PLM18-02351
| Final | 8/22/2018 | 8/27/2018 | 8/27/2018 3:16:40 PM | P | PART |
|
|
Call Rick When on your way ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel-DBCA needs tested and certified. Temp final ok.
|
PLM18-03645
| Final | 8/24/2018 | 8/27/2018 | 8/27/2018 2:55:08 PM | P | PASS |
|
|
*Mechanical Final Also Scheduled* Please inspect in the PM Call on way: Chuck ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
|
PLM18-01234
| Plumbing Rough-in | 8/27/2018 | 8/27/2018 | 8/27/2018 2:51:02 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-DWV & water in area D pass. Need to use mission bands from pvc to cast iron & no-hub bands on pvc to pvc.
|
MEC18-04041
| Pressure Test | 8/24/2018 | 8/27/2018 | 8/27/2018 2:48:02 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves-20 lb gas test pass.
|
MEC18-04041
| Rough-in | 8/24/2018 | 8/27/2018 | 8/27/2018 2:47:30 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves
|
MEC18-02661
| Final | 8/24/2018 | 8/27/2018 | 8/27/2018 2:45:52 PM | P | PASS |
|
|
AC4624 Phone #: ###-#### Inspection requested via web by Gary Reeves
|
MEC18-02473
| Final | 8/24/2018 | 8/27/2018 | 8/27/2018 2:45:38 PM | P | PASS |
|
|
AC;4524 Phone #: ###-#### Inspection requested via web by Gary Reeves
|
MEC18-02471
| Final | 8/24/2018 | 8/27/2018 | 8/27/2018 2:45:22 PM | P | PASS |
|
|
4424 Phone #: ###-#### Inspection requested via web by Gary Reeves
|
PLM18-01976
| Final | 8/27/2018 | 8/27/2018 | 8/27/2018 1:20:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rob Bristol
|
PLM18-03658
| Water and/or Sewer | 8/27/2018 | 8/27/2018 | 8/27/2018 12:54:27 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM18-03658
| DOC - Permit Finaled | 8/27/2018 | 8/27/2018 | 8/27/2018 12:54:17 PM | P | PASS |
|
|
|
PLM18-03659
| Water and/or Sewer | 8/27/2018 | 8/27/2018 | 8/27/2018 12:53:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM18-03659
| DOC - Permit Finaled | 8/27/2018 | 8/27/2018 | 8/27/2018 12:53:48 PM | P | PASS |
|
|
|
PLM18-03654
| Other | 8/27/2018 | 8/27/2018 | 8/27/2018 11:47:18 AM | A | FAIL |
|
|
Backflow Phone #: ###-#### Inspection requested via web by Pat Hurley-Need to use at least 160 psi pipe. Need to grade line from backflow back to main and drain. Retest backflow when complete.
|
PLM18-00304
| Plumbing Rough-in | 8/23/2018 | 8/27/2018 | 8/27/2018 11:28:14 AM | A | FAIL |
|
|
Inspection requested via web by Jeffrey Hankins-Grease trap is undersized per the approved plans. Grease trap is required to have a 3" drain and floor sink. Grease trap is required to have a flow control with a vent. Flow control needs to be accessible. Cannot have a waterline in a 2x4 exterior wall.
|
PLM18-01789
| Water and/or Sewer | 8/27/2018 | 8/27/2018 | 8/27/2018 11:17:50 AM | A | PASS |
|
|
|
PLM18-01789
| DOC - Permit Finaled | 8/27/2018 | 8/27/2018 | 8/27/2018 11:17:43 AM | P | PASS |
|
|
|
PLM18-03615
| Plumbing Rough-in | 8/24/2018 | 8/27/2018 | 8/27/2018 10:31:37 AM | A | FAIL |
|
|
If there are any questions please contact Pat B. at ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann-Test on water fail.
|
PLM18-03348
| Final | 8/23/2018 | 8/27/2018 | 8/27/2018 10:10:00 AM | A | PASS |
|
|
Final on this space only for now. Thanks Phone #: ###-#### Inspection requested via web by Ben Taylor
|
PLM18-03651
| Plumbing Rough-in | 8/26/2018 | 8/27/2018 | 8/27/2018 9:56:46 AM | A | PASS |
|
|
Builder on site. Phone #: ###-#### Inspection requested via web by Troy Pherigo
|
MEC18-02672
| Final | 8/23/2018 | 8/27/2018 | 8/27/2018 9:41:15 AM | A | PASS |
|
|
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
|
MEC18-02673
| Final | 8/23/2018 | 8/27/2018 | 8/27/2018 9:40:59 AM | A | PASS |
|
|
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
|
PLM18-03247
| Final | 8/24/2018 | 8/27/2018 | 8/27/2018 9:15:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige
|
PLM18-03158
| Pressure Test | 8/24/2018 | 8/27/2018 | 8/27/2018 8:53:17 AM | A | PART |
|
|
Gas pipe rough in Phone #: ###-#### Inspection requested via web by RM Mechanical-20 lb gas test inwall only pass.
|
PLM18-02322
| Final | 8/24/2018 | 8/27/2018 | 8/27/2018 8:08:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rob Bristol
|
PLM17-01663
| PLM-Aging Inspection | 8/27/2018 | 8/27/2018 | 8/27/2018 6:14:32 AM | | PART |
|
|
No calls
|
PLM18-00304
| Plumbing Rough-in | 8/23/2018 | 8/27/2018 | 8/23/2018 8:07:28 PM | P | CANC |
|
|
>> Inspection requested via web by Jeffrey Hankins Inspection cancelled from web by: Jeffrey Hankins
|