Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM19-02701 PLM-Aging Inspection7/7/20207/7/20207/8/2020 2:04:42 PM FAIL
tagged
PLM20-02765 Plumbing Rough-in7/6/20207/7/20207/7/2020 3:38:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Kristy Watson
PLM20-02388 Water Heater Final7/7/20207/7/20207/7/2020 3:37:46 PMPPASS
Home is vacant please call Jan she lives next door. ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
PLM20-02630 Water Heater Final7/6/20207/7/20207/7/2020 2:29:41 PMPFAIL
Please call Chelsea with the seasons apartments when en-route. Call technician Steve with any questions or concerns ###-#### Phone #: ###-#### Inspection requested via web by Scott Ferguson
1. need a drip leg on gax line to water heater
2. must use approved materials for t&p cannot use flex to connect t&p to drain
PLM20-02709 Plumbing Rough-in7/6/20207/7/20207/7/2020 1:32:39 PMPNR
Phone #: ###-#### Inspection requested via web by Branden Steers
make sure its ready before calling in again
PLM20-02759 Water Heater Final7/6/20207/7/20207/7/2020 1:16:09 PMPPASS
Homeowner Gary will be home anytime after 1 Phone #: ###-#### Inspection requested via web by Vaughn Carlson
PLM20-02388 Water Heater Final7/1/20207/7/20207/7/2020 10:41:54 AMAFAIL
Home is vacant please call Jan she lives next door, her number is ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Heidi Lukecart
all gasappkiances require a drip leg, cannot re -use gas flex replace with new flex
PLM20-02695 Water Heater Final7/6/20207/7/20207/7/2020 8:41:49 AMAFAIL
Phone #: ###-#### Inspection requested via web by Lynn Mallory
water heayter drain pan must be piped to an approved location, cannot be left open to drain on floor