyes-Not ready.
|
PLM18-03227
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 8:28:57 AM | A | PASS |
|
|
1924 enter Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM17-01701
| PLM-Aging Inspection | 12/12/2018 | 12/12/2018 | 12/12/2018 6:17:56 AM | | PASS |
|
|
|
PLM17-01701
| DOC - Permit Expired | 12/12/2018 | 12/12/2018 | 12/12/2018 6:17:44 AM | A | PASS |
|
|
|