Inspections for the day of: Friday, December 15, 2017.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-05598 Final12/14/201712/15/201712/15/2017 3:55:24 PMPNR
Phone #: ###-#### Inspection requested via web by Kristin Dolan
MEC17-05603 Final12/14/201712/15/201712/15/2017 3:55:10 PMPFAIL
Phone #: ###-#### Inspection requested via web by Kristin Dolan - Need permanat support under A/C pad
MEC17-05574 Final12/14/201712/15/201712/15/2017 3:20:47 PMPPASS
Customer will be available after 2PM. Please call on way Lonnie ###-####. Phone #: ###-#### Inspection requested via web by Krista Boss
PLM17-04911 Final12/15/201712/15/201712/15/2017 3:20:16 PMPPASS
MEC17-04433 Rough-in12/15/201712/15/201712/15/2017 3:07:58 PMPPASS
Travis Phone #: ###-#### - Okay to cover hard lids in rooms 401-410
MIS17-00236 MEC-Conference12/15/201712/15/201712/15/2017 2:45:28 PMPPART
Temporary occupancy okay, Need to move equipment closer together to fit under hood with 6" clearance to edges, need to extend b-vent for water heater through drop in ceiling
MEC17-05449 Pressure Test12/15/201712/15/201712/15/2017 2:22:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Krista Boss - 20lb gas, 5lb flue x2 pass
MEC17-05449 Rough-in12/15/201712/15/201712/15/2017 2:21:55 PMPFAIL
Phone #: ###-#### Inspection requested via web by Krista Boss - Missing transfer grill in guest bedroom, Ductwork not routed per approved manual J. Need to revise manual J and resubmit for approval
MEC16-01668 Final12/15/201712/15/201712/15/2017 1:39:17 PMPPEND
Final inspection for the podium, elevator lobby, 2nd floor podium bathrooms, and postal room. Please contact Rob ###-#### with questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery - Need approved TCO plan between Anderson and City of Boise, and letter indicating CO sensors have been calibrated and are functioning
MEC16-01668 Rough-in12/15/201712/15/201712/15/2017 1:36:25 PMPPASS
Request for R/I above ceiling inspection managers office. Please contact Rob ###-#### with questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery
MEC17-05422 Final12/14/201712/15/201712/15/2017 9:18:06 AMAFAIL
Flue pressure test. Could the inspector call and let us know what time to meet him there. ###-#### Phone #: ###-#### Inspection requested via web by Devony Bullard - Flue pipe came apart in the chimney when contractor was preparing to pressure test
MEC16-05060 Mec-Aging Inspection12/15/201712/15/201712/15/2017 9:07:29 AM DONE
Expired
MEC16-05060 DOC - Permit Expired12/15/201712/15/201712/15/2017 9:07:16 AMAPASS
MEC16-05062 Mec-Aging Inspection12/15/201712/15/201712/15/2017 9:06:44 AM CANC
MEC17-00624 Mec-Aging Inspection12/15/201712/15/201712/15/2017 9:06:35 AM CANC
MEC16-01668 Final12/15/201712/15/201712/15/2017 8:11:20 AMPCANC
request for final inspection elevator lobby, 2nd floor podium bathrooms and postal room. Please contact Rob ###-#### with questions or concerns. Phone #: ###-#### >> Inspection requested via web by Heather Gransbery Inspection cancelled from web by: Heather Gransbery
MEC16-01668 Final12/15/201712/15/201712/15/2017 8:07:49 AMPCANC
Request for final inspection on 2nd floor podium bathrooms and postal room. Please contact Rob ###-#### with questions or concerns. Phone #: ###-#### >> Inspection requested via web by Heather Gransbery Inspection cancelled from web by: Heather Gransbery