MEC18-01251
| Final | 6/21/2018 | 6/22/2018 | 6/22/2018 4:11:18 PM | P | FAIL |
|
|
Final - call David Phone #: ###-#### Inspection requested via web by Brandon Sorensen - Need drip legs on gas piping for furnace and water heater
|
MEC18-02924
| Pressure Test | 6/21/2018 | 6/22/2018 | 6/22/2018 3:28:42 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Angie Thome - 20lb gas pass
|
MEC18-02924
| Rough-in | 6/21/2018 | 6/22/2018 | 6/22/2018 3:28:22 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Angie Thome - 1) Need approved manual J onsite 2) Fresh air duct can not come from the roof 3) Need a minimum of 4" wide framing on wall with dryer duct so duct isn't smashed 4) Missing nail plates on dryer duct
|
MEC18-02927
| Rough-in | 6/22/2018 | 6/22/2018 | 6/22/2018 3:05:56 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer - Bathroom exhaust not installed per approved plans, need 1" clearance from combustables on b-vent for water heater, Need to support spiral duct work in between joists on the mezzanine in a approved manor.
|
MEC18-02927
| Pressure Test | 6/22/2018 | 6/22/2018 | 6/22/2018 3:04:02 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer - 20lb gas pass on piping to water heater
|
MEC18-02272
| Rough-in | 6/21/2018 | 6/22/2018 | 6/22/2018 3:04:02 PM | P | PASS |
|
|
Rough-in inspection of main corridor, side corridor, woman''s bathroom, and mother''s bathrooms duct work. John Brunnet will be the site contact. Please call 30 minutes prior to arriving on site. ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical - okay to cover
|
MEC18-02921
| Final | 6/21/2018 | 6/22/2018 | 6/22/2018 3:04:02 PM | P | NR |
|
|
Contact: Bob Snow Phone #: ###-#### Inspection requested via web by RM Mechanical
|
MEC18-02283
| Rough-in | 6/22/2018 | 6/22/2018 | 6/22/2018 2:25:33 PM | P | FAIL |
|
|
Rough in on the fourth floor only Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Need to complete installation of line sets in walls
|
MEC18-00928
| Final | 6/22/2018 | 6/22/2018 | 6/22/2018 1:11:55 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak - Need approved supports on PVC flue, and gas piping, need combustion air for mechanical room
|
MEC18-02926
| Final | 6/22/2018 | 6/22/2018 | 6/22/2018 11:43:31 AM | P | PASS |
|
|
We will have all correction taken care of, I will drop by around 11:00 and verify also. Inspection requested via web by Floyd Floyd Peek
|
MEC18-01466
| Final | 6/22/2018 | 6/22/2018 | 6/22/2018 11:01:48 AM | P | PASS |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
|
MEC18-02742
| Final | 6/22/2018 | 6/22/2018 | 6/22/2018 10:41:17 AM | P | PASS |
|
|
extended plumbing vent to 37" above RTU. Strapped gas line in 3 places. Call ahead and I will meet you there. Thank you Phone #: ###-#### Inspection requested via web by jeremy wanders
|
MEC18-02853
| Final | 6/21/2018 | 6/22/2018 | 6/22/2018 10:15:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC18-02669
| Final | 6/18/2018 | 6/22/2018 | 6/22/2018 9:58:47 AM | A | PASS |
|
|
Please call when you are on the way so we can make sure someone is there Phone #: ###-#### Inspection requested via web by Dan McFate
|
MEC18-02213
| Final | 6/15/2018 | 6/22/2018 | 6/22/2018 9:37:41 AM | A | PASS |
|
|
Call customer in route Clive Strong ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
|
MEC18-02477
| Rough-in | 6/20/2018 | 6/22/2018 | 6/22/2018 9:11:27 AM | A | PART |
|
|
Please call Cody when inspector is headed that way. Thank you Phone #: ###-#### Inspection requested via web by Nick Drake Okay to sheetrock hard lids. There is more ductwork to be run once ceilings have been sheetrocked
|
MEC17-04450
| Final | 6/21/2018 | 6/22/2018 | 6/22/2018 9:09:07 AM | A | PASS |
|
|
I thought this had been requested last November. Robin Phone #: ###-#### Inspection requested via web by Robin Cox
|
MEC17-01833
| Mec-Aging Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 6:38:29 AM | | DONE |
|
|
Expired
|
MEC17-01833
| DOC - Permit Expired | 6/22/2018 | 6/22/2018 | 6/22/2018 6:38:14 AM | A | PASS |
|
|
|
MEC17-04528
| Mec-Aging Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 6:37:46 AM | | CANC |
|
|
|
MEC17-04545
| Mec-Aging Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 6:37:07 AM | | CANC |
|
|
|
MEC17-03168
| Mec-Aging Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 6:36:17 AM | | CANC |
|
|
|
MEC17-04543
| Mec-Aging Inspection | 6/22/2018 | 6/22/2018 | 6/22/2018 6:36:06 AM | | CANC |
|
|
|